Current harmonics will produce losses, which make motor heated. The high temperature of the motor applied to turbo molecular pump (TMP) will degrade ultrahigh vacuum performance severely. Current harmonics should be suppressed effectively. The repetitive controller (RC) has been widely used in harmonic suppression. To address key challenges of conventional RC, this article proposes a novel virtual even-order fractional RC. First, the virtual fundamental frequency is introduced and the even-order RC is constructed. Second, the Lagrange interpolation is designed to fit the fractional part of the delay coefficient. Then, the low-pass filter (LPF) is replaced by a finite impulse response (FIR) filter and is removed out of RC internal model. The proposed method can improve the convergence speed of harmonic suppression. The tracking deviation in the high-frequency band is reduced and the harmonic suppression accuracy is improved. Finally, the effectiveness of the method is verified on the high-speed magnetically suspended TMP.
16 June 2025 in IEEE Transactions on Industrial Informatics
Current measurement error (CME) could lead to large torque ripple, increased losses, and reduced control performance. The long-term operation under heavy load of magnetic levitation turbo molecular pumps (MLTMPs) makes their core component–the permanent magnet synchronous motor (PMSM)–particularly susceptible to CME, thereby reducing ultrahigh vacuum performance. This article introduces a novel method for correcting CME in PMSMs by analyzing phase current harmonics, which addresses the issue of traditional methods ignoring phase current distortion. First, a control model under the CME conditions is proposed, utilizing a Proportional Integral Resonant controller to mitigate periodic disturbances. Second, the quantitative relationship between the CME and phase currents is derived through harmonic analysis based on the proposed control model. Then, an improved synchronous frequency extractor is employed for the extraction and compensation of the CME. This method features ease of application, independence from motor parameters, and good real-time performance. Finally, experiments on MLTMPs validate the effectiveness of the proposed approach.
3 June 2026 in IEEE Transactions on Industrial Electronics
Low-inductance permanent magnet sync hronous motors (PMSMs) are prone to significant high-frequency current harmonics when driven by pulse-width modulation (PWM) inverters. In magnetically levitated turbomolecular pump (MLTMP) applications, these harmonics lead to increased losses, temperature rise, torque ripple, and may even deteriorate magnetic bearing stability. To address this issue, an adaptive DC bus voltage modulation strategy based on extremum seeking control and cascaded deadbeat predictive control (ESC-CDPC) is proposed. A front-end buck converter is employed to enable variable bus voltage, and a model-free ESC algorithm continuously generates the optimal voltage reference by minimizing a composite cost function balancing efficiency and modulation constraints. The CDPC algorithm ensures fast and low-complexity voltage tracking, while time-scale separation guarantees stable coordinated operation. Compared with conventional fixed and dynamic voltage schemes, the proposed strategy optimizes voltage utilization and achieves source-level suppression of high-frequency harmonics. Experimental results show that the current total harmonic distortion decreases from 49.55% and 28.59% to 17.92%, the winding and housing temperatures drop by 4.4 and 3.5 ${}^\boldsymbol{\circ}$ C, and the input power is reduced, demonstrating improved energy efficiency and performance of MLTMP systems.