Geoffrey William Schemitsch

Geoffrey William Schemitsch

Auto-generated profile, based on publicly available information

Geoffrey William Schemitsch

Division of Orthopaedic Surgery, Department of Surgery, University of Toronto, Toronto, Ontario, Canada

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 June 2023 in OTA International
Verified
Journal Article
Open access
HMHiroaki Minehara
Hiroaki Minehara
AMAkihiro Maruo
Akihiro Maruo
RARafael Amadei
Rafael Amadei
ACAchille Contini
Achille Contini
ABAdriano Braile
Adriano Braile
TMTheodore Iii Miclau
Theodore Iii Miclau
Summary: Severe open fractures present challenges to orthopaedic surgeons worldwide, with increased risks of significant complications. Although different global regions have different resources and systems, there continue to be many consistent approaches to open fracture care. Management of these complex injures continues to evolve in areas ranging from timing of initial operative debridement to the management of critical-sized bone defects. This review, compiled by representative members of the International Orthopaedic Trauma Association, focuses on several critical areas of open fracture management, including antibiotic administration, timing of debridement, bone loss, soft tissue management, and areas of need for future investigation.

1 August 2025 in JBJS Reviews
Verified
Journal Article
Closed access
GSGeoffrey W. Schemitsch
Geoffrey W. Schemitsch
DLDarius L. Lameire
Darius L. Lameire
GHGraeme Hoit
Graeme Hoit
MVManav Vyas
Manav Vyas
AKAmir Khoshbin
Amir Khoshbin
NANeill Adhikari
Neill Adhikari
Background: Operative management of acetabular fractures can be complicated by the development of symptomatic post-traumatic arthritis, which may necessitate conversion total hip arthroplasty (THA). There is increased interest in treatment with THA for acute management, but optimal patient selection depends on identifying those at risk of later symptomatic post-traumatic arthritis requiring conversion THA. Methods: We systematically reviewed prognostic factors associated with conversion THA in adult patients with operatively managed acetabulum fractures. We searched MEDLINE and EMBASE from inception to September 27, 2024. Screening, data extraction, risk of bias assessment, and evidence grading were completed in duplicate. Data were pooled using a random-effects model to produce summary odds ratios (ORs), hazard ratios (HRs), and mean differences, with 95% confidence intervals (CIs). Risk of bias was assessed using the Quality in Prognosis Studies tool. Certainty of evidence was evaluated using the Grade of Recommendation, Assessment, Development, and Evaluation framework. Results: A total of 3,054 citations were screened, and 38 studies (6,931 fractures) met inclusion criteria. Eight factors were associated with conversion THA in unadjusted analyses: acetabular impaction (OR 2.08, 95% CI 1.60-2.70, moderate certainty), femoral head impaction (OR 2.70, 95% CI 1.80-4.06, moderate certainty), dislocation (OR 2.20, 95% CI 1.51-3.19, moderate certainty), nonanatomic reduction on radiography (OR 2.36, 95% CI 1.58-3.51, moderate certainty), nonanatomic reduction on computed tomography (OR 3.46, 95% CI 1.25-9.57, moderate certainty), associated fracture type (OR 1.76, 95% CI 1.29-2.41, moderate certainty), female sex (OR 1.48, 95% CI 1.15-1.88, moderate certainty), and posterior wall involvement (OR 1.82, 95% CI 1.18-2.80, moderate certainty). In multivariable analyses, age (adjusted OR 1.04, 95% CI 1.02-1.06, high certainty; adjusted HR 1.04, 95% CI 1.03-1.05, high certainty) and femoral head impaction (adjusted HR 3.19, 95% CI 1.16-8.75, moderate certainty) were associated with conversion THA. The weighted proportion of patients requiring THA conversion was 17.6% (95% CI 15.2%-20.4%, low certainty). Conclusion: Older age and femoral head impaction were the only factors associated with conversion to THA in univariable and multivariable analyses. Level of Evidence: Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.

