Peng Liu

Peng Liu

Auto-generated profile, based on publicly available information

Peng Liu

Department of Neurosurgery, Beijing Tiantan Hospital, Capital Medical University, Beijing, China

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 January 2023 in Journal of NeuroInterventional Surgery
Verified
Journal Article
Open access
PDF file
SGSiming Gui
Siming Gui
XCXiheng Chen
Xiheng Chen
DWDachao Wei
Dachao Wei
DDDingwei Deng
Dingwei Deng
WYWei You
Wei You
YLYouxiang Li
Youxiang Li
Background: Flow diverters have revolutionized the treatment of intracranial aneurysms. However, the delayed complications associated with flow diverter use are unknown. Objective: To evaluate the incidence, severity, clinical outcomes, risk factors, and dynamic changes associated with in-stent stenosis (ISS) after treatment with a Pipeline embolization device (PED). Methods: Patients who underwent PED treatment between 2015 and 2020 were enrolled. The angiographic, clinical, and follow-up data of 459 patients were independently reviewed by four neuroradiologists to identify ISS. Binary logistic regression was conducted to determine ISS risk factors, and an ISS–time curve was established to demonstrate dynamic changes in ISS after PED implantation. Results: Of the 459 treated patients, 69 (15.0%) developed ISS. At follow-up, nine patients (2.0%) with ISS demonstrated reversal, while 18 (3.9%) developed parental artery occlusion. A total of 380 patients (82.8%) achieved complete aneurysm occlusion (O’Kelly–Marotta grade D). Patients with posterior-circulation aneurysm (OR=2.895, 95% CI (1.732 to 4.838; P54 years (OR=0.464, 95% CI 0.274 to 0.785; P=0.006) or with a body mass index of >28 kg/m2 (OR=0.427, 95% CI 0.184 to 0.991; P=0.026) had a lower ISS risk. Intimal hyperplasia initiated by PED placement peaked within 1 year after the procedure, rarely progressed after 12 months, and tended to reverse within 24 months. Conclusions: ISS is a common, benign, and self-limiting complication of PED implantation in the Chinese population.

21 February 2019 in American Journal of Neuroradiology
Verified
Journal Article
Open access
PDF file
HQHaikun Qi
Haikun Qi
XLX. Liu
X. Liu
PLP. Liu
P. Liu
WYW. Yuan
W. Yuan
ALAihua Liu
Aihua Liu
HCHuijun Chen
Huijun Chen
BACKGROUND AND PURPOSE: Individual assessment of the absolute risk of intracranial aneurysm rupture remains challenging. Emerging imaging techniques such as dynamic contrast-enhanced MR imaging and postcontrast vessel wall MR imaging may improve risk estimation by providing new information on aneurysm wall properties. The purpose of this study was to investigate the relationship between aneurysm wall permeability on dynamic contrast-enhanced MR imaging and aneurysm wall enhancement on postcontrast vessel wall MR imaging in unruptured intracranial aneurysms. MATERIALS AND METHODS: Patients with unruptured saccular intracranial aneurysms were imaged with vessel wall MR imaging before and after gadolinium contrast administration. Dynamic contrast-enhanced MR imaging was performed coincident with contrast injection using 3D T1-weighted spoiled gradient-echo imaging. The transfer constant (Ktrans) was measured adjacent to intracranial aneurysm and adjacent to the normal intracranial artery. RESULTS: Twenty-nine subjects were analyzed (mean age, 53.9 ± 13.5 years; 24% men; PHASES score: median, 8; interquartile range, 4.75–10). Ktrans was higher in intracranial aneurysms compared with the normal intracranial artery (median, 0.0110; interquartile range, 0.0060–0.0390 versus median, 0.0032; interquartile range, 0.0018–0.0048 min−1; P < .001), which correlated with intracranial aneurysm size (Spearman ρ = 0.54, P = .002) and PHASES score (ρ = 0.40, P = .30). Aneurysm wall enhancement, detected in 19 (66%) aneurysms, was associated with intracranial aneurysm size and the PHASES score but not significantly with Ktrans (P = .30). Aneurysms of 2 of the 9 patients undergoing conservative treatment ruptured during 1-year follow-up. Both ruptured aneurysms had increased Ktrans, whereas only 1 had aneurysm wall enhancement at baseline. CONCLUSIONS: Dynamic contrast-enhanced MR imaging showed increased Ktrans adjacent to intracranial aneurysms, which was independent of aneurysm wall enhancement on postcontrast vessel wall MR imaging. Increased aneurysm wall permeability on dynamic contrast-enhanced MR imaging provides new information that may be useful in intracranial aneurysm risk assessment.

