Paul Raczeck

Paul Raczeck

Auto-generated profile, based on publicly available information

Paul Raczeck

Clinic of Diagnostic and Interventional Radiology, Saarland University Medical Center

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 June 2017 in American Journal of Neuroradiology
Verified
Journal Article
Open access
PDF file
GSG.K. Schneider
G.K. Schneider
JSJ. Stroeder
J. Stroeder
GRG. Roditi
G. Roditi
CCC. Colosimo
C. Colosimo
PAP. Armstrong
P. Armstrong
PRP. Raczeck
P. Raczeck
BACKGROUND AND PURPOSE: Signal intensity increases possibly suggestive of gadolinium retention have recently been reported on unenhanced T1-weighted images of the pediatric brain following multiple exposures to gadolinium-based MR contrast agents. Our aim was to determine whether T1 signal changes suggestive of gadolinium deposition occur in the brains of pediatric nonneurologic patients after multiple exposures to gadobenate dimeglumine. MATERIALS AND METHODS: Thirty-four nonneurologic patients (group 1; 17 males/17 females; mean age, 7.18 years) who received between 5 and 15 injections (mean, 7.8 injections) of 0.05 mmol/kg of gadobenate during a mean of 2.24 years were compared with 24 control patients (group 2; 16 males/8 females; mean age, 8.78 years) who had never received gadolinium-based contrast agents. Exposure to gadobenate was for diagnosis and therapy monitoring. Five blinded readers independently determined the signal intensity at ROIs in the dentate nucleus, globus pallidus, pons, and thalamus on unenhanced T1-weighted spin-echo images from both groups. Unpaired t tests were used to compare signal-intensity values and dentate nucleus–pons and globus pallidus–thalamus signal-intensity ratios between groups 1 and 2. RESULTS: Mean signal-intensity values in the dentate nucleus, globus pallidus, pons, and thalamus of gadobenate-exposed patients ranged from 366.4 to 389.2, 360.5 to 392.9, 370.5 to 374.9, and 356.9 to 371.0, respectively. Corresponding values in gadolinium-based contrast agent–na|fkve subjects were not significantly different (P > .05). Similarly, no significant differences were noted by any reader for comparisons of the dentate nucleus–pons signal-intensity ratios. One reader noted a difference in the mean globus pallidus–thalamus signal-intensity ratios (1.06 ± 0.006 versus 1.02 ± 0.009, P = .002), but this reflected nonsignificantly higher T1 signal in the thalamus of control subjects. The number of exposures and the interval between the first and last exposures did not influence signal-intensity values. CONCLUSIONS: Signal-intensity increases potentially indicative of gadolinium deposition are not seen in pediatric nonneurologic patients after multiple exposures to low-dose gadobenate.

1 March 2016 in American Journal of Roentgenology
Verified
Journal Article
Closed access
PRPaul Raczeck
Paul Raczeck
PMPeter Minko
Peter Minko
SGStefan Graeber
Stefan Graeber
PFPeter Fries
Peter Fries
RSRoland Seidel
Roland Seidel
JSJonas Stroeder
Jonas Stroeder
OBJECTIVE. The purpose of this study was to prospectively compare the effect of inspiration and resting expiratory position on contrast enhancement in pulmonary CT angiography (CTA) in a randomized clinical trial. SUBJECTS AND METHODS. In accordance with a power analysis performed before the study, we included 28 consecutive patients referred for evaluation of suspected pulmonary embolism in this prospective study. Patients were randomly assigned to perform either inspiration (n = 14; six men, eight women; mean age [SD], 38.1 ± 9.8 years) or resting expiratory position (n = 14; six men, eight women; mean age: 42.1 ± 9.2 years). All patients were scanned in a standardized supine position and scanning parameters were kept constant. Contrast medium was injected automatically with bolus tracking. Objective pulmonary vessel attenuation was quantified with digital measurement. Results were analyzed by using the unpaired t test and chi-square test. RESULTS. Patients in the resting expiratory position showed sign...

