Karthikeyan Baskaran

Karthikeyan Baskaran

Auto-generated profile, based on publicly available information

Karthikeyan Baskaran

Department of Medicine and Optometry, Linnaeus University, Kalmar, Sweden

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 March 2021 in Clinical and Experimental Optometry
Verified
Journal Article
Open access
PDPelsin Demir
Pelsin Demir
KBKarthikeyan Baskaran
Karthikeyan Baskaran
BTBaskar Theagarayan
Baskar Theagarayan
PGPeter Gierow
Peter Gierow
PSPadmaja Sankaridurg
Padmaja Sankaridurg
AMAntonio Filipe Macedo
Antonio Filipe Macedo
Clinical relevance: Investigation of refractive errors amongst Swedish schoolchildren will help identify risk factors associated with myopia development.Background: Genetic and hereditary aspects have been linked with the development of myopia. Nevertheless, in the case of ‘school myopia’ some authors suggest that environmental factors may affect gene expression, causing school myopia to soar. Additional understanding about which environmental factors play a relevant role can be gained by studying refractive errors in countries like Sweden, where prevalence of myopia is expected to be low.Methods: Swedish schoolchildren aged 8-16 years were invited to participate. Participants underwent an eye examination, including cycloplegic refraction and axial length (AL) measurements. Predictors such as time spent in near work, outdoor activities and parental myopia were obtained using a questionnaire. Myopia was defined as spherical equivalent refraction (SER) ≤ −0.50D and hyperopia as SER ≥ +0.75D.Results: A total of 128 children (70 females and 58 males) participated in this study with mean age of 12.0 years (SD = 2.4). Based on cycloplegic SER of the right eye, the distribution of refractive errors was: hyperopia 48.0% (CI95 = 38.8-56.7), emmetropia 42.0% (CI95 = 33.5-51.2) and myopia 10.0%. (CI95 = 4.4-14.9). The mean AL was 23.1 mm (SD = 0.86), there was a correlation between SER and AL, r = −0.65 (p < 0.001). Participants with two myopic parents had higher myopia and increased axial length than those with one or no myopic parents. The mean time spent in near work, outside of school, was 5.3 hours-per-day (SD = 3.1), and mean outdoor time reported was 2.6 hours-per-day (SD = 2.2) for all the participants. The time spent in near work and outdoor time were different for different refractive error categories.Conclusion: The prevalence of myopia amongst Swedish schoolchildren is low. Hereditary and environmental factors are associated with refractive error categories. Further studies with this sample are warranted to investigate how refractive errors and environmental factors interact over time.

1 April 2007 in Investigative Ophthalmology & Visual Science
Verified
Journal Article
Open access
PDF file
SBShrikant R. Bharadwaj
Shrikant R. Bharadwaj
MHM. Pia Hoenig
M. Pia Hoenig
VSViswanathan C. Sivaramakrishnan
Viswanathan C. Sivaramakrishnan
BKBaskaran Karthikeyan
Baskaran Karthikeyan
DSDonna Simonian
Donna Simonian
CSClifton M. Schor
Clifton M. Schor
Purpose. The maximum binocular vertical disparity that can be fused with disparity vergence (vertical-fusion amplitude or VFA), varies with convergence angle. VFA is larger for convergence responses to near than to far viewing distances; however, the clinical norms for changes in VFA with convergence have not been established. VFA at several convergence angles was measured to obtain a quantitative description of the changes in VFA with convergence. methods. Fifty-six adults took part in the study. Horizontal and vertical disparity stimuli were presented on a computer monitor by using the red-green anaglyphic technique. Stimulus to convergence was altered either by changing horizontal disparity on the computer monitor (experiment I: nine horizontal disparities: 1.2–22.5 PD [Δ]) or by changing the binocular viewing distance (experiment II: five viewing distances: 25–300 cm). Convergence was held constant during an experimental session, while vertical disparity was incremented in steps of 0.05 Δ after a subjective report of fusion, until the subject reported diplopia. The maximum vertical disparity that could be fused was defined as the VFA. results. VFA increased linearly over the range of convergence stimuli (y = 0.10x + 1.62) and intersubject variability of VFA increased marginally with the amount of convergence. Linear regression equations with similar slopes and y-intercepts were observed in experiments I and II. conclusions. The results of the experiments provide a quantitative description of a linear relationship between VFA and convergence. The linear regression equation could be used in a clinical setting to establish norms and to screen for vertical vergence abnormalities.

22 July 2018 in Scandinavian Journal of Optometry and Visual Science
Verified
Journal Article
Open access
PDF file
AMAntonio Miguel Miranda
Antonio Miguel Miranda
ENEduardo J Nunes-Pereira
Eduardo J Nunes-Pereira
KBKarthikeyan Baskaran
Karthikeyan Baskaran
AMAntonio Filipe Macedo
Antonio Filipe Macedo
This study investigated the use of eye-tracking glasses to monitor visual behaviour when reading from electronic devices and paper in free-viewing conditions. The Tobii-Pro-Glasses were used to monitor 20 subjects with normal vision during reading tasks. Reading was performed in a smartphone, computer, paper and tablet. Texts from the IReST-test were read in devices in a random order. Participants read one text in each device and then repeated the same task 1 hour later; in total each participant read eight different texts. The sequence for the devices was randomized. We found differences between devices for saccade amplitude, fixation duration, convergence distance and pupil size. Reading speed between computer and tablet was slightly different (8 words-per-minute) and pupil size reduced up to 20% in electronic devices compared to print. Behavioural changes observed whilst reading from different devices may reflect an attempt from readers to optimize performance. The need to maintain visual performance under different visual condition may lead to increased visual symptoms. Eye-tracking glasses could be a valuable tool to investigate visual aspects of digital strain.

