17 November 2020 in Physical Review Research
Water mediates electrostatic interactions via the orientation of its dipoles around ions, molecules, and interfaces. This induced water polarization consequently influences multiple phenomena. In particular, water polarization affects ion adsorption and transport, biomolecular self-assembly, and surface chemical reactions. Therefore, it is of paramount importance to understand water-mediated interactions modulated by nanoconfinement at the nanoscale. Here we investigate the effective interaction between two oppositely charged ions in different positions in water confined between two graphene surfaces. We find that the attraction between physisorbed ions is enhanced in the surface normal direction while the in-plane interaction is almost unaffected. The attraction in the surface normal direction is further enhanced by decreasing the confinement distance. Conversely, when one ion is intercalated into the graphene layers, the interaction becomes repulsive. Moreover, upon exchange of the ions' positions along the surface normal direction, the interaction energy changes by about . The nonequivalent and directional properties found here, referred to as nonreciprocal interactions, cannot be explain by current water permittivity models in confinement. Our x-ray reflectivity experiments of the water structure near a graphene surface support our molecular dynamics simulation results. Our work shows that the water structure is not enough to infer electrostatic interactions near interfaces.
17 October 2018 in The Journal of Physical Chemistry C
28 August 2015 in Scientific Reports
X-ray phase-contrast imaging is a promising approach for improving soft-tissue contrast and lowering radiation dose in biomedical applications. While current tabletop imaging systems adapt to common x-ray tubes and large-area detectors by employing absorptive elements such as absorption gratings or monolithic crystals to filter the beam, we developed nanometric phase gratings which enable tabletop x-ray far-field interferometry with only phase-shifting elements, leading to a substantial enhancement in the performance of phase contrast imaging. In a general sense the method transfers the demands on the spatial coherence of the x-ray source and the detector resolution to the feature size of x-ray phase masks. We demonstrate its capabilities in hard x-ray imaging experiments at a fraction of clinical dose levels and present comparisons with the existing Talbot-Lau interferometer and with conventional digital radiography.
23 May 2022 in Materials for Quantum Technology
Silicon carbide (SiC) can be synthesized in a number of different structural forms known as polytypes with a vast array of optically active point defects of interest for quantum information sciences. The ability to control and vary the polytypes during SiC synthesis may offer a powerful methodology for the formation of new material architectures that expand our ability to manipulate these defects, including extending coherence lifetimes and enhancing room temperature operation. Polytypic control during synthesis presents a significant challenge given the extreme conditions under which SiC is typically grown and the number of factors that can influence polytype selection. In situ monitoring of the synthesis process could significantly expand our ability to formulate novel polytype structures. In this perspective, we outline the state of the art and ongoing challenges for precision synthesis in SiC. We discuss available in situ x-ray characterization methods that will be instrumental in understanding the atomic scale growth of SiC and defect formation mechanisms. We highlight optimistic use cases for SiC heterostructures that will become possible with in situ polytypic control and end by discussing extended opportunities for integration of ultrahigh quality SiC materials with other semiconductor and quantum materials.
16 November 2020 in Physical Review Materials
Metal oxide/water interfaces play a crucial role in many electrochemical and photocatalytic processes, such as photoelectrochemical water splitting, the creation of fuel from sunlight, and electrochemical reduction. First-principles electronic structure calculations can reveal unique insights into these processes, such as the role of the alignment of the oxide electronic energy levels with those of liquid water. An essential prerequisite for the success of such calculations is the ability to predict accurate structural models of these interfaces, which in turn requires careful experimental validation. Here we report a general, quantitative validation protocol for first-principles molecular dynamics simulations of oxide/aqueous interfaces. The approach makes direct comparisons of interfacial x-ray reflectivity (XR) signals from experimental measurements and those obtained from ab initio simulations with semilocal and van der Waals functionals. The protocol is demonstrated here for the case of the /water interface, one of the simplest oxide/water interfaces. We discuss the technical requirements needed for validation, including the choice of the density functional, the simulation cell size, and the optimal choice of the thermodynamic ensemble. Our results establish a general paradigm for the validation of structural models and interactions at solid/water interfaces derived from first-principles simulations. While there is qualitative agreement between the simulated structures and the experimental best-fit structure, direct comparisons of simulated and measured XR intensities show quantitative discrepancies that derive from both bulk regions (i.e., alumina and water) as well as the interfacial region, highlighting the need for accurate density functionals to properly describe interfacial interactions. Our results show that XR data are sensitive not only to the atomic structure (i.e., the atom locations) but also to the electron-density distributions in both the substrate and at the interface.
24 March 2015 in Physics in Medicine & Biology
X-ray phase contrast imaging based on grating interferometers detects the refractive index distribution of an object without relying on radiation attenuation, thereby having the potential for reduced radiation absorption. These techniques belong to the broader category of optical wavefront measurement, which requires stepping the phase of the interference pattern to obtain a pixel-wise map of the phase distortion of the wavefront. While phase stepping traditionally involves mechanical scanning of a grating or mirror, we developed electromagnetic phase stepping (EPS) for imaging with compact sources to obviate the need for mechanical movement. In EPS a solenoid coil is placed outside the x-ray tube to shift its focal spot with a magnetic field, causing a relative movement between the projection of the sample and the interference pattern in the image. Here we present two embodiments of this method. We verified experimentally that electromagnetic and mechanical phase stepping give the same results and attain the same signal-to-noise ratios under the same radiation dose. We found that the relative changes of interference fringe visibility were within 3.0% when the x-ray focal spot was shifted by up to 1.0 mm in either direction. We conclude that when using x-ray tube sources, EPS is an effective means of phase stepping without the need for mechanical movement.