Jiang

Jiang

Auto-generated profile, based on publicly available information

Jiang

Spectral Energies

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 October 2017 in Applied Optics
Verified
Journal Article
Open access
PDF file
NDNicholas J. DeLuca
Nicholas J. DeLuca
RMRichard B. Miles
Richard B. Miles
NJNaibo Jiang
Naibo Jiang
WKWaruna Kulatilaka
Waruna Kulatilaka
APAnil K. Patnaik
Anil K. Patnaik
JGJames R. Gord
James R. Gord
We report the use of femtosecond laser electronic excitation tagging (FLEET) for velocimetry at a 100-kHz imaging rate. Sequential, single-shot, quantitative velocity profiles of an underexpanded supersonic nitrogen jet were captured at a 100-kHz rate. The signal and lifetime characteristics of the FLEET emission were investigated in a methane flame above a Hencken burner at varying equivalence ratios, and room temperature gas mixtures involving air, methane, and nitrogen. In the post-flame region of the Hencken burner, the emission lifetime was measured as two orders of magnitude lower than lab air conditions. Increasing the equivalence ratio above 1.1 leads to a change in behavior, with a doubled lifetime. By measuring the emission in a cold methane flow, a short-lived signal was measured that decayed after the first microsecond. As a proof of concept for velocimetry in a reacting environment, the exhaust of a pulsed detonator was measured by FLEET. Quantitative velocity information was obtained that corresponded to a maximum centerline velocity of 1800 m/s for the detonation wave. Extension of FLEET to larger scale, complex flow environments is now a viable option.

10 February 2018 in Applied Physics B
Verified
Journal Article
Closed access
PDF file
JEJordi Estevadeordal
Jordi Estevadeordal
NJNaibo Jiang
Naibo Jiang
ACAndrew D. Cutler
Andrew D. Cutler
JFJosef J. Felver
Josef J. Felver
MSMikhail N. Slipchenko
Mikhail N. Slipchenko
SRSukesh Roy
Sukesh Roy

14 March 2022 in Applied Optics
Verified
Journal Article
Closed access
NJNaibo Jiang
Naibo Jiang
SGStephen W. Grib
Stephen W. Grib
PHPaul S. Hsu
Paul S. Hsu
MBMatthew Borg
Matthew Borg
SSS. Alexander Schumaker
S. Alexander Schumaker
SRSukesh Roy
Sukesh Roy
A 100 kHz krypton (Kr) tagging velocimetry (KTV) technique was demonstrated in a Mach-6 Ludwieg tube using a burst-mode laser-pumped optical parametric oscillator system. The single-beam KTV scheme at 212 nm produced an insufficient signal in this large hypersonic wind tunnel because of its low Kr seeding ( ≤ 5 % ), low static pressure ( ∼ 2.5 t o r r ), and long working distance ( ∼ 1 m ). To overcome these issues, a new scheme using two excitation beams was developed to enhance KTV performance. A 355 nm laser beam was combined with the 212 nm beam to promote efficient two-photon Kr excitation at 212 nm, and increase the probability of 2 + 1 resonant-enhanced multiphoton ionization by adding a 355 nm beam. A signal enhancement of approximately six times was obtained. Using this two-excitation beam approach, strong long-lasting KTV was successfully demonstrated at a 100 kHz repetition rate in a Mach-6 flow.

27 September 2020 in Applied Physics B
Verified
Journal Article
Closed access
PDF file
CFChristopher A. Fugger
Christopher A. Fugger
PHPaul S. Hsu
Paul S. Hsu
NJNaibo Jiang
Naibo Jiang
TYTongxun Yi
Tongxun Yi
MSMikhail N. Slipchenko
Mikhail N. Slipchenko
SRSukesh Roy
Sukesh Roy

4 February 2019 in Applied Optics
Verified
Journal Article
Closed access
PDF file
NJNaibo Jiang
Naibo Jiang
PHPaul S. Hsu
Paul S. Hsu
PDPaul M. Danehy
Paul M. Danehy
ZZZhili Zhang
Zhili Zhang
SRSukesh Roy
Sukesh Roy
Two-dimensional (2D) Rayleigh scattering (RS) imaging at an ultrahigh repetition rate of 100 kHz is demonstrated in non-reacting flows employing a high-energy burst-mode laser system. Image sequences of flow mixture fraction were directly derived from high-speed RS images. Additionally, a 2D instantaneous flow velocity field at 100 kHz was obtained through optical-flow-based analysis of the RS images. In further analysis of both the mixture fraction and flow velocity field, the result for the centerline mixture fraction agreed well with the scaling law. The demonstrated high-speed RS technique in conjunction with optical-flow-based analysis provides non-intrusive, simultaneous measurements of the flow mixing and velocity field, extending the measurement capability of the RS technique to high-speed non-reacting and reacting flows.

31 August 2018 in Measurement Science and Technology
Verified
Journal Article
Closed access
PDF file
RBRoss A Burns
Ross A Burns
PDPaul M Danehy
Paul M Danehy
NJNaibo Jiang
Naibo Jiang
MSMikhail N Slipchenko
Mikhail N Slipchenko
JFJosef Felver
Josef Felver
SRSukesh Roy
Sukesh Roy
Picosecond laser electronic excitation tagging (PLEET) is implemented in a large-scale wind tunnel for the first time. High-speed, unseeded velocimetry is performed in the NASA Langley 0.3-m Transonic Cryogenic Tunnel; repetition rates up to 25 kHz are tested. Velocity measurements are assessed for accuracy and precision. Measurement errors vary in the range of 0.6–1.2%, while the instrument precision is found to lie between 1.2 m/s and 2 m/s and exhibits little variation over the full operating range of the facility. An examination of the signal intensity reveals little to no thermodynamic dependence, and the signal lifetimes exhibit an inverse dependence on both pressure and temperature. The PLEET signal is demonstrated to be largely unaffected by buoyancy despite the large temperature rise. The velocity dynamic range of the measurements is found to be a factor of at least 200 in these experiments with the capacity to measure much higher velocities as well. The spatial resolution of the velocity measurements is found to lie between 2 and 2.7 mm, and the maximum frequency response is 12.5 kHz with the ability to resolve up to 50 kHz with the current measurement system. Overall measurement uncertainties in the streamwise velocity are found to lie between 4% and 4.8% for high to low velocities, while the uncertainty in the transverse velocity is less than 6 m/s. The measurement uncertainties are found to be dominated by systematic errors in the calibration procedure, which could be improved in future experiments.