Yu Chen

Yu Chen

Auto-generated profile, based on publicly available information

Yu Chen

Department of Automation, Tsinghua University, Beijing, China

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 September 2024 in IEEE Transactions on Robotics
Verified
Journal Article
Closed access
YCYu Chen
Yu Chen
SMShu Miao
Shu Miao
GCGong Chen
Gong Chen
JYJing Ye
Jing Ye
CFChenlong Fu
Chenlong Fu
XLXiang Li
Xiang Li
One of the typical purposes of using lower-limb exoskeleton robots is to provide assistance to the wearer by supporting their weight and augmenting their physical capabilities according to a given task and human motion intentions. The generalizability of robots across different wearers in multiple tasks is important to ensure that the robot can provide correct and effective assistance in actual implementation. However, most lower-limb exoskeleton robots exhibit only limited generalizability. Therefore, this paper proposes a human-in-the-loop learning and adaptation framework for exoskeleton robots to improve their performance in various tasks and for different wearers. To suit different wearers, an individualized walking trajectory is generated online using dynamic movement primitives and Bayes optimization. To accommodate various tasks, a task translator is constructed using a neural network to generalize a trajectory to more complex scenarios. These generalization techniques are integrated into a unified variable impedance model, which regulates the exoskeleton to provide assistance while ensuring safety. In addition, an anomaly detection network is developed to quantitatively evaluate the wearer's comfort, which is considered in the trajectory learning procedure and contributes to the relaxation of conflicts in impedance control. The proposed framework is easy to implement, because it requires proprioceptive sensors only to perform and deploy data-efficient learning schemes. This makes the exoskeleton practical for deployment in complex scenarios, accommodating different walking patterns, habits, tasks, and conflicts. Experiments and comparative studies on a lower-limb exoskeleton robot are performed to demonstrate the effectiveness of the proposed framework.

24 April 2025 in The International Journal of Robotics Research
Verified
Journal Article
Closed access
YCYu Chen
Yu Chen
SMShu Miao
Shu Miao
JYJing Ye
Jing Ye
GCGong Chen
Gong Chen
JCJianghua Cheng
Jianghua Cheng
XLXiang Li
Xiang Li
Several upper-limb exoskeleton robots have been developed for stroke rehabilitation, but their rather low level of individualized assistance typically limits their effectiveness and practicability. Individualized assistance involves an upper-limb exoskeleton robot continuously assessing feedback from a stroke patient and then meticulously adjusting interaction forces to suit specific conditions and online changes. This paper describes the development of a new upper-limb exoskeleton robot with a novel online generative capability that allows it to provide individualized assistance to support the rehabilitation training of stroke patients. Specifically, the upper-limb exoskeleton robot exploits generative models to customize the fine and fit trajectory for the patient, as medical conditions, responses, and comfort feedback during training generally differ between patients. This generative capability is integrated into the two working modes of the upper-limb exoskeleton robot: an active mirroring mode for patients who retain motor abilities on one side of the body and a passive following mode for patients who lack motor ability on both sides of the body. In addition, the upper-limb exoskeleton robot has three other attractive features. First, it has six degrees of freedom (DoFs), namely five active DoFs and one passive DoF, to assist the shoulder and the elbow joints and cover the full range of upper-limb movement. Second, most of its active joints are driven by series elastic actuators (SEAs) and a cable mechanism, which absorb energy and have low inertia. These compliantly driven high DoFs provide substantial flexibility and ensure hardware safety but require an effective controller. Thus, based on the singular perturbation approach, a model-based impedance controller is proposed to fully exploit the advantages of the hardware. Third, the safety of the upper-limb exoskeleton robot is guaranteed by its hardware and software. Regarding hardware, its SEAs are tolerant to impacts and have high backdrivability. Regarding software, online trajectory refinement is performed to regulate the assistance provided by the upper-limb exoskeleton robot, and an anomaly detection network is constructed to detect and relax physical conflicts between the upper-limb exoskeleton robot and the patient. The performance of the upper-limb exoskeleton robot was illustrated in experiments involving healthy subjects and stroke patients.

25 March 2026 in IEEE Robotics and Automation Letters
Verified
Journal Article
Closed access
YCYu Chen
Yu Chen
SMShu Miao
Shu Miao
CWChunyu Wu
Chunyu Wu
JMJingsong Mu
Jingsong Mu
BOBo Ouyang
Bo Ouyang
XLXiang Li
Xiang Li
Upper-limb exoskeletons are primarily designed to provide assistive support by accurately interpreting and responding to human intentions. In home-care scenarios, exoskeletons are expected to adapt their assistive configurations based on the semantic information of the task, adjusting appropriately in accