Taras Hanulia

Taras Hanulia

Auto-generated profile, based on publicly available information

Taras Hanulia

Department of Biomedical Engineering, Tufts University, Medford, MA, 02155, USA

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 July 2017 in Scientific Reports
Verified
Journal Article
Open access
PDF file
ITIchiro Tanabe
Ichiro Tanabe
YTYoshito Y. Tanaka
Yoshito Y. Tanaka
KWKoji Watari
Koji Watari
THTaras Hanulia
Taras Hanulia
TGTakeyoshi Goto
Takeyoshi Goto
YOYukihiro Ozaki
Yukihiro Ozaki
Surface plasmon resonance (SPR) sensors detect refractive index changes on metal thin films and are frequently used in aqueous solutions as bio- and chemical-sensors. Recently, we proposed new SPR sensors using aluminum (Al) thin films that work in the far- and deep-ultraviolet (FUV-DUV, 120–300 nm) regions and investigated SPR properties by an attenuated total reflectance (ATR) based spectrometer. The FUV-DUV-SPR sensors are expected to have three advantages compared to visible-SPR sensors: higher sensitivity, material selectivity, and surface specificity. However, in this study, it was revealed that the Al thin film on a quartz prism cannot be used as the FUV-DUV-SPR sensor in water solutions. This is because its SPR wavelength shifts to the visible region owing to the presence of water. On the other hand, the SPR wavelength of the Al thin film on the sapphire prism remained in the DUV region even in water. In addition, the SPR wavelength shifted to longer wavelengths with increasing refractive index on the Al thin film. These results mean that the Al thin film on the sapphire prism can be used as the FUV-DUV-SPR sensor in solutions, which may lead to the development of novel and sophisticated SPR sensors.

8 March 2024 in Lab on a Chip
Verified
Journal Article
Open access
PDF file
NVNilay Vora
Nilay Vora
PSPrashant Shekar
Prashant Shekar
THTaras Hanulia
Taras Hanulia
MEMichael Esmail
Michael Esmail
APAbani Patra
Abani Patra
IGIrene Georgakoudi
Irene Georgakoudi
We present a deep-learning enabled, label-free flow cytometry platform for identifying circulating tumor cell clusters in whole blood based on the endogenous scattering detected at three wavelengths. The method has potential for in vivo translation.

5 October 2017 in Chemistry Letters
Verified
Journal Article
Closed access
ITIchiro Tanabe
Ichiro Tanabe
YTYoshito Y. Tanaka
Yoshito Y. Tanaka
KWKoji Watari
Koji Watari
THTaras Hanulia
Taras Hanulia
TGTakeyoshi Goto
Takeyoshi Goto
YOYukihiro Ozaki
Yukihiro Ozaki
Aluminum film thickness dependence of surface plasmon resonance (SPR) in the far- and deep-ultraviolet regions (170–300 nm) was revealed using an attenuated total reflectance spectrometer. In the far-ultraviolet region (<200 nm), films of thicknesses 23 and 9 nm showed strong SPR excitations in air and 1,1,1,3,3,3-hexafluoro-2-propanol, which were reproduced by simulations based on the Fresnel equations, respectively. Therefore, Al-SPR sensors are expected to work both in air and in liquids by controlling the film thickness.

1 November 2018 in Optics Communications
Verified
Journal Article
Closed access
THTaras Hanulia
Taras Hanulia
WIWataru Inami
Wataru Inami
AOAtsushi Ono
Atsushi Ono
YKYoshimasa Kawata
Yoshimasa Kawata

27 April 2020 in Applied Physics Letters
Verified
Journal Article
Open access
PDF file
WSW. Strek
W. Strek
MOM. Oleszko
M. Oleszko
PWP. Wiewiórski
P. Wiewiórski
RTRobert Tomala
Robert Tomala
THT. Hanulia
T. Hanulia
The coherence properties of broadband white light emitted by graphene foam after irradiation with intense light of laser diodes were investigated. The interference fringes assigned to spatial and temporal coherence were observed for graphene white-light emission excited by two different excitation wavelengths of 975 nm and 808 nm of laser diodes. Both light sources were spectrally filtered to a narrow bandwidth in order to exclude the effect of temporal coherence. It was found that the coherence degree of white light emission of graphene differs depending on the excitation wavelength; however, no excitation power effect on the coherence degree was observed. The origin of coherence of laser-induced white emission of graphene is the stimulated emission due to the inversion population.

1 February 2021 in AIP Advances
Verified
Journal Article
Open access
PDF file
THT. Hanulia
T. Hanulia
MOM. Oleszko
M. Oleszko
RTRobert Tomala
Robert Tomala
Wieslaw StrekWieslaw Strek
Wieslaw Strek
The coherence properties of white light emission of a tungsten incandescent lamp additionally excited with laser radiation are investigated. The degree of spatial coherence is determined from measurements of the contrast of interference fringe patterns obtained for a tungsten bulb as the light source. It is demonstrated that the degree of spatial coherence of an incandescent lamp is increased by additional excitation of the filament with focused laser radiation. Furthermore, the degree of spatial coherence can be adjusted by selecting the voltage applied to the filament. Such light sources can find applications in imaging techniques where precise control of spatial coherence of illumination is required.