19 January 2018 in Interventional Neuroradiology
Verified
Journal Article
Closed access
HGHui Guo
Hui Guo
QYQianKun Yin
QianKun Yin
PLPeng Liu
Peng Liu
NGNing Guan
Ning Guan
XHXiaochuan Huo
Xiaochuan Huo
YLYouxiang Li
Youxiang Li
Transvenous embolization (TVE) is widely utilized as an effective and safe treatment option for cavernous sinus dural arteriovenous fistula (CS-dAVF); however, detecting the exact location of the fistula is challenging. The present study identified the angiographic features of the fistulous point and evaluated the match with the microcatheter tip and fistulous point. An analysis cohort of 45 consecutive patients with CS-dAVF treated by TVE was analyzed retrospectively. The patients were divided into two groups, 22 matches and 23 mismatches, according to whether the fistulous point and the microcatheter tip were in the same compartment of the cavernous sinus (CS). The angiographic findings, the location of the fistulas, the position of the microcatheter tips, the volume of embolic materials, complications, and outcomes were assessed. Several angiographic features defined the fistulous points, such as the early opacified area, jellyfish-like sign, changes in the density of the contrast medium, the juncture of different arterial supply, enlarged feeders, and hand-injection angiograms. The fistulas were primarily in the posterosuperior portion of the CS (80%) and medial side (73.3%) according to the internal carotid artery. Both groups achieved effective TVE; the matched group required less embolic material than the mismatched group (p = 0.024). The patients with cranial nerve dysfunction (CND) required more embolic materials than others (p = 0.032). The fistulous point in most of the CS-dAVFs could be isolated by careful analysis of the angiography images. The matching of the microcatheter tip and fistulous point in the same compartment of CS can reduce the dosage of embolic materials, and a low volume of embolic materials might cause fewer CND complications.

2 September 2020 in Interventional Neuroradiology
Verified
Journal Article
Closed access
PDF file
PLPeng Liu
Peng Liu
XCXiheng Chen
Xiheng Chen
WYWei You
Wei You
YLYouxiang Li
Youxiang Li
MLMing Lv
Ming Lv
XLXianli Lv
Xianli Lv
Background and purpose: Hemorrhagic complication is a disastrous complication of intracranial dural arteriovenous fistulas (DAVFs) embolization. This study was to analyze the possible risk factors for the hemorrhagic complication caused by endovascular embolization of DAVFs. Methods: From January 2012 to July 2016, a total of 267 patients with intracranial DAVFs received endovascular Onyx embolization at our hospital. The demographic information, clinical presentation, angiographic features, endovascular treatment and hemorrhagic complications were reviewed. Univariate and multivariate logistic regression analyses were performed to evaluate the risk factors contributing to the post-procedural hemorrhagic complications. Results: In 267 patients of DAVF treated with endovascular embolization, procedure-related hemorrhagic complication occurred in 12 (4.5%) patients. Univariate and multivariate logistic regression analyses showed that the pial arterial supplier (OR 13.630; 95% CI, 1.556–119.368; P = 0.018), giant venous aneurysm (OR 15.196; 95% CI, 2.505–92.183; P = 0.003) and Onyx volume ≥ 6 ml (OR 1.138; 95% CI, 1.006–1.288; P = 0.040) were significant factors associated with these hemorrhagic complications. Conclusions: Hemorrhagic complications associated with endovascular DAVF embolization are not negligible. The pial arterial supplier, giant venous aneurysm and higher Onyx volume in one session may be risk factors for endovascular DAVF embolization.

