Gary Sitbon

Gary Sitbon

Auto-generated profile, based on publicly available information

Gary Sitbon

Lab. de Physique et d’Etude des Matériaux, CNRS, Univ. Pierre et Marie Curie (France)

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 October 2012 in Langmuir
Verified
Journal Article
Closed access
EGEmerson Giovanelli
Emerson Giovanelli
EMEleonora Muro
Eleonora Muro
GSGary Sitbon
Gary Sitbon
MHMohamed Hanafi
Mohamed Hanafi
TPThomas Pons
Thomas Pons
NLNicolas Lequeux
Nicolas Lequeux

20 January 2020
Verified
Other
Open access
FCFred Cook
Fred Cook
RLRachel Lord
Rachel Lord
GSGary Sitbon
Gary Sitbon
ASAdam Stephens
Adam Stephens
ARAlison Rust
Alison Rust
WSWalther Schwarzacher
Walther Schwarzacher

24 March 2014
Verified
Conference Paper
Closed access
EGEmerson Giovanelli
Emerson Giovanelli
EMEleonora Muro
Eleonora Muro
MTMariana Tasso
Mariana Tasso
GSGary Sitbon
Gary Sitbon
MHMohamed Hanafi
Mohamed Hanafi
NLNicolas Lequeux
Nicolas Lequeux
Colloidal fluorescent semiconductor nanocrystals, named “quantum dots”, possess unique features, such as a tunable peak wavelength (according to their composition and their size) or a large absorption cross-section, that make them very attractive for biomedical imaging. Nevertheless, typical syntheses provide nanoparticles capped with hydrophobic ligands. To be used in long-term bioexperiments, they have thus to be modified to exhibit essentially a high colloidal stability in aqueous conditions, but also a low non-specific adsorption, a small size and functionalization moities. As all of these properties are controlled by the layer of coating ligands, we designed a bidentate monozwitterionic ligand, to first address the need of small-sized and antibiofouling hydrophilic probes. But the corresponding quantum dots revealed to be unstable in highly diluted conditions and difficult to functionalize. To further increase the affinity between the nanoparticles and their surrounding ligands, we synthesized a multidentate polyzwitterionic ligand, issued from the copolymerization of a bidentate monomer and a monozwitterionic one. The nanocrystals passivated by this polymeric ligand showed an exceptional colloidal stability, regardless of the medium conditions (pH, salinity, dilution, and biological environment), and we demonstrated the affinity of the polymer exceeded by three orders of magnitude that of the bidentate ligand. The synthesis of the multidentate polyzwitterionic ligand proved also to be easily tunable and allowed the facile introduction of reacting moieties. Further functionalization of the corresponding quantum dots with biomolecules led to successful specific targeting, which could be confirmed, as an example, through FRET experiments.

31 March 2026
Verified
Thesis
Closed access
GSGary Sitbon
Gary Sitbon
La chirurgie guidée par l’imagerie de fluorescence est une technique prometteuse mais limitée par la faible profondeur de pénétration (inférieure au millimètre dans le visible) à cause de l’absorption et de la diffusion par les tissus. Elle est plus élevée dans la gamme du proche infrarouge (700-1000 nm) mais reste limitée à quelques centimètres. L’imagerie par résonance magnétique (IRM) permet d’obtenir des images sur corps entier mais ne peut être utilisée pour le suivi peropératoire. Le développement de sondes bimodales, fluorescentes et magnétiques, permet de coupler les avantages des deux techniques.Nous avons choisi de développer des sondes basées sur des nanocristaux fluorescents de CuIn(S,Se)2 car ils présentent une longueur d’onde d’émission modulable sur toute la gamme du proche infrarouge ainsi que des rendements quantiques, sections efficace d’absorption et photostabilités élevés. La croissance d’une coque épaisse de ZnS permet d’augmenter le rendement quantique qui peut atteindre 60 % dans les solvants organiques. L’incorporation d'ions Mn2+ dans la coque de nos objets permet de leur conférer un caractère paramagnétique. Les propriétés optiques et structurales ont été étudiées par spectroscopie (fluorescence et absorbance), RPE, DRX, MET/METHR et analyse élémentaire. Nos sondes sont transférées en milieu aqueux par un échange de ligands qui ne modifie pas leurs propriétés. Des mesures de relaxivités longitudinales ont permis de confirmer leur potentiel comme agent de contraste pour l’IRM pondérée en T1 et nous avons apporté une preuve de principe de l’utilisation de nos sondes in vivo en marquant des ganglions lymphatiques chez la souris.