Robert L. Hood

Robert L. Hood

Auto-generated profile, based on publicly available information

Robert L. Hood

School of Biomedical Engineering and Sciences, Virginia Tech, Room 325, ICTAS Building, Stanger Street, Blacksburg, VA 24061

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2010 in Journal of Biomechanical Engineering
Verified
Journal Article
Closed access
PDF file
MKMehmet A. Kosoglu
Mehmet A. Kosoglu
RHRobert L. Hood
Robert L. Hood
YCYe Chen
Ye Chen
YXYong Xu
Yong Xu
MRMarissa Nichole Rylander
Marissa Nichole Rylander
CRChristopher G. Rylander
Christopher G. Rylander
Shallow light penetration in tissue has been a technical barrier to the development of light-based methods for in vivo diagnosis and treatment of epithelial carcinomas. This problem can potentially be solved by utilizing minimally invasive probes to deliver light directly to target areas. To develop this solution, fiber optic microneedles capable of delivering light for either imaging or therapy were manufactured by tapering step-index silica-based optical fibers employing a melt-drawing process. Some of the microneedles were manufactured to have sharper tips by changing the heat source during the melt-drawing process. All of the microneedles were individually inserted into ex vivo pig skin samples to demonstrate the feasibility of their application in human tissues. The force on each microneedle was measured during insertion in order to determine the effects of sharper tips on the peak force and the steadiness of the increase in force. Skin penetration experiments showed that sharp fiber optic microneedles that are 3 mm long penetrate through 2 mm of ex vivo pig skin specimens. These sharp microneedles had a minimum average diameter of 73 μm and a maximum tip diameter of 8 μm. Flat microneedles, which had larger tip diameters, required a minimum average diameter of 125 μm in order to penetrate through pig skin samples. Force versus displacement plots showed that a sharp tip on a fiber optic microneedle decreased the skin’s resistance during insertion. Also, the force acting on a sharp microneedle increased more steadily compared with a microneedle with a flat tip. However, many of the sharp microneedles sustained damage during skin penetration. Two designs that did not accrue damage were identified and will provide a basis of more robust microneedles. Developing resilient microneedles with smaller diameters will lead to transformative, novel modes of transdermal imaging and treatment that are less invasive and less painful for the patient.

17 October 2011 in Lasers in Surgery and Medicine
Verified
Journal Article
Closed access
PDF file
MKMehmet A. Kosoglu
Mehmet A. Kosoglu
RHRobert L. Hood
Robert L. Hood
John H. RossmeislJohn H. Rossmeisl
John H. Rossmeisl
DGDavid C. Grant
David C. Grant
YXYong Xu
Yong Xu
CRChristopher G. Rylander
Christopher G. Rylander