Antony P. McNamee

Antony P. McNamee

Auto-generated profile, based on publicly available information

Antony P. McNamee

Biorheology Research Laboratory, Griffith University 1 , Gold Coast

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 May 2022 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
HAOTIAN CHAHAOTIAN CHA
HAOTIAN CHA
Hedieh FallahiHedieh Fallahi
Hedieh Fallahi
YDYuchen Dai
Yuchen Dai
SYSharda Yadav
Sharda Yadav
SHSamith Hettiarachchi
Samith Hettiarachchi
JZJun Zhang
Jun Zhang
Inertial microfluidics functions solely based on the fluid dynamics at relatively high flow speed. Thus, channel geometry is the critical design parameter that contributes to the performance of the device. Four basic channel geometries (i.e., straight, expansion-contraction, spiral and serpentine) have been proposed and extensively studied. To further enhance the performance, innovative channel design through combining two or more geometries is promising. This work explores embedding periodic concave and convex obstacle microstructures in sinusoidal channels and investigates their influence on particle inertial focusing and separation. The concave obstacles could significantly enhance the Dean flow and tune the flow range for particle inertial focusing and separation. Based on this finding, we propose a cascaded device by connecting two sinusoidal channels consecutively for rare cell separation. The concave obstacles are embedded in the second channel to adapt its operational flow rates and enable the functional operation of both channels. Polystyrene beads and breast cancer cells (T47D) spiking in the blood were respectively processed by the proposed device. The results indicate an outstanding separation performance, with 3 to 4 orders of magnitude enhancement in purity for samples with a primary cancer cells ratio of 0.01% and 0.001%, respectively. Embedding microstructures as obstacles brings more flexibility to the design of inertial microfluidic devices, offering a feasible new way to combine two or more serial processing units for high-performance separation.

14 March 2023 in Transfusion Medicine Reviews
Verified
Journal Article
Closed access
AMAntony P. McNamee
Antony P. McNamee
MSMichael Simmonds
Michael Simmonds

6 September 2017 in Artificial Organs
Verified
Journal Article
Closed access
PDF file
AMAntony P. McNamee
Antony P. McNamee
Jarod HorobinJarod Horobin
Jarod Horobin
GTGeoff D. Tansley
Geoff D. Tansley
MSMichael Simmonds
Michael Simmonds

1 August 2020 in Microcirculation
Verified
Journal Article
Open access
PDF file
AMAntony P. McNamee
Antony P. McNamee
GTGeoff D. Tansley
Geoff D. Tansley
MSMichael Simmonds
Michael Simmonds
Blood exposure to supraphysiological shear stress within mechanical circulatory support is suspected of reducing red blood cell (RBC) deformability and being primal in the pathogenesis of several secondary complications. No prior works have explored RBC dynamics with the resolution required to determine shear elastic modulus, and/or cell capillary velocity, following exposure to mechanical stresses. Healthy RBCs were exposed to 0, 5, 50, and 100 Pa in a Couette shearing system. For comparison, blood was also exposed to heat treatment—a method that predictably increases RBC rigidity. Shear modulus assessment required aspiration of single RBCs through narrow micropipettes at known suction force. Cell transit velocities were measured within microchannels in regions of fully developed flow. Supraphysiological shear stress increased the elastic shear modulus by 39% and 69% following exposure to 50 and 100Pa, respectively. Cell transit velocity, however, did not change following shear, with concurrent decreases in cell volume likely nullifying increased shear modulus‐friction interactions. Differences observed were consistent with our internal control (heat treatment), supporting that cell mechanics are significantly impaired following supraphysiological‐sublethal shear exposure. Given mechanical circulatory support operates at shear stresses consistent with the present study, it is plausible that these devices induce fundamental impairment to the material properties of RBCs.

1 November 2018 in Microvascular Research
Verified
Journal Article
Open access
AMAntony P. McNamee
Antony P. McNamee
GTGeoff D. Tansley
Geoff D. Tansley
MSMichael J. Simmonds
Michael J. Simmonds
Circulation of blood depends, in part, on the ability of red blood cells (RBCs) to aggregate, disaggregate, and deform. The primary intrinsic disaggregating force of RBCs is derived from their electronegativity, which is largely determined by sialylated glycoproteins on the plasma membrane. Given supraphysiological shear exposure - even at levels below those which induce hemolysis - alters cell morphology, we hypothesized that exposure to supraphysiological and subhemolytic shear would cleave membrane-bound sialic acid, altering the electrochemical and physical properties of RBCs, and thus increase RBC aggregation. Isolated RBCs from healthy donors (n = 20) were suspended in polyvinylpyrrolidinone. Using a Poiseuille shearing system, RBC suspensions were exposed to 125 Pa for 1.5 s for three duty-cycles. Following the first and third shear duty-cycle, samples were assessed for: RBC aggregation; the ability of RBCs to aggregate independent of plasma ("aggregability"); disaggregation shear rate; membrane-bound sialic acid content, and; cell electrophoretic mobility. Initial shear exposure significantly increased RBC aggregation, aggregability, and the shear required for rouleaux dispersion. Sialic acid concentration significantly decreased on isolated RBC membranes ghosts, and increased in the supernatant following shear. Initial shear exposure decreased the electrophoretic mobility of RBCs, decreasing the electronegative charge from -15.78 ± 0.31 to -7.55 ± 0.21 mV. Three exposures to the shear duty-cycle did not further compound altered RBC measures. A single exposure to supraphysiological and subhemolytic shear significantly decreased the electrochemical charge of the RBC membrane, concurrently increasing cell aggregation/aggregability. The cascading implications of hyperaggregation appears to potentially explain the ischemia-associated complications commonly reported following mechanical circulatory support.

29 August 2024 in Proceedings of the National Academy of Sciences
Verified
Journal Article
Open access
LKLennart Kuck
Lennart Kuck
AMAntony P. McNamee
Antony P. McNamee
MBMaria Bordukova
Maria Bordukova
ASArio Sadafi
Ario Sadafi
CMCarsten Marr
Carsten Marr
MSMichael Simmonds
Michael Simmonds
Hematopoietic stem cells surrender organelles during differentiation, leaving mature red blood cells (RBC) devoid of transcriptional machinery and mitochondria. The resultant absence of cellular repair capacity limits RBC circulatory longevity, and old cells are removed from circulation. The specific age-dependent alterations required for this apparently targeted removal of RBC, however, remain elusive. Here, we assessed the function of Piezo1, a stretch-activated transmembrane cation channel, within subpopulations of RBC isolated based on physical properties associated with aging. We subsequently investigated the potential role of Piezo1 in RBC removal, using pharmacological and mechanobiological approaches. Dense (old) RBC were separated from whole blood using differential density centrifugation. Tolerance of RBC to mechanical forces within the physiological range was assessed on single-cell and cell population levels. Expression and function of Piezo1 were investigated in separated RBC populations by monitoring accumulation of cytosolic Ca 2+ and changes in cell morphology in response to pharmacological Piezo1 stimulation and in response to physical forces. Despite decreased Piezo1 activity with increasing cell age, tolerance to prolonged Piezo1 stimulation declined sharply in older RBC, precipitating lysis. Cell lysis was immediately preceded by an acute reversal of density. We propose a Piezo1-dependent mechanism by which RBC may be removed from circulation: Upon adherence of these RBC to other tissues, they are uniquely exposed to prolonged mechanical forces. The resultant sustained activation of Piezo1 leads to a net influx of Ca 2+ , overpowering the Ca 2+ -removal capacity of specifically old RBC, which leads to reversal of ion gradients, dysregulated cell hydration, and ultimately osmotic lysis.