Fuad A. Al-Sanabani

Fuad A. Al-Sanabani

Auto-generated profile, based on publicly available information

Fuad A. Al-Sanabani

Department of Prosthetic Dental Sciences, College of Dentistry, Jazan University, Jazan, Saudi Arabia

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 September 2023 in Medical Science Monitor
Verified
Journal Article
Open access
BABandar AL-Makramani
Bandar AL-Makramani
Mohammed SayedMohammed Sayed
Mohammed Sayed
FAFuad A. Al-Sanabani
Fuad A. Al-Sanabani
KMKhurshid Mattoo
Khurshid Mattoo
NANasser M. Alqahtani
Nasser M. Alqahtani
RERami Eshaq
Rami Eshaq
Background: The aim of this study was to assess and compare the vertical/horizontal dimensions and occlusal accuracy of non-working/opposing casts obtained from three different impression materials and 3D print cast.Material/Methods: Dentulous Master models simulating a case of a fixed dental prosthesis were mounted on an articulator (con-trol group). Opposing mandibular casts obtained from three different impression materials [Hydrogum Alginate (Conventional), Hydrocolor 5 (Extended-Pour Alginate), FreeAlgin (Alginate Alternative)] and 3-dimensional print constituted test groups [Gp AL(C)], [Gp AL(E)], [Gp AL(F)] and [Gp 3D-C], respectively. Three points, anterior vertical (AV), posterior vertical (PV), and anteroposterior (AP) were compared for dimensional accuracy among casts. Occlusal accuracy was analyzed on Medit Link software at 3 teeth (#13, #17, and #27). After calculating means for each group, the differences were calculated at probability value of P pound 0.05 using the single-sample t test, ANOVA, and Tukey test.Results: The dimensions were significantly different from those of the mounted master models except in Gp AL(E) and Gp AL(F) at AV dimension and Gp AL(E) at AP dimension (P>0.05). A statistically significant difference of the er-ror of means among the 4 tested groups [Gp AL(C), Gp AL(E), Gp AL(F), and Gp 3D-C] were detected only at 2 dimensions (AV and PV) between the Gp AL(E) and Gp 3D-C and between Gp AL(F) and Gp 3D-C groups. Other groups showed no significant differences.Conclusions: The opposing casts obtained from the extended-pour alginate and alginate alternative impression materials showed higher occlusal accuracy compared to conventional alginate and 3D printed casts.

28 November 2024 in Medical Science Monitor
Verified
Journal Article
Open access
ASAbdulelah Sameer Sindi
Abdulelah Sameer Sindi
HOHanan Salem A. Otudi
Hanan Salem A. Otudi
AMAsma Ahmed A. Muslihi
Asma Ahmed A. Muslihi
RARoaa Abdu Althurwi
Roaa Abdu Althurwi
Mohammed SayedMohammed Sayed
Mohammed Sayed
KMKhurshid Mattoo
Khurshid Mattoo
Background: A tooth preparation's clinical requirements and geometric configurations should take precedence over material characteristics when advocating for putty reline impression techniques for permanent restorations, since they require a technically sensitive spacer for light body elastomer. We evaluated the linear dimensional accuracy of vinyl polysiloxane-based putty reline impressions with different spacer acquisition techniques in shortspan and long-span fixed partial dentures (FPD). Material/Methods: A typodont tooth set simulated a 3-unit (short-span) and a 5-unit (long-span) FPD. Between respective prepared abutments, 31 coordinates were identified and measured based on angles (line/point) and surfaces (curved/flat). Sixty impressions (dual stage 2-step putty reline technique) were divided into 5 groups (n=12/group): group PP porary), and group MT (modified temporary), depending on spacer acquisition method. Coordinates measurements were conducted using a measuring microscope. Descriptive and inferential statistical tests (ANOVA, post hoc Tukey) determined between-group and within-group differences, at P <= 0.05 significance level. Results: In short-span FPD, compared with control, the number of significantly different coordinates group-wise were GP (4 coordinates), PP (2 coordinates), and PS, CT, and MT (1 each). In long-span FPD, compared with control, the number of significantly different coordinates group-wise were group GP (12 coordinates), group PP (10 coordinates), group PS (5 coordinates), and group CT and group MT (4 each). Conclusions: Different spacer acquisition methods produce varied thickness of spacers for relining of putty. CT and MT, when used as spacers, provided maximum accurate coordinates for angles (line/point) and surfaces (curved/flat).