31 July 2018 in IEEE Transactions on Biomedical Circuits and Systems
In this paper, we present the design, the implementation and the validation of a novel Internet of Things (IoT) drug monitoring system for the online continuous and simultaneous detection of two main anesthetics, e.g., propofol and paracetamol, in undiluted human serum. The described full system consists of a custom-built electronic Raspberry Pi (RPi) based Printed Circuit Board (PCB) that drives and reads out the signal from an electrochemical sensing platform integrated into a fluidic system. Thanks to the Polydimethylsiloxane (PDMS) fluidic device, the analyzed sample is automatically fluxed on the sensing site. The IoT network is supported by a Cloud system, which allows the doctor to control and share all the patient's data through a dedicated Android application and a smart watch. The validation closes with the first ever demonstration that our system successfully works for the simultaneous monitoring of propofol and paracetamol in undiluted human serum by measuring the concentration trends of these two drugs in fluxing conditions over time.
20 April 2018 in IEEE Sensors Journal
Nano-materials are highly exploited to enhance sensing performance of electrochemical electrodes by increasing the Electro-Active Surface Area (EASA). In this work, an analytical calculation of the deposited EASA is presented and experimentally validated by comparing two kinds of nanostructured electrochemical sensors modified with Multi-Walled Carbon Nano-Tubes (MWCNTs) and fullerenes. Further, the two differently nano-structured electrodes, prepared with equal optimum EASA, have been adopted as novel approach in the detection of Paracetamol (APAP) and Midazolam (MZ), two largely adopted and complementary sedative drugs. We have used the novel approach to let emerge the different nano-scale structures’ sensing performance at the same equivalent EASA. The analytical method for EASA calculation has been recently validated by our group on different nano-materials; hence the aim of the actual work is to present, for the first time, its efficient applicability also in comparing the performance of different allotropes of the same nature (carbon-based) in drug sensing, e.g. MZ and APAPA. Our study also includes the comparison in undiluted Human Serum (HS), proposed here as complex biosample, to confirm the validity of our novel approach close to real applications. With respect to Fullerenes, the MWCNTs-modified electrodes obtained the best LOD values in HS detection, as 0.3518 μM and 0.5367 mM for APAP and MZ, respectively. Scanning Electron Microscopy (SEM) analysis also confirmed the higher quality of MWCNTs-based surface in terms of homogeneity and denser coverage of the surface with respect to fullerene-based one, with a better-packed aggregate of assembled structures.
8 March 2018 in Electroanalysis
18 May 2020 in IEEE Transactions on Nanobioscience
The fast widening of biosensing applications, such as healthcare, drug delivery, food, and military industries, is increasing the need for generality and compatibility among different sensors. To address this challenge, we present here an innovative approach for the fast development of new electronic biosensing systems, linking a custom-designed front-end with a multi-purpose system. We envision an open tool to help designers to focus on the target molecule and related detection method instead of designing each time a dedicated electronic device. The architecture of the proposed system is based on a modular approach, where only the front-end and the software need to be custom re-designed according to the application. Considering current research and applying a rigorous definition of the technical requirements, the core of the system is designed to fit the highest number of biosensing methods. The flexibility of this approach is successfully demonstrated with three different types of biosensors, i.e., amperometric, ion-sensitive, and memristive.
1 September 2018 in Integration