With computing demand continuously increasing, data centers in extreme-climatic regions typified by the Middle East and North Africa with high daytime temperatures and large diurnal temperature swings face challenges including persistently high cooling energy consumption and a temporal mismatch between computing-driven cooling demand and the availability of natural cooling resources. Considering the regional climatic characteristics, a novel thermal management structure integrating phase-change materials (PCM), cooling towers, and heat pumps is proposed. By leveraging the thermal buffering capability of PCM together with the cooling tower’s nighttime natural cooling potential, peak shaving and valley filling for cooling is achieved, which alleviates the temporal mismatch between computing-driven cooling demand and availability of natural cooling resources and increases the natural cooling resources utilization. Furthermore, in order to reveal the coupling interaction between computing workloads, electric power consumption, and cooling requirements in data centers, a ”computing-electrical-thermal” coordinated optimization model is proposed to reduce economic cost and optimize the operation strategy of multi-energy devices. Considering the proposed coordinated optimization model features strong variable coupling and nonlinear characteristics, which cause parameter-propagation delays when conventional hierarchical solution methods are applied, a global solution algorithm is proposed to jointly solve the model. Taking a certain data center as a case study, compared with traditional air-liquid cooling systems, the novel thermal management system can significantly reduce the cooling power consumption. Compared with existing electrical–thermal model, the daily operating cost is decreased by approximately 5% by using the proposed computing–electrical–thermal coordinated strategy.

3 February 2026 in SSRN Electronic Journal
Verified
Preprint
Open access
ZZZichen Zhang
Zichen Zhang
ZLZhengtian Li
Zhengtian Li
ZLZhuonan Lin
Zhuonan Lin
LGLanxuan Guo
Lanxuan Guo
ZFZhongnan Feng
Zhongnan Feng
Diaa-Eldin A. MansourDiaa-Eldin A. Mansour
Diaa-Eldin A. Mansour
With computing demand continuously increasing, data centers in extreme-climate regions typified by the Middle East and North Africa (MENA) face challenges including persistently high cooling energy consumption and a temporal mismatch between computing-driven cooling demand and the availability of natural cooling resources. Considering the regional climatic characteristics of high daytime temperatures and large diurnal temperature swings, a novel thermal management structure integrating phase-change materials (PCM), cooling towers, and heat pumps is proposed. By leveraging the thermal buffering capability of PCM together with the cooling tower’s nighttime natural cooling potential, peak shaving and valley filling for cooling is achieved, which alleviates the temporal mismatch between computing-driven cooling demand and availability of natural cooling resources and increases the natural cooling resources utilization. Furthermore, to coordinate the coupled interactions among transferable computing workloads, electricity pricing, and natural cooling resources in the novel structure, a “computing-electrical-thermal” coordinated optimization model is proposed to reduce electricity cost and optimize the allocation of cooling resources. Since the proposed coordinated optimization model features strong variable coupling and nonlinear characteristics, which cause parameter-propagation delays when conventional hierarchical solution methods are applied, a global solution algorithm is proposed to jointly optimize key variables, including cooling tower power, heat-pump power, and computing workloads migration. Considering a certain data center as a case study, compared with a conventional air–liquid cooling system, electricity consumption is reduced by 17% and the daily operating cost is decreased by USD 2,075 by using the novel thermal management structure. In addition, compared with a conventional electrical–thermal coordination model, the daily operating cost is decreased by USD 556 by using the “computing–electrical–thermal” coordinated optimization model”.