23 February 2024 in BMC Oral Health
Background: The aim of this study is to evaluate the stress distributions of a primary molar tooth restored with a stainless steel crown (SSC) using resin and glass ionomer luting cements by Finite Element Analysis (FEA). Methods: Original DICOM data of a primary molar was used to create a 3D model. One model was prepared as a tooth model with SSC. A 30 μm cement layer was used in model. Two different luting cements were tested in the study: self-cure adhesive resin cement, and glass ionomer cement. Vertical and oblique loads of 330 N were applied to simulate maximum bite force and lateral forces in the occlusal contact areas of the models. Maximum von Mises stress values in the models were evaluated as MPa. Results: The maximum von Mises stress value was observed in the force application and general occlusal contact areas for all models. The maximum von Mises stress values were higher in the tooth model with SSC using self-cure adhesive resin cement (478.09 MPa and 214.62 MPa) than in the tooth model with SSC using glass ionomer cement (220.06 MPa and 198.72 MPa) in both vertical and oblique loading, respectively. Conclusions: Depending on the magnitude of the bite force on the SSC, fracture of the luting cement materials could occur if the stress exceeds the endurance limit of the luting cement. Cementation with glass ionomer cement may help to reduce stress levels in SSC restorations of primary molars in children.
22 May 2023 in Computer Methods in Biomechanics and Biomedical Engineering
The aim of this study is to evaluate the stress distributions of low and high viscosity bulk-fill composite resins at class II MOD inlay cavity in primary molar tooth using Finite Element Analysis (FEA). Original DICOM data of a primary molar tooth from a research archive was used to create a 3D model. Two models were prepared as Model 1: the tooth model without restoration (control group) and Model 2: the tooth model with class II MOD inlay restoration. Two different bulk-fill composite resins were tested in study: Model 2 A (class II MOD inlay cavity model restored with low viscosity bulk-fill composite resin) and Model 2B (class II MOD inlay cavity model restored with high viscosity bulk-fill composite resin). Occlusal vertical loading of 232 N was applied to the teeth in occlusal contact areas. Maximum Von Mises stress values in the models for enamel, dentin, and restorative material were evaluated as MPa. More intense stress accumulation is observed in enamel than in dentin. In addition, more stress values were determined in Model 2B (206.15 MPa, 32.76 MPa, 128.95 MPa) than in Model 2 A (203.39 MPa, 29.77 MPa, 120.61 MPa) for enamel, dentin and restorative material, respectively.
15 December 2019 in Karadeniz Fen Bilimleri Dergisi
CoCrMo alaşımı, yüksek darbe ve yorulma dayanımı gibi özellikleri sayesinde ortopedik implant malzemesi olarak yaygın kullanılmaktadır. Bu alaşım yüksek korozyon dayanımı göstermesine rağmen düşük aşınma dayanımına sahiptir. Yapay eklem implant malzemesi olarak kullanıldığında, korozif vücut sıvısı nedeniyle düşük sürtünme özelliği ve düşük korozyon direnci göstermekte olup kısa sürelerde aşınmalara maruz kalmaktadırlar. Bu nedenle, CoCrMo alaşım yüzeyine korozyonu ve aşınma direncini geliştirmek için yüzey kaplama işlemi yapılmaktadır. Bu çalışmada CoCrMo alaşımının yüzeyinin tribolojik özelliklerini geliştirmek için kapalı alanda dengesiz magnetron püskürtme işlemi ile çok katmanlı kaplanmıştır. Kaplama mimarisi Cr/CrN/CrCN/TaN dizilimine sahip olup tabaka sayısı iki, dört ve sekizdir. Kaplamaların tribolojik özelliklerini karakterize etmek için disk üzerinde pin aşınma testi, sertlik ve yüzey pürüzlülüğü ölçümleri yapılmıştır. Sonuçlar, alaşımın tribolojik özelliklerinin önemli ölçüde arttığını göstermiştir. Tabaka sayısının artması ile örneklerin aşınma dayanımı, sertliği ve yüzey kalitesinin arttığı gözlenmiştir.
1 January 2022 in Open Chemistry
The aim of this finite element analysis study is to evaluate the stress distributions of different types of restorative materials at Class I cavity in the primary molar. The non-cracked caries-free primary mandibular second molar that is extracted for orthodontic reasons is used to create a three-dimensional model. Two models were prepared as Model 1: the tooth model without restoration (control group) and Model 2: the tooth model with Class I restoration. Five different types of restorative materials were tested in Model 2 (resin modified glass ionomer [Fuji II LC], compomer [Dyract AP], giomer [Beautiful II], glass carbomer [GPC Glass Fill] and ionic resin material with bioactive properties [Activa Kids Bioactive]). A force of 197 N was applied in the vertical and oblique directions in the ANSYS program (Ansys Workbench 19.0, Canonsburg, PA). The maximum Von Mises stress values were compared in the models. The vertical or oblique loading created different stresses in enamel, dentin and restorative materials. The stresses in the enamel tissue were higher than that in the dentin tissue. The stresses in vertical loading were higher than in the oblique loading for restorative materials. The different restorative materials exhibited similar stress distribution patterns, except Activa Kids Bioactive (vertical and oblique loading 446.16 and 8.57, respectively).
31 December 2021 in Selcuk Dental Journal
Background: The purpose of the present study was to evaluate the stress distributions of zirconia or titanium connecting screws under different loads (vertical and oblique) in bruxism patients and to indicate its applicability by comparing with physiological stress limit values.. Methods: Four different models were created in which the implants were the same size and design, with dental implant, abutment and connection screws made of zirconia or Ti (only screw). 3D-Finite element analysis (3D-FEA) was applied to study the effect of a vertical load (1000 N) and oblique load (an angle of 30°) on abutments in the models. The placement of implants are mandibular right first molar. Computerized tomography imaging of cadaver mandibles was used. Von Mises stresses of the different screw materials were compared with each other and the physiological stress limit values for zirconia. Results: Von Mises stress values increased in oblique loading in all models. The von Mises stress values were significantly reduced in the titanium screw than zirconium under both loading simulations. Conclusion: In patients with a high biting force physiological stress limit values for zirconia were not exceeded. Zircon connection screw may be used in patients with bruxism.
26 December 2019 in Bilecik Şeyh Edebali Üniversitesi Fen Bilimleri Dergisi
Kalça protez kullanımı artan ortalama yaşam süresine ve nüfusa bağlı olarak gün geçtikçe artmaktadır. Üstün klinik başarıya rağmen aşınmaya bağlı olarak kalça protezlerinin gevşemesi ve ağrılı süreçlerin tekrar başlaması beklenen bir durum haline gelmiştir. Bunların engellenebilmesi için yapılan çalışmalar in vitro ortamlarda test edilerek sağlık alanında gelişmeler kaydetmektdir. Bu makalede de kalça protezlerinde ki in vitro test koşullarını daha kısa sürelerde sağlamak amacıyla kas-iskelet simülasyon tanımlanan Sonlu Elemanlar Yöntemi ile analizler gerçekleştirildi. Bunun için erişkin hastaya ait femur kemiği, bu kemiğe uygun kalça protezi ve 172 adet kas birim yük değeri kullanıldı. Yapılan analizler sonucunda kas sistemlerinin aşınma derinliğini ve gerilmeleri azalttığı belirlendi.