25 May 2023 in Journal of NeuroInterventional Surgery
Verified
Journal Article
Closed access
PDF file
CWChao Wang
Chao Wang
LDLinggen Dong
Linggen Dong
JLJian Liu
Jian Liu
YZYisen Zhang
Yisen Zhang
KWKun Wang
Kun Wang
YZYing Zhang
Ying Zhang
Background Stent assisted coiling (SAC) and flow diverters (FDs) are common endovascular treatments for wide necked cerebral aneurysms, but studies comparing the new generation Atlas SAC and FDs are scarce. We performed a propensity score matched (PSM) cohort study to compare the Atlas SAC and the pipeline embolization device (PED) for proximal internal carotid artery (ICA) aneurysms. Methods Consecutive ICA aneurysms treated at our institution with either the Atlas SAC or PED were studied. PSM was used to control for age, sex, smoking, hypertension, and hyperlipidemia, and the rupture status, maximal diameter, and neck size of the aneurysm (aneurysms >15 mm and non-saccular aneurysms were excluded). Midterm outcomes and hospital costs were compared between these two devices. Results A total of 309 patients with 316 ICA aneurysms were included. Following PSM, 178 aneurysms treated with the Atlas SAC and PED were matched (n=89 in each group). Aneurysms treated with the Atlas SAC required a slightly longer procedure time, but had lower hospital costs than those treated with the PED (115.2±24.6 vs 102.4±40.8 min, P=0.012; $27 650.2±$6961.4 vs $34 107.0±$3707.2, P<0.001). Atlas SAC and PED treatments showed equivalent aneurysm occlusion rates (89.9% vs 86.5%, P=0.486), complication rates (5.6% vs 11.2%, P=0.177), and a favorable functional outcome (96.6% vs 97.8%, P=1.0) at follow-up (8.2±3.0 vs 8.4±4.2 months, P=0.652). Conclusion In this PSM study, midterm outcomes of the PED and Atlas SAC in the treatment of ICA aneurysms were similar. However, SAC required a longer operation time, and the PED may increase the economic cost of inpatients in Beijing, China.

20 February 2025 in Journal of NeuroInterventional Surgery
Verified
Journal Article
Closed access
PDF file
KTKe Tian
Ke Tian
ZCZhenyao Chang
Zhenyao Chang
YYYi Yang
Yi Yang
PLPeng Liu
Peng Liu
MMMahmud Mossa-Basha
Mahmud Mossa-Basha
YXYuanqing Xia
Yuanqing Xia
Background Artificial intelligence can help to identify irregular shapes and sizes, crucial for managing unruptured intracranial aneurysms (UIAs). However, existing artificial intelligence tools lack reliable classification of UIA shape irregularity and validation against gold-standard three-dimensional rotational angiography (3DRA). This study aimed to develop and validate a deep-learning model using computed tomography angiography (CTA) for classifying irregular shapes and measuring UIA size. Methods CTA and 3DRA of UIA patients from a referral hospital were included as a derivation set, with images from multiple medical centers as an external test set. Senior investigators manually measured irregular shape and aneurysm size on 3DRA as the ground truth. Convolutional neural network (CNN) models were employed to develop the CTA-based model for irregular shape classification and size measurement. Model performance for UIA size and irregular shape classification was evaluated by intraclass correlation coefficient (ICC) and area under the curve (AUC), respectively. Junior clinicians’ performance in irregular shape classification was compared before and after using the model. Results The derivation set included CTA images from 307 patients with 365 UIAs. The test set included 305 patients with 350 UIAs. The AUC for irregular shape classification of this model in the test set was 0.87, and the ICC of aneurysm size measurement was 0.92, compared with 3DRA. With the model’s help, junior clinicians’ performance for irregular shape classification was significantly improved (AUC 0.86 before vs 0.97 after, P<0.001). Conclusion This study provided a deep-learning model based on CTA for irregular shape classification and size measurement of UIAs with high accuracy and external validity. The model can be used to improve reader performance.