4 November 2021 in Investigative Radiology
Verified
Journal Article
Closed access
PRPaul Raczeck
Paul Raczeck
FFFelix Frenzel
Felix Frenzel
TWTobias Woerner
Tobias Woerner
SGStefan Graeber
Stefan Graeber
RBRainer M. Bohle
Rainer M. Bohle
GSGuenther K. Schneider
Guenther K. Schneider
Objectives: The aim of this study was to compare the diagnostic accuracy of apparent diffusion coefficient (ADC) ratios as a monoparametric magnetic resonance imaging (MRI) protocol for the detection of prostate cancer (PCa) with the established multiparametric (mp) MRI at 3.0 T. Materials and Methods: According to power analysis, 52 male patients were included in this monocenter study with prospective data collection and retrospective, blinded multireader image analysis. The study was approved by the local ethics committee. Patients were recruited from January to December 2020. Based on mpMRI findings, patients underwent in-bore MR biopsy or prostatectomy for histopathologic correlation of suspicious lesions. Three readers, blinded to the histopathologic results and images of mpMRI, independently evaluated ADC maps for the detection of PCa. The ADC ratio was defined as the lowest signal intensity (SI) of lesions divided by the SI of normal tissue in the zone of origin. Predictive accuracy of multiparametric and monoparametric MRI were compared using logistic regression analysis. Moreover, both protocols were compared applying goodness-of-fit analysis with the Hosmer-Lemeshow test for continuous ADC ratios and Pearson χ2 test for binary decision calls, correlation analysis with Spearman ρ and intraclass correlation coefficients, as well as noninferiority assessment with a TOST (“two one-sided test”). Results: Eighty-one histopathologically proven, unique PCa lesions (Gleason score [GS] ≥ 3 + 3) in 52 patients could be unequivocally correlated, with 57 clinically significant (cs) PCa lesions (GS ≥ 3 + 4). Multiparametric MRI detected 95%, and monoparametric ADC detected ratios 91% to 93% of csPCa. Noninferiority of monoparametric MRI was confirmed by TOST (P < 0.05 for all comparisons). Logistic regression analysis revealed comparable predictive diagnostic accuracy of ADC ratios (73.7%–87.8%) versus mpMRI (72.2%–84.7%). Spearman rank correlation coefficient for PCa aggressiveness revealed satisfactory correlation of ADC ratios (P < 0.013 for all correlations). The Hosmer-Lemeshow test for the logistic regression analysis for continuous ADC ratios indicated adequate predictive accuracy (P = 0.55–0.87), and the Pearson χ2 test showed satisfactory goodness of fit (P = 0.35–0.69, χ2 = 0.16–0.87). Conclusions: Normalized ADC ratios based on advanced DWI are noninferior to mpMRI at 3.0 T for the detection of csPCa in a preselected patient cohort and proved a fast and accurate assessment tool, thus showing a potential prospect of easing the development of future screening methods for PCa.

7 April 2021 in Journal of Magnetic Resonance Imaging
Verified
Journal Article
Open access
PDF file
PRPaul Raczeck
Paul Raczeck
PFPeter Fries
Peter Fries
AMAlexander Massmann
Alexander Massmann
PMPeter Minko
Peter Minko
FFFelix Frenzel
Felix Frenzel
GSGuenther K. Schneider
Guenther K. Schneider
Background: For peripheral artery disease (PAD), MR angiography (MRA) is a well‐established diagnostic modality providing morphologic and dynamic information comparable to digital subtraction angiography (DSA). However, relatively large amounts of contrast agents are necessary to achieve this.Purpose: To evaluate the diagnostic accuracy of time‐resolved 4D MR‐angiography with interleaved stochastic trajectories (TWIST‐MRA) by using maximum intensity projections (MIPs) of dynamic images acquired with reduced doses of contrast agent.Study Type: Retrospective.Population: Forty adult PAD patients yielding 1088 artery segments.Field Strength/Sequence: A 3.0 T, time‐resolved 4D MR‐angiography with TWIST‐MRA and MIP of dynamic images.Assessment: DSA was available in 14 patients (256 artery segments) and used as reference standard. Three‐segmental MIP reconstructions of TWIST‐images after administration of 3 mL of gadolinium‐based contrast agent (Gadoteridol/Prohance®, 0.5 M) per anatomical level (pelvis, thighs, and lower legs) yielded 256 artery segments for correlation between MRA and DSA. Three independent observers rated image quality (scale: 1 [nondiagnostic] to 4 [excellent]) and the degree of venous overlay (scale: 0 [none] to 2 [significant]) for all segments. Diagnostic accuracy for the detection of >50% stenosis and artery occlusion was calculated for all observers.Statistical Tests: Binary classification test (sensitivity, specificity, positive/negative predictive values, diagnostic accuracy). Intraclass correlation coefficients (ICCs), logistic regression analysis with comparison of areas under the receiver‐operating‐characteristics (ROC) curves (AUCs) with the DeLong method. Bland–Altman‐comparison.Results: High diagnostic performance was achieved for the detection of >50% stenosis (sensitivity 92.9% [84.3–99.9% (95%‐CI)] and specificity 98.5% [95.7–99.8% (95%‐CI)]) and artery occlusion (sensitivity 93.1% [77.2–99.2% (95%‐CI)] and specificity 99.1% [96.9–99.9% (95%‐CI)]). Inter‐reader agreement was excellent with ICC values ranging from 0.95 to 1.0 for >50% artery stenosis and occlusion. Image quality was good to excellent for both readers (3.41 ± 0.72, 3.33 ± 0.65, and 3.38 ± 0.61 [mean ± SD]) with good correlation between observer ratings (ICC 0.71–0.81). No significant venous overlay was observed (0.06 ± 0.24, 0.23 ± 0.43 and 0.11 ± 0.45 [mean ± SD]).Data Conclusion: MIPs of dynamic TWIST‐MRA offer a promising diagnostic alternative necessitating only reduced amounts (50%) of gadolinium‐based contrast agents for the entire runoff vasculature.Evidence Level: 3Technical Efficacy: Stage 2

