6 May 2022 in Analytical Methods
Ruxolitinib (RUX), a small molecule inhibitor of JAK1/JAK2, has been identified as the possible novel targeted agent for the treatment of hemophagocytic lymphohistiocytosis (HLH). However, due to the lack of randomized clinical trials (RCTs), it is extremely difficult to determine the effective therapeutic dose for RUX in HLH patients, especially in pediatric patients. At the same time, the clinical response of pediatric patients to RUX varies greatly among individuals according to several case reports. Therefore, it is imperative to investigate the pharmacokinetic and pharmacodynamic characteristics of RUX in HLH children, and this must be based on a satisfactory method to determine the concentration of RUX. Owing to several limits of published analytical methods, herein, we describe a novel liquid chromatography tandem mass spectrometry (LC-MS/MS) method for monitoring RUX in children's plasma samples. The protein precipitation method using methanol was used for sample cleanup. The analytes were separated by gradient elution in which 2.0 mM ammonium acetate in distilled water and acetonitrile were used as mobile phases. In the positive electrospray ionization (ESI+) mode, the m/z 307.1 → 186.0 and 316.1 → 185.9 ion pair transitions of RUX and RUX-d9 were used for the qualitative and quantitative analysis, respectively. The calibration curves of RUX were linear in the concentration range from 0.5 to 400 ng mL−1. The intra- and inter-batch precision, accuracy, recovery, dilution completeness, and stability of this method were all within acceptable standards, and no matrix effects or residues were found. This method was successfully applied to the clinical pharmacokinetic study of RUX in 32 children with HLH. The pharmacokinetic parameters of HLH children after a single dose of RUX and the steady state plasma concentration after multiple administrations were proposed through this method. Most importantly, it was found that the age and serum creatinine (SCr) of children with HLH had a significant and complex impact on the in vivo process of RUX after the single as well as multiple administrations of RUX.
13 December 2022 in Cancer Chemotherapy and Pharmacology
17 October 2023 in Acta Chromatographica
In this work, a simple and rapid high performance liquid chromatography tandem mass spectrometry (HPLC-MS/MS) method was developed and validated to carry out the simultaneous measurement of busulfan (BU) and phenytoin (PHT) in the plasma of children. In this method, plasma sample could be prepared by one-step protein precipitation using 1 mL of methanol/water (1:1, v/v). After centrifugation (14,500 rpm, 5 min, 4 °C), 10 μL of the supernatant was injected into a Hypersil Gold C18 column (150 × 2.1 mm, 5 μm, Thermo Fisher Scientific) for separation by gradient elution. Quantification was carried out using multiple reactions monitoring (MRM) under positive scan mode. In the method verification, the calibration curves of BU and PHT showed satisfactory linearity (r > 0.99) at the concentration ranging from 0.02 to 20 μg mL−1. The accuracy and precision were tested at four concentration levels (including the LLOQ level) with the relative error (RE) ranging from −0.80% to 11.45% and coefficient of variation (CV) between 0.93% and 7.74%. There was no pronounced matrix effect to interfere with the quantitative analysis. Compared to determine BU and PHT using two individual methods, less pre-treatment process, labor and blood sample volume are required in this proposed method. Finally, this method was successfully applied to the therapeutic drug monitoring of BU and PHT for children underwent hematological stem cell transplantation.
9 October 2024 in Alimentary Pharmacology & Therapeutics