23 September 2024 in International Journal of Emerging Electric Power Systems
Microgrids are a growing segment of the energy industry, representing a paradigm shift from remote central station power plants toward more localized, distributed generation. An efficient energy management structure is essential for a DC Microgrid with a PV system combined with a Hybrid Energy Storage System (HESS) of Battery and Supercapacitor. The combined supercapacitor and battery storage system provides a quick control for the DC-link voltage. It stabilizes the system and helps achieve smooth PV power delivery to loads. The boost converter used for the PV system is controlled by a Maximum Power Point Tracking (MPPT) method to extract maximum power and maintain a constant voltage at the DC bus despite the daily change in solar power. The boost-buck converter is used to control the charging and discharging processes of the BESS to maintain a constant voltage at the DC bus. To achieve the seamless operation of DC Microgrid with HESS during the power fluctuations, this work proposes power coordination and control scheme has been proposed. To analyse the performance and efficacy of the proposed DC Microgrid with HESS are implemented in MATLAB/SIMULINK.
6 June 2023 in Energy Systems
20 May 2025 in Engineering Research Express
In this paper, a three-phase T-type Three Level (TTL) inverter with Distributed Static Compensator (DSTATCOM) using Anti-Hebbian based Least Mean Square (AHLMS) control approach is proposed to alleviate the power quality issues. The design and modeling of a controller for the DSTATCOM device is constrained by the evaluation of shunt compensation and associated power quality issues. In this work, the AHLMS control approach is presented to control the DSTATCOM and its performance is evaluated under various loading conditions. The AHLMS is an upgraded variant of the Hebbian Least Mean Square (HLMS) control approach that employs an appropriate pattern of learning mechanism. Each controller is constructed as an individual neural network structure based on the system’s flexibility and experimental use. In order to produce reference source currents, the control approach seeks to isolate necessary active and reactive components from load currents. The AHLMS control approach outperforms in terms of voltage balancing, enhancing power factor correction, harmonic reduction, and voltage regulation of TTL inverter when there are disturbances triggered by even and uneven loading situations. The simulation model for the three-phase TTL inverter based DSTATCOM configuration is verified by MATLAB/Simulink. The performance of three-phase TTL inverter based DSTATCOM using AHLMS approach is analyzed under both uniformity and diversity loading conditions. Furthermore, the TTL inverter results are contrasted with that of the 2-level inverter with respect to DC link voltage, oscillations, and current harmonics at both the source and load sides. The TTL inverter DC link capacitor oscillates from 530 to 532 V with minimal oscillations compared to 2-level inverters under even loading. Overall, by using AHLMS control approach, the %THD of TTL inverter is obtained as 3.28%, which is less than the allowed %THD of 5%.
1 January 2026 in Engineering Research Express
This work presents a dual-output Boost–SEPIC converter developed for compact and efficient auxiliary power management in electric vehicles. The converter independently regulates two output voltages that may be higher, lower, or equal to the input, while its hybrid topology reduces component count and enhances power density. The study includes steady-state analysis, small-signal modelling, and derivation of key transfer functions to support controller design. A digital current-programmed predictive control strategy is implemented to achieve accurate current tracking, low ripple, and reliable response under dynamic load conditions. Simulation and experimental results validate the robustness of the proposed system, demonstrating stable dual-output regulation, improved efficiency, and reduced stress on the energy storage unit. These contributions collectively highlight the converter’s novelty as a compact and intelligent power solution for next-generation electric mobility platforms.
11 May 2026 in Engineering Research Express
DC microgrids integrating renewable energy sources such as solar and wind require robust control strategies to ensure stable voltage regulation under varying operating conditions. This paper proposes an Adaptive Fuzzy PID (AFPID) controller for voltage regulation in a solar-based DC microgrid and compares its performance with a conventional Fuzzy PID (FPID) controller. The proposed control strategy is implemented in the DC–DC converter interfaced with a photovoltaic (PV) system operating under maximum power point tracking (MPPT). The effectiveness of the AFPID controller is evaluated based on key dynamic performance indices including settling time, steady-state error, overshoot, and oscillation magnitude. Simulation results obtained using MATLAB/Simulink demonstrate that the AFPID controller significantly improves system performance. Specifically, the settling time is reduced from 3.0 s (FPID) to 1.5 s (AFPID), representing a 50% improvement. The steady-state error decreases from 0.015 to 0.008, while the overshoot is reduced from 4.5% to 1.8%. These results confirm enhanced transient response and improved voltage stability.
21 April 2026 in Engineering Research Express
The growing use of solar photovoltaic systems needs dependable multiport DC-DC converters that can perform at high levels. The performance of converters declines when semiconductor components experience open-circuit or short-circuit faults because these faults require immediate detection to prevent total system failure. A unified system for current control and fault detection based on diode current as a shared state element for output control and fault detection has been developed in this research paper for solar-powered multiport DC-DC converters. The predictive control law establishes duty cycle estimation through charge-second balance principles, which allow voltage regulation to function properly during standard operations without needing extra sensor equipment. The analysis through frequency-domain methods shows the closed-loop system maintains stable operation because it runs with a 1.318 kHz bandwidth and positive phase margin, which allows for quick system response and protection against disturbances. The diagnostic algorithm proposed in this study measures diode current during multiple switching periods to investigate conduction properties, which help identify normal functioning versus OC and SC faults. The experimental tests on a laboratory prototype running at 20 kHz show that the system can detect faults within a time period shorter than one-fourth of the switching cycle, which enables quick fault management and improved system security. The proposed method achieves multiple benefits by lowering both sensor requirements and system processing demands while providing quick fault detection, accurate fault identification, and consistent output control for renewable energy systems and critical power electronic systems. The effectiveness of the proposed method is validated through both simulation and experiment using a 200 W laboratory prototype, where accurate fault detection and control performance are achieved.