2 June 2020 in Journal of Analytical Atomic Spectrometry
The matrix effects in MIP OES arising in the presence of elements with Eion 5.13–9.39 eV (Na, Cu, Pb, Cd, Zn) depending on the concentration, nebulization flow rate, and plasma power were studied.
8 June 2022 in Journal of Analytical Atomic Spectrometry
We studied the effect of O2 content in the range of 0.1–1.2% in plasma gas on the plasma characteristics, the analytical signal and the intensity of the molecular species in nitrogen MIP. The plasma temperature decreases from 4.50 × 103 to 4.39 × 103 K with increasing O2 content. The Mg(II)/Mg(I) intensity ratio decreases from 1.14 to 0.90, and the electron density decreases from 1.16 × 1014 to 0.85 × 1014. The intensities of N2, N2 + and NH decrease, and the NO and OH intensities increase when O2 is added. The influence of O2 content on the intensity of several atomic and ionic emission lines (covering Esum values from 2.1 to 15.4 eV) of 12 elements has been studied. The intensity of atomic lines with Esum values lower than 6 eV was enhanced in the presence of O2 but it was suppressed for the ionic lines tested. It was shown that the O2 addition leads to a decrease in the LOD calculated from atomic lines and to an increase in the LOD calculated from ionic lines.
1 January 2024 in Аналитика и контроль
In 2023, optical spectrometers Grand were included in the Russian State Register of Measuring Instruments under No. 89108-23 as a tool for measuring the mass fractions of analytes in natural and industrial materials. These spectrometers are manufactured by VMK-Optoelektronika company in ten modifications, nine of which are atomic emission spectrometers and one is an atomic absorption spectrometer: Atomic emission spectrometers a. Grand-Globula, Grand-Kristall, and Grand-Express arc and spark discharge spectrometers for direct (without preliminary chemical preparation) analysis of powder samples and metals; b. Grand-Potok arc discharge spectrometer for rapid analysis of powder samples using the spill-injection method; c. Grand-Expert and Grand-Favorit vacuum argon spark discharge spectrometers for rapid analysis of metals and alloys; d. Grand-MP nitrogen microwave plasma spectrometer and Grand-ICP inductively coupled argon plasma spectrometer for analysis of liquid samples; e. Grand-Pavlin flame emission spectrometer for determination of alkali and alkaline earth elements in solutions. Grand-AAS high-resolution continuum source electrothermal atomic absorption spectrometer for simultaneous multielement determination in liquids. Atomic emission spectrometers have various spectrum excitation sources based on almost all atomization and excitation methods known in atomic emission spectrometry. Grand-AAS atomic absorption spectrometer is the world's first commercial instrument that allows the simultaneous determination of more than 40 elements in a liquid in one electrothermal atomization cycle with analytical performance close to that of modern electrothermal atomic absorption spectrometers for the sequential determination of elements.
15 February 2019 in Zavodskaya Laboratoriya. Diagnostika Materialov
It is known that the working properties of motor oil are determined by the presence of some elements of the periodic table. The properties of oil can vary significantly over time due to exposure to both high and extremely low pressures and temperatures. To ensure uninterrupted long-term operation of equipment, it is necessary to monitor various indicators of oil, including the determination of wear metals on a regular basis. Two methods of determining wear metals are most widely used: an electric arc with a rotating graphite disk and inductively coupled plasma. The goal of the work was to determine wear metals in oil using a microwave nitrogen plasma source and an «Ékspress» spectrometer according to ASTM D5185-09 method. Microwave plasma was produced using an industrial magnetron with a frequency of 2.5 GHz and a microwave resonator which provided toroidal plasma shape. Nitrogen (purity of 99.6%) was used as a plasma-forming gas. In accordance with the mentioned procedure, a series of wear metal samples was prepared by adding metal oxides to the base oil for comparison with the control experiment. After that, the solutions were diluted 1:10 by weight with kerosene to eliminate the difference in viscosity of the samples and ensure their spraying using a pneumatic spray. The spectrometer allows simultaneous recording of spectra in the region of 190 – 360 and 390 – 540 nm with an integration time of 70 msec. The intensity of C2and CN molecular bands was reduced by introducing air into the intermediate flame of the burner. The constructed calibration graphs for determination of Al, Pb, Fe, Cu, Cr, Cn were used in analysis of the control sample. It is shown that wear metals in oil can be determined using microwave plasma as a source of spectrum excitation.
1 January 2021 in Аналитика и контроль
NUNovosibirsk State Technical University
Novosibirsk State Technical University
One trend in the development of integral atomic emission spectral analysis with low spectral background excitation sources, such as inductively coupled or microwave plasma, is to increase the dynamic range of spectrum recording systems based on photodetector arrays. To achieve low detection limits, it is necessary to use photodetector arrays with low reading noise. The dynamic range of a single readout of such photodetector arrays usually does not exceed four orders of magnitude. The dynamic range increase due to the accumulation of spectra from multiple acquisition leads to a quadratic increase in the measurement time. This method does not allow one to cover the entire dynamic range of spectral line intensities of inductively coupled or microwave plasma (which can reach seven orders of magnitude) while maintaining an acceptable total measurement time of a sample spectrum. As an alternative, it is proposed to increase the dynamic range toward higher line intensities by using two different alternating accumulation times during measurement. The objective of this study is to implement the proposed recording mode in MAES analyzers based on BLPP-2000 and BLPP-4000 photodetector arrays in order to increase the dynamic range of recorded spectral lines. Dependences of the signal-to-noise ratio and the dynamic range of spectral lines recorded in integral atomic emission spectrometry on the accumulation time, the total measurement time, the spectral background level, and the photodetector array parameters are obtained. It is shown theoretically that the use of the recording mode with alternating different accumulation times should increase the dynamic range of BLPP-2000 and BLPP-4000 photodetector arrays by two orders of magnitude. The dynamic range of spectral line intensities of a hollow-cathode lamp is shown experimentally to increase by two orders of magnitude (to five orders of magnitude).
1 January 2019 in Аналитика и контроль
L“Llc “Vmk-Optoelektronika”
Llc “Vmk-Optoelektronika”
+4
СПЕКТРОМЕТР С МИКРОВОЛНОВОЙ ПЛАЗМОЙ «ГРАНД-СВЧ» ДЛЯ АТОМНО-ЭМИССИОННОГО АНАЛИЗА