12 June 2022 in Magnetic Resonance in Medicine
Purpose: Cardiac MRI represents the gold standard to determine myocardial function. However, the current clinical standard protocol, a segmented Cartesian acquisition, is time‐consuming and can lead to compromised image quality in the case of arrhythmia or dyspnea. In this article, a machine learning–based reconstruction of undersampled spiral k‐space data is presented to enable free breathing real‐time cardiac MRI with good image quality and short reconstruction times.Methods: Data were acquired in free breathing with a 2D spiral trajectory corrected by the gradient system transfer function. Undersampled data were reconstructed by a variational network (VN), which was specifically adapted to the non‐Cartesian sampling pattern. The network was trained with data from 11 subjects. Subsequently, the imaging technique was validated in 14 subjects by quantifying the difference to a segmented reference acquisition, an expert reader study, and by comparing derived volumes and functional parameters with values obtained using the current clinical gold standard.Results: The scan time for the entire heart was below 1 min. The VN reconstructed data in about 0.9 s per image, which is considerably shorter than conventional model‐based approaches. The VN furthermore performed better than a U‐Net and not inferior to a low‐rank plus sparse model in terms of achieved image quality. Functional parameters agreed, on average, with reference data.Conclusions: The proposed VN method enables real‐time cardiac imaging with both high spatial and temporal resolution in free breathing and with short reconstruction time.
3 December 2020 in Magnetic Resonance in Medicine
Purpose Segmented Cartesian acquisition in breath hold represents the current gold standard for cardiac functional MRI. However, it is also associated with long imaging times and severe restrictions in arrhythmic or dyspneic patients. Therefore, we introduce a real‐time imaging technique based on a spoiled gradient‐echo sequence with undersampled spiral k‐space trajectories corrected by a gradient pre‐emphasis. Methods A fully automatic gradient waveform pre‐emphasis based on the gradient system transfer function was implemented to compensate for gradient inaccuracies, to optimize fast double‐oblique spiral MRI. The framework was tested in a phantom study and subsequently transferred to compressed sensing–accelerated cardiac functional MRI in real time. Spiral acquisitions during breath hold and free breathing were compared with this reference method for healthy subjects (N = 7) as well as patients (N = 2) diagnosed with heart failure and arrhythmia. Left‐ventricular volumes and ejection fractions were determined and analyzed using a Wilcoxon signed‐rank test. Results The pre‐emphasis successfully reduced typical artifacts caused by k‐space misregistrations. Dynamic cardiac imaging was possible in real time (temporal resolution < 50 ms) with high spatial resolution (1.34 × 1.34 mm2), resulting in a total scan time of less than 50 seconds for whole heart coverage. Comparable image quality, as well as similar left‐ventricular volumes and ejection fractions, were observed for the accelerated and the reference method. Conclusion The proposed technique enables high‐resolution real‐time cardiac MRI with no need for breath holds and electrocardiogram gating, shortening the duration of an entire functional cardiac exam to less than 1 minute.
30 March 2022 in NMR in Biomedicine
The purpose of the current study was to implement and validate joint real‐time acquisition of functional and late gadolinium‐enhancement (LGE) cardiac magnetic resonance (MR) images during free breathing. Inversion recovery cardiac real‐time images with a temporal resolution of 50 ms were acquired using a spiral trajectory (IR‐CRISPI) with a pre‐emphasis based on the gradient system transfer function during free breathing. Functional and LGE cardiac MR images were reconstructed using a low‐rank plus sparse model. Late gadolinium‐enhancement appearance, image quality, and functional parameters of IR‐CRISPI were compared with clinical standard balanced steady‐state free precession breath‐hold techniques in 10 patients. The acquisition of IR‐CRISPI in free breathing of the entire left ventricle took 97 s on average. Bland–Altman analysis and Wilcoxon tests showed a higher artifact level for the breath‐hold technique (p = 0.003), especially for arrhythmic patients or patients with dyspnea, but an increased noise level for IR‐CRISPI of the LGE images (p = 0.01). The estimated transmural extent of the enhancement differed by not more than 25% and did not show a significant bias between the techniques (p = 0.50). The ascertained functional parameters were similar for the breath‐hold technique and IR‐CRISPI, that is, with a minor, nonsignificant (p = 0.16) mean difference of the ejection fraction of 2.3% and a 95% confidence interval from −4.8% to 9.4%. IR‐CRISPI enables joint functional and LGE imaging in free breathing with good image quality but distinctly shorter scan times in comparison with breath‐hold techniques.