Samuel Davis

Samuel Davis

Auto-generated profile, based on publicly available information

Samuel Davis

Caltech Optical Imaging Laboratory, Andrew and Peggy Cherng Department of Medical Engineering, Department of Electrical Engineering, California Institute of Technology, Pasadena, USA

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 September 2022 in Nature Biomedical Engineering
Verified
Journal Article
Closed access
PDF file
Rui CaoRui Cao
Rui Cao
SNScott D. Nelson
Scott D. Nelson
SDSamuel Davis
Samuel Davis
YLYu Liang
Yu Liang
YLYilin Luo
Yilin Luo
LWLihong V. Wang
Lihong V. Wang

1 December 2022 in Nature Photonics
Verified
Journal Article
Closed access
PDF file
Rui CaoRui Cao
Rui Cao
JZJingjing Zhao
Jingjing Zhao
LLLei Li
Lei Li
LDLin Du
Lin Du
Yide ZhangYide Zhang
Yide Zhang
LWLihong V. Wang
Lihong V. Wang

6 August 2019 in Journal of Biophotonics
Verified
Journal Article
Open access
PDF file
SDSamuel P. X. Davis
Samuel P. X. Davis
SKSunil Kumar
Sunil Kumar
YAYuriy Alexandrov
Yuriy Alexandrov
ABAjay Bhargava
Ajay Bhargava
GXGabriela Da Silva Xavier
Gabriela Da Silva Xavier
JMJames McGinty
James McGinty
Optical projection tomography (OPT) is a 3D mesoscopic imaging modality that can utilize absorption or fluorescence contrast. 3D images can be rapidly reconstructed from tomographic data sets sampled with sufficient numbers of projection angles using the Radon transform, as is typically implemented with optically cleared samples of the mm‐to‐cm scale. For in vivo imaging, considerations of phototoxicity and the need to maintain animals under anesthesia typically preclude the acquisition of OPT data at a sufficient number of angles to avoid artifacts in the reconstructed images. For sparse samples, this can be addressed with iterative algorithms to reconstruct 3D images from undersampled OPT data, but the data processing times present a significant challenge for studies imaging multiple animals. We show here that convolutional neural networks (CNN) can be used in place of iterative algorithms to remove artifacts—reducing processing time for an undersampled in vivo zebrafish dataset from 77 to 15 minutes. We also show that using CNN produces reconstructions of equivalent quality to compressed sensing with 40% fewer projections. We further show that diverse training data classes, for example, ex vivo mouse tissue data, can be used for CNN‐based reconstructions of OPT data of other species including live zebrafish.

11 July 2017 in PLOS ONE
Verified
Journal Article
Open access
PDF file
TWThomas Watson
Thomas Watson
NANatalie Andrews
Natalie Andrews
SDSamuel Davis
Samuel Davis
LBLaurence Bugeon
Laurence Bugeon
MDMargaret D. Dallman
Margaret D. Dallman
JMJames McGinty
James McGinty
We describe the implementation of an OPT plate to perform optical projection tomography (OPT) on a commercial wide-field inverted microscope, using our open-source hardware and software. The OPT plate includes a tilt adjustment for alignment and a stepper motor for sample rotation as required by standard projection tomography. Depending on magnification requirements, three methods of performing OPT are detailed using this adaptor plate: a conventional direct OPT method requiring only the addition of a limiting aperture behind the objective lens; an external optical-relay method allowing conventional OPT to be performed at magnifications >4x; a remote focal scanning and region-of-interest method for improved spatial resolution OPT (up to ~1.6 μm). All three methods use the microscope’s existing incoherent light source (i.e. arc-lamp) and all of its inherent functionality is maintained for day-to-day use. OPT acquisitions are performed on in vivo zebrafish embryos to demonstrate the implementations’ viability.

21 November 2025 in Science Advances
Verified
Journal Article
Open access
Byullee ParkByullee Park
Byullee Park
Rui CaoRui Cao
Rui Cao
YLYilin Luo
Yilin Luo
CLCindy Liu
Cindy Liu
YZYushun Zeng
Yushun Zeng
LWLihong V. Wang
Lihong V. Wang
Traditional hematoxylin and eosin staining in formalin-fixed paraffin-embedded sections, while essential for diagnostic pathology, is time-consuming, labor intensive, and prone to artifacts that can obscure critical histological details. Label-free ultraviolet photoacoustic microscopy (UV-PAM) has emerged as a promising alternative, offering fast histology-like images without the need for traditional staining and excessive tissue preparation. However, current UV-PAM systems face challenges in achieving the high spatial resolution required for detailed histological analysis and diagnosis. To address this, we developed a subcellular-resolution UV-PAM (SRUV-PAM) system with a 240-nanometer resolution, enabled by the integration of a high numerical aperture (NA) objective lens (NA = 0.64) and the precise piezo actuators for fine scanning control. This configuration allows visualization of detailed nuclear structures. In addition, we demonstrated virtual staining of SRUV-PAM images via cycle-consistent generative adversarial networks and diagnosis of malignant and benign tumors in liver tissues via densely connected convolutional networks DenseNet-121, achieving an area under the receiver operating characteristic curve of 0.902.

6 November 2018 in Optics Letters
Verified
Journal Article
Open access
PDF file
SDSamuel P. X. Davis
Samuel P. X. Davis
LWLaura Wisniewski
Laura Wisniewski
SKSunil Kumar
Sunil Kumar
TCTeresa Correia
Teresa Correia
SASimon R. Arridge
Simon R. Arridge
PFPaul M. W. French
Paul M. W. French
To improve the imaging performance of optical projection tomography (OPT) in live samples, we have explored a parallelized implementation of semi-confocal line illumination and detection to discriminate against scattered photons. Slice-illuminated OPT (sl-OPT) improves reconstruction quality in scattering samples by reducing interpixel crosstalk at the cost of increased acquisition time. For in vivo imaging, this can be ameliorated through the use of compressed sensing on angularly undersampled OPT data sets. Here, we demonstrate sl-OPT applied to 3D imaging of bead phantoms and live adult zebrafish.