1 September 2012 in Optometry and Vision Science
Verified
Journal Article
Closed access
KBKarthikeyan Baskaran
Karthikeyan Baskaran
RRRobert Rosén
Robert Rosén
PLPeter Lewis
Peter Lewis
PUPeter Unsbo
Peter Unsbo
JGJörgen Gustafsson
Jörgen Gustafsson

7 June 2019 in PLOS ONE
Verified
Journal Article
Open access
PDF file
KBKarthikeyan Baskaran
Karthikeyan Baskaran
AMAntonio Filipe Macedo
Antonio Filipe Macedo
Yingchen HeYingchen He
Yingchen He
LHLaura Hernandez-Moreno
Laura Hernandez-Moreno
TQTatiana Queirós
Tatiana Queirós
ACAurélie Calabrèse
Aurélie Calabrèse
First, to evaluate inter-rater reliability when human raters estimate the reading performance of visually impaired individuals using the MNREAD acuity chart. Second, to evaluate the agreement between computer-based scoring algorithms and compare them with human rating. Reading performance was measured for 101 individuals with low vision, using the Portuguese version of the MNREAD test. Seven raters estimated the maximum reading speed (MRS) and critical print size (CPS) of each individual MNREAD curve. MRS and CPS were also calculated automatically for each curve using two different algorithms: the original standard deviation method (SDev) and a non-linear mixed effects (NLME) modeling. Intra-class correlation coefficients (ICC) were used to estimate absolute agreement between raters and/or algorithms. Absolute agreement between raters was ‘excellent’ for MRS (ICC = 0.97; 95%CI [0.96, 0.98]) and ‘moderate’ to ‘good’ for CPS (ICC = 0.77; 95%CI [0.69, 0.83]). For CPS, inter-rater reliability was poorer among less experienced raters (ICC = 0.70; 95%CI [0.57, 0.80]) when compared to experienced ones (ICC = 0.82; 95%CI [0.76, 0.88]). Absolute agreement between the two algorithms was ‘excellent’ for MRS (ICC = 0.96; 95%CI [0.91, 0.98]). For CPS, the best possible agreement was found for CPS defined as the print size sustaining 80% of MRS (ICC = 0.77; 95%CI [0.68, 0.84]). Absolute agreement between raters and automated methods was ‘excellent’ for MRS (ICC = 0.96; 95% CI [0.88, 0.98] for SDev; ICC = 0.97; 95% CI [0.95, 0.98] for NLME). For CPS, absolute agreement between raters and SDev ranged from ‘poor’ to ‘good’ (ICC = 0.66; 95% CI [0.3, 0.80]), while agreement between raters and NLME was ‘good’ (ICC = 0.83; 95% CI [0.76, 0.88]). For MRS, inter-rater reliability is excellent, even considering the possibility of noisy and/or incomplete data collected in low-vision individuals. For CPS, inter-rater reliability is lower. This may be problematic, for instance in the context of multisite investigations or follow-up examinations. The NLME method showed better agreement with the raters than the SDev method for both reading parameters. Setting up consensual guidelines to deal with ambiguous curves may help improve reliability. While the exact definition of CPS should be chosen on a case-by-case basis depending on the clinician or researcher’s motivations, evidence suggests that estimating CPS as the smallest print size sustaining about 80% of MRS would increase inter-rater reliability.

30 October 2018 in Journal of the Optical Society of America A
Verified
Journal Article
Closed access
PDF file
MAMuhammad Nadeem Akram
Muhammad Nadeem Akram
RBRigmor C. Baraas
Rigmor C. Baraas
KBKarthikeyan Baskaran
Karthikeyan Baskaran
There is a need to better understand the peripheral optics of the human eye and their correction. Current eye models have some limitations to accurately predict the wavefront errors for the emmetropic eye over a wide field. The aim here was to develop an anatomically correct optical model of the human eye that closely reproduces the wavefront of an average Caucasian-only emmetropic eye across a wide visual field. Using an optical design program, a schematic eye was constructed based on ocular wavefront measurements of the right eyes of thirty healthy young emmetropic individuals over a wide visual field (from 40° nasal to 40° temporal and up to 20° inferior field). Anatomical parameters, asymmetries, and dispersion properties of the eye’s different optical components were taken into account. A geometry-independent gradient index model was employed to better represent the crystalline lens. The RMS wavefront error, wavefront shapes, dominant Zernike coefficients, nasal-temporal asymmetries, and dispersion properties of the developed schematic eye closely matched the corresponding measured values across the visual field. The developed model can help in the design of wide-field ophthalmic instruments and is useful in the study and simulations of the peripheral optics of the human eye.