4 January 2024 in Orthopaedic Journal of Sports Medicine
Verified
Journal Article
Open access
GSGeoffrey W. Schemitsch
Geoffrey W. Schemitsch
THTyler M. Hauer
Tyler M. Hauer
GHGraeme Hoit
Graeme Hoit
FHFahad H. Al Hulaibi
Fahad H. Al Hulaibi
SHShu Yang Hu
Shu Yang Hu
DWDaniel B. Whelan
Daniel B. Whelan
Background: Varus and valgus knee stress radiographs provide valuable information in the pre- and postoperative evaluation of joint laxity in patients with multiligament knee injuries (MLKIs). Purpose: To review the literature for described techniques of quantifying laxity on coronal stress radiographs of the knee and identify the most reliable method. Study Design: Cohort study (diagnosis); Level of evidence, 3. Methods: A thorough literature search using the MEDLINE and Embase databases identified 4 studies with distinct methods for objectively measuring laxity on varus and valgus stress radiographs: Heesterbeek et al (2008), Jacobsen (1976), LaPrade et al (2004), and Sawant et al (2004). To compare these methods, 200 coronal plane stress radiographs from 50 patients with MLKIs were retrospectively reviewed from an MLKI database at a single institution. The amount of varus and valgus laxity on each radiograph was measured independently by 4 reviewers using each method. Intraclass correlation coefficients (ICCs) with 95% CIs were calculated to assess the interobserver reliability of each method overall and the varus and valgus measurements individually. Results: For all 4 methods, the overall interobserver reliability was considered at least moderate. The method by Heesterbeek et al proved to have the highest interrater reliability in all domains—overall (ICC, 0.87 [95% CI, 0.85-0.90]), valgus (ICC, 0.83 [95% CI, 0.78-0.88]), and varus (ICC, 0.87 [95% CI, 0.83-0.90])—demonstrating good to excellent reliability both overall and in varus measurements and showing good reliability in valgus measurements. The method by Sawant et al demonstrated good reliability in valgus measurements. All other measures demonstrated moderate reliability. Conclusion: Available methods for measuring knee joint laxity on varus and valgus knee stress radiographs in patients with MLKIs demonstrated moderate to good interobserver reliability. The method described by Heesterbeek et al proved to have the highest reliability overall as well as in measurements on varus and valgus views individually.

1 August 2025 in OTA International
Verified
Journal Article
Open access
NLNithya Lingampalli
Nithya Lingampalli
GSGeoffrey W. Schemitsch
Geoffrey W. Schemitsch
WOWilliam Obremskey
William Obremskey
ESEmil H. Schemitsch
Emil H. Schemitsch
ALAshley E. Levack
Ashley E. Levack
In North America, orthopaedic trauma and fracture registries can be broadly categorized into 4 groups: national registries without subscription, national registries with subscription, for-profit registries, and nontrauma-specific and insurance databases. In the United States, the National Trauma Data Bank is the largest national trauma registry and can be freely accessed but lacks many specifics and outcomes pertinent to patients with fracture as data are only for the inpatient stay. The Orthopaedic Trauma Association/American Academy of Orthopaedic Surgeons Fracture and Trauma Registry is a 2-year-old subscription-based database designed to account for shortcomings in the now defunct Orthopaedic Trauma Association fracture registry. Three additional registries exist with focused patient populations: Own the Bone (a subscription-based database focused on osteoporotic fractures and secondary prevention) and 2 military registries, the Department of Defense Trauma Registry and Military Orthopedic Trauma Registry (both restricted-access databases focusing on combat-related fractures and injuries sustained by military personnel). In Canada, there is no active national trauma registry. The previous National Trauma Registry was operational from 1997 to 2014, but closed because of limited use, reallocation of funding, and lack of data timeliness. Provincial trauma registries are the source of most trauma-specific registry data; however, most fragility fractures and other low-energy injuries are not captured. North America's most widely used registries, the National Trauma Data Bank and Canadian provincial registries, provide little data on fracture-specific outcomes. The addition of fracture-specific variables and outcomes would significantly enhance the ability for these registries to become a more valuable resource for orthopaedic surgeons.

