1 August 2017 in Toxicology in Vitro
The Vitrocell® 24/48 is an advanced aerosol exposure system that has been widely used and characterized for exposure studies of cigarette smoke, but not for exposure to liquid aerosols with a low gas-vapor phase content such as the ones generated by electronic cigarettes. An experimental system characterization for this specific application was therefore performed. Glycerol model aerosols of different particle size distributions, produced by a condensation monodisperse aerosol generator, were used for exposing small volumes of phosphate-buffered saline in the Vitrocell® 24/48. Disodium fluorescein, added as a tracer in the aerosol, allowed the exact aerosol mass deposition to be quantified fluorometrically. The aerosol mass delivery efficiency within the system showed variations in the range of ±25%. Aerosol dilution was not fully reflected in aerosol delivery, the achieved aerosol delivery should therefore be determined experimentally. Quartz crystal microbalances underestimated the deposition of liquid aerosols. Unequal delivery of particles of different sizes was detectable, although this effect is unlikely to be relevant under applied experimental conditions. The Vitrocell® 24/48 aerosol exposure system can be used for exposures to liquid aerosols, such as those generated by electronic cigarettes. However, our results indicate that, compared with aerosol studies of cigarettes, a higher variability is to be expected.
1 June 2014 in Analytical and Bioanalytical Chemistry
1 February 2017 in Toxicology in Vitro
Knowledge of how an in vitro aerosol exposure system delivers a test aerosols to the biological test system is among the most crucial prerequisites for the interpretation of exposure experiments and relies on detailed exposure system characterization. Although various methods for this purpose exist, many of them are time consuming, require extensive instrumentation, or offer only limited ability to assess the performance of the system under experimental settings. We present the development and evaluation of a new, highly robust and sensitive fluorometry-based method for assessing the particle size specific delivery of liquid aerosols. Glycerol aerosols of different mean particle sizes and narrow size distributions, carrying the fluorophore disodium fluorescein, were generated in a condensation monodisperse aerosol generator. Their detailed characterization confirmed their stability and the robustness and reproducibility of their generation. Test exposures under relevant experimental settings in the Vitrocell® 24/48 aerosol exposure system further confirmed their feasibility for simulating exposures and the high sensitivity of the method. Potential applications of the presented method range from the experimental confirmation of computationally simulated particle dynamics, over the characterization of in vitro aerosol exposure systems, to the detailed description of aerosol delivery in test systems of high complexity.
9 July 2018 in Toxicology in Vitro
In vitro aerosol exposure of epithelial cells grown at the air-liquid interface is an experimental methodology widely used in respiratory toxicology. The exposure depends to a large part on the physicochemical properties of individual aerosol constituents, as they determine the transfer kinetics from the aerosol into the cells. We characterized the transfer of 70 cigarette smoke constituents from the smoke into aqueous samples exposed in the Vitrocell® 24/48 aerosol exposure system. The amounts of these compounds in the applied smoke were determined by trapping whole smoke in N,N-Dimethylformamide and then compared with their amounts in smoke-exposed, phosphate-buffered saline, yielding compound specific delivery efficiencies. Delivery efficiencies of different smoke constituents differed by up to five orders of magnitude, which indicates that the composition of the applied smoke is not necessarily representative for the delivered smoke. Therefore, dose metrics for in vitro exposure experiments should, if possible, be based on delivered and not applied doses. A comparison to literature on in vivo smoke retention in the respiratory tract indicated that the same applies for smoke retention in the respiratory tract.
1 September 2020 in Toxicology in Vitro
The dose of inhaled materials delivered to the respiratory tract is to a large extent a function of the kinetics of particle deposition and gas dissolution on or in the airway and lung epithelia, and therefore of the structural and functional properties of the respiratory tract. In vitro aerosol exposure systems commonly do not simulate these properties, which may result in the delivery of non-realistic, non-human-relevant doses of inhalable test substances to the in vitro biological test systems. We developed a new-generation in vitro aerosol exposure system, the InHALES, that can, like the human respiratory tract, actively breathe, operate medical inhalers, or take puffs from tobacco products. Due to its structural and functional similarity to the human respiratory tract, the system is expected to deliver human-relevant doses of inhalable materials to cell cultures representing respiratory tract epithelia. We here describe the proof of concept of the InHALES with respect to aerosol delivery and compatibility with oral, bronchial, and alveolar cell cultures. The results indicate that the system structure and function translate into complex patterns of test atmosphere delivery that, with increasing system complexity, may closely mimic the patterns observable in the human respiratory tract.
30 June 2023 in Archives of Microbiology
In the COVID-19 pandemic, caused by the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), face masks have become a very important safety measure against the main route of transmission of the virus: droplets and aerosols. Concerns that masks contaminated with SARS-CoV-2 infectious particles could be a risk for self-contamination have emerged early in the pandemic as well as solutions to mitigate this risk. The coating of masks with sodium chloride, an antiviral and non-hazardous to health chemical, could be an option for reusable masks. To assess the antiviral properties of salt coatings deposited onto common fabrics by spraying and dipping, the present study established an in vitro bioassay using three-dimensional airway epithelial cell cultures and SARS-CoV-2 virus. Virus particles were given directly on salt-coated material, collected, and added to the cell cultures. Infectious virus particles were measured by plaque forming unit assay and in parallel viral genome copies were quantified over time. Relative to noncoated material, the sodium chloride coating significantly reduced virus replication, confirming the effectiveness of the method to prevent fomite contamination with SARS-CoV-2. In addition, the lung epithelia bioassay proved to be suitable for future evaluation of novel antiviral coatings.