1 May 2023 in Magnetic Resonance in Medicine
ETElizabeth M. Tunnicliffe
Purpose: The spoiled gradient recalled echo (SPGR) sequence with variable flip angles (FAs) enables whole liver mapping at high spatial resolutions but is strongly affected by inhomogeneities. The aim of this work was to study how the precision of acquired maps is affected by the and ranges observed in the liver at 3T, as well as how noise propagates from the acquired signals into the resulting map.Theory: The variance was estimated through the Fisher information matrix with a total noise variance including, for the first time, the map noise as well as contributions from the SPGR noise.Methods: Simulations were used to find the optimal FAs for both the mapping and mapping. The simulations results were validated in 10 volunteers.Results: Four optimized SPGR FAs of 2°, 2°, 15°, and 15° (TR = 4.1 ms) and map FAs of 65° and 130° achieved a coefficient of variation of 6.2 ± 1.7% across 10 volunteers and validated our theoretical model. Four optimal FAs outperformed five uniformly spaced FAs, saving the patient one breath‐hold. For the liver and parameter space at 3T, a higher return in precision was obtained by investing FAs in the SPGR acquisition rather than in the map.Conclusion: A novel framework was developed and validated to calculate the SPGR variance. This framework efficiently identifies optimal FA values and determines the total number of SPGR and measurements needed to achieve a desired precision.
4 February 2025 in Magnetic Resonance in Medicine
ETElizabeth M. Tunnicliffe
Purpose: To develop an accurate and precise liver 3D mapping method using only scanner‐agnostic sequences. Methods: While the spoiled gradient‐recalled echo sequence is widely available on clinical scanners, variable flip angle mapping methods based on this sequence provide biased estimates, with the largest systematic error arising from inhomogeneities. To correct for this, the flip angle was mapped using a 2D gradient‐echo double‐angle method approach. To correct for the confounding effect of fat on liver and , Dixon and fat saturation techniques were used in combination with the variable flip angle and the map acquisitions, respectively. The and mapping methods were validated with a ‐phantom against gold standard methods. An intra‐ and inter‐repeatability study was conducted at 3T in 10 healthy individuals' livers. Results: The developed 3D mapping method achieved an excellent agreement with the gold standard, with a weighted root mean squared normalized error below 2.8%. In vivo, a median standard deviation of 31 ms and an interquartile range of [27, 39] ms was achieved across all measurements, including the intra‐ and inter‐repeatability study data. A within‐subject standard deviation for of 21 ± 5 ms had a corresponding repeatability coefficient of 60 ms. The measured values agree well with MOLLI and SASHA mapping methods, with average differences of 5%. Conclusion: Accurate and precise 3D liver measurements can lead the way to the wider adoption of a clinically feasible measurement as a marker of hepatic fibro‐inflammation.
19 January 2022 in Physics in Medicine & Biology
Breathing motion can displace internal organs by up to several cm; as such, it is a primary factor limiting image quality in medical imaging. Motion can also complicate matters when trying to fuse images from different modalities, acquired at different locations and/or on different days. Currently available devices for monitoring breathing motion often do so indirectly, by detecting changes in the outline of the torso rather than the internal motion itself, and these devices are often fixed to floors, ceilings or walls, and thus cannot accompany patients from one location to another. We have developed small ultrasound-based sensors, referred to as ‘organ configuration motion’ (OCM) sensors, that attach to the skin and provide rich motion-sensitive information. In the present work we tested the ability of OCM sensors to enable respiratory gating during in vivo PET imaging. A motion phantom involving an FDG solution was assembled, and two cancer patients scheduled for a clinical PET/CT exam were recruited for this study. OCM signals were used to help reconstruct phantom and in vivo data into time series of motion-resolved images. As expected, the motion-resolved images captured the underlying motion. In Patient #1, a single large lesion proved to be mostly stationary through the breathing cycle. However, in Patient #2, several small lesions were mobile during breathing, and our proposed new approach captured their breathing-related displacements. In summary, a relatively inexpensive hardware solution was developed here for respiration monitoring. Because the proposed sensors attach to the skin, as opposed to walls or ceilings, they can accompany patients from one procedure to the next, potentially allowing data gathered in different places and at different times to be combined and compared in ways that account for breathing motion.
29 December 2023 in Magnetic Resonance in Medicine
Purpose: To show that variations through slice and slice profile effects are two major confounders affecting 2D dual angle maps using gradient‐echo signals and thus need to be corrected to obtain accurate maps.Methods: The 2D gradient‐echo transverse complex signal was Bloch‐simulated and integrated across the slice dimension including nonlinear variations in inhomogeneities through slice. A nonlinear least squares fit was used to find the factor corresponding to the best match between the two gradient‐echo signals experimental ratio and the Bloch‐simulated ratio. The correction was validated in phantom and in vivo at 3T.Results: For our RF excitation pulse, the error in the factor scales by approximately 3.8% for every 10 Hz/cm variation in along the slice direction. Higher accuracy phantom maps were obtained after applying the proposed correction; the root mean square error relative to the gold standard decreased from 6.4% to 2.6%. In vivo whole‐liver maps using the corrected map registered a significant decrease in gradient through slice.Conclusion: inhomogeneities varying through slice were seen to have an impact on the accuracy of 2D double angle maps using gradient‐echo sequences. Consideration of this confounder is crucial for research relying on accurate knowledge of the true excitation flip angles, as is the case of mapping using a spoiled gradient recalled echo sequence.
12 August 2026 in Magnetic Resonance in Medicine
ETElizabeth M. Tunnicliffe
Purpose: Assess the impact of incomplete spoiling and spatial saturation on mapping using the variable flip angle (VFA) spoiled gradient recalled echo sequence (SPGR). Develop a correction for incomplete spoiling that results in an accurate estimate of , essential for quantitative MRI applications. Methods: A correction factor, derived from extended phase graph simulations, was applied to the measured SPGR signal to account for deviations from the theoretical steady‐state signal. An iterative fitting process was used, refining the incomplete spoiling correction factor at each step based on the updated estimate. The incomplete spoiling correction method was validated against inversion recovery spin echo in phantom experiments and applied to in vivo data at 3T. Additionally, the hypothesis that spatial saturation disrupts the steady‐state was also tested and validated in a phantom. Results: Without a correction, the median error was +7.4% (IQR [4.4, 9.6]%) in both simulations and phantom experiments. After applying the correction, the median error decreased to −0.3% (IQR [−2.5, 2.1]%). In vivo, incomplete spoiling caused overestimation of 10–50 ms depending on inhomogeneity. Spatial saturation induced on average a −10% bias. Conclusion: A correction for incomplete spoiling is essential to achieve an accurate measure of using the VFA SPGR method, addressing systematic overestimation when using this mapping technique. Furthermore, other mechanisms that may disrupt the steady‐state signal, such as spatial saturation, should be considered.