27 May 2025 in Shoulder & Elbow
Verified
Journal Article
Open access
GSGeoffrey W Schemitsch
Geoffrey W Schemitsch
PCPatrick Carroll
Patrick Carroll
PHPatrick Henry
Patrick Henry
DNDiane Nam
Diane Nam
USUjash Sheth
Ujash Sheth
Background: Pyrocarbon has been trialed as an alternative bearing surface to metal for young active patients with glenohumeral joint arthritis. The aim of this study was to systematically review and summarize the available evidence on reported outcomes of pyrocarbon implants in shoulder arthroplasty. Methods: A systematic review was conducted according and reported according to standardized guidelines. Patient demographics, complications, implant survivorship and patient-reported outcome measures were extracted and included in the quantitative analysis. Outcome data was summarized with weighted mean differences and proportions. Results: Fifteen studies were included with 904 patients and a median follow-up of 38 months. The pooled mean range of motion improvement was 43.9 degrees (95% confidence interval [95% CI] 36.7–51.2) in forward elevation and 24.1 degrees (95% CI 18.4–29.9) in external rotation. Pooled mean Constant Score improvement was 34.7 (95% CI 29.4–40.1) and Subjective Shoulder Value improvement was 40.6 (95% CI 33.4–47.8). The overall pooled re-operation rate was 8.03% (95% CI 5%–12.7%). Discussion: Pyrocarbon shoulder implants demonstrated improvements in functional outcomes with low revision rates at early- to mid-term follow-up. Further well-designed prospective studies with long-term follow-up are required to verify the safety and efficacy of pyrocarbon implants in shoulder arthroplasty.

25 April 2026 in Mayo Clinic Proceedings: Digital Health
Verified
Journal Article
Open access
KWKevin J. Wang
Kevin J. Wang
AAAazad Abbas
Aazad Abbas
GSGeoffrey W. Schemitsch
Geoffrey W. Schemitsch
MRMatthew Raleigh
Matthew Raleigh
JLJohnathan R. Lex
Johnathan R. Lex
RKRobert Koucheki
Robert Koucheki
To synthesize the performance of artificial intelligence (AI) applications for detecting pelvic fractures, classifying severity, and predicting clinical outcomes relative to clinicians. The study was designed as a systematic review and meta-analysis (PROSPERO CRD420251141768). Ovid Embase, Ovid MEDLINE, PubMed, Scopus, and Cochrane CENTRAL were searched for articles published from database inception to September 11, 2025. Studies were included if they evaluated AI models for pelvic ring fractures in adults using pelvic radiographs. Case series, reviews, and abstracts without full data were excluded. Summary level data were independently extracted using a standardized template. Diagnostic metrics were pooled using a random-effects model. Outcomes included pooled sensitivity, specificity, area under the receiver operating characteristic curve (AUC), and accuracy. Fourteen studies were included. Thirteen studies evaluated radiographic fracture detection or classification (n=31,166 radiographs) and one study evaluated outcome prediction. AI demonstrated high pooled performance: accuracy 0.96 (95% CI, 0.91-0.98; I2=93.3%), AUC 0.94 (95% CI, 0.89-0.97; I2=97.9%), sensitivity 0.90 (95% CI, 0.84-0.94; τ2=0.42), and specificity 0.93 (95% CI, 0.85-0.97; τ2=1.30). In 3 studies directly comparing AI with clinicians, AI models showed comparable or marginally superior performance. One study on clinical outcomes reported strong performance for predicting hemodynamic instability (AUC 0.92) and mortality (AUC 0.90). AI algorithms show promise as supportive tools for pelvic fracture detection, achieving diagnostic performance comparable to expert clinicians. However, included studies exhibit substantial heterogeneity, selection bias, and limited external validation. Large-scale, prospective validation is necessary before widespread clinical adoption.