2 November 2020 in Indian Journal of Surgery
Verified
Journal Article
Open access
PDF file
PJPhilippe Jagoda
Philippe Jagoda
JSJonas Stroeder
Jonas Stroeder
ABArno Buecker
Arno Buecker
JGJoshua Gawlitza
Joshua Gawlitza
FFFelix Frenzel
Felix Frenzel
PRPaul Raczeck
Paul Raczeck
For students, early hands-on experience is very limited and often non-existent during study time. Thus, we aimed to evaluate the progress of inexperienced medical students in successfully establishing an ultrasound-guided vessel access. One brief, condensed single teaching lesson in a prior to post-teaching scenario was performed using an inexpensive, self-made phantom model. In this prospective study, medical students (n = 11) with no experience in ultrasound imaging performed an ultrasound-guided vessel access simulated by a gelatin-based phantom model. Success rates and time of procedures were measured. Afterwards, participants underwent dedicated supervised teaching in a single lesson (duration 30 min) with both theoretical information given and practical training skills shown. Then, every student performed the very same procedure again and results were compared with paired t test. Success rate of guide wire placement rose from 36.4 (4/11) to 100%. Mean number of attempts significantly decreased with 2.5 SD1.3 before and 1.2 SD0.4 after teaching (p < 0.05). Overall time to successful guide wire placement improved from 291 SD8 to 151 SD37 s (p < 0.05). With already limited training time and opportunities available during medical education, short and simple, but highly effective training tools are invaluable. With the help of an inexpensive, self-made gelatin-based phantom model for ultrasound-guided vascular access, medical students demonstrate significantly improved practical puncture skills after only one brief, condensed teaching lesson and thus an important progress with regard to their future clinical routine. The performance of ultrasound-guided vascular access can be highly improved for inexperienced medical students by applying one short teaching session using an inexpensive, self-made phantom model.

22 February 2021 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
GSGuenther Schneider
Guenther Schneider
AMAlexander Massmann
Alexander Massmann
PFPeter Fries
Peter Fries
FFFelix Frenzel
Felix Frenzel
ABArno Buecker
Arno Buecker
PRPaul Raczeck
Paul Raczeck
Background. This paper aimed to prospectively evaluate the safety of embolization therapy of pulmonary arteriovenous malformations (PAVMs) for the detection of cerebral infarctions by pre- and post-interventional MRI. Method One hundred and five patients (male/female = 44/61; mean age 48.6+/−15.8; range 5–86) with pre-diagnosed PAVMs on contrast-enhanced MRA underwent embolization therapy. The number of PAVMs treated in each patient ranged from 1–8 PAVMs. Depending on the size and localization of the feeding arteries, either Nester-Coils or Amplatzer vascular plugs were used for embolization therapy. cMRI was performed immediately before, and at the 4 h and 3-month post-embolization therapy. Detection of peri-interventional cerebral emboli was performed via T2w and DWI sequences using three different b-values, with calculation of ADC maps. Results Embolization did not show any post-/peri-interventional, newly developed ischemic lesions in the brain. Only one patient who underwent re-embolization and was previously treated with tungsten coils that corroded over time showed newly developed, small, diffuse emboli in the post-interventional DWI sequence. This patient already had several episodes of brain emboli before re-treatment due to the corroded coils, and during treatment, when passing the corroded coils, experienced additional small, clinically inconspicuous brain emboli. However, this complication was anticipated but accepted, since the vessel had to be occluded distally. Conclusion Catheter-based embolization of PAVMs is a safe method for treatment and does not result in clinically inconspicuous cerebral ischemia, which was not demonstrated previously.