25 November 2024 in Physica Medica
Objective: By modelling patient exposures of interventional procedures, this study compares the reduction of radiation detriment between Digital Variance Angiography (DVA) and Digital Subtraction Angiography (DSA). Methods: The paper presents a retrospective risk assessment using an in-house developed tool on 107 patient exposures from a clinical trial of DVA used to diagnose peripheral arterial disease (PAD). DICOM exposure parameters were used to initiate the PENELOPE (PENetration and Energy LOss of Positrons and Electrons) Monte Carlo simulation, radiation quality and quantity, and irradiation geometry. The effective dose and the lifetime attributable risk (LAR) for cancer incidence and mortality are calculated based on the International Commission on Radiation Protection's (ICRP) 103 recommendations and the Committee on the Biological Effects of Ionising Radiations' latest (BEIR VII) report, respectively. Results: The study found that procedures conducted using DVA significantly reduce the radiation exposure of patients, compared to DSA. The collective effective dose for the DVA group was 58% lower than that for the DSA group. Correspondingly, the LAR of different organs showed a substantial decrease for cancer incidence (25-75%) and mortality (51-84%). Conclusion: DVA demonstrates a considerable reduction in physical dosimetric quantities and consequently effective dose and cancer risk, suggesting its potential as a safer alternative to DSA in interventional radiology. The use of DVA supports the optimisation of patient radiation protection and aligns with the principles of ALARA (as low as reasonably achievable).
24 July 2025 in Physics in Medicine & Biology
Objective. For quality assurance purposes, one must apply an axial scanning geometry to verify the displayed CT dose index (CTDI) value. This is usually unavailable on newer machines. The multiple scan average dose (MSAD) method was proposed earlier to circumvent this issue, but has not become widespread. Approach. Monte Carlo simulation was combined with its analytical postprocessing to accurately calculate scattering and speed up calculations to investigate several imaging and beam parameter combinations. The calculations were validated by measurements, and the model was used to examine the uncertainty of MSAD caused by an uncontrolled parameter. Main results. By utilizing the periodicity of the MSAD measurement, the uncertainty can be reduced to 0.2%, in contrast to 26.4% in the worst case. The widespread 150 mm long CTDI phantom and the 100 mm long ionization chamber are applicable for the MSAD method and reach 81% efficiency in the estimation of CTDIvol, in contrast to 78% efficiency of the CTDI100 method. Significance. The MSAD measurement with the CTDI setup is slightly more efficient than the CTDI100 measurement protocol. Furthermore, it is applicable both for helical and axial scans, so we recommend the use of direct MSAD measurement for quality assurance in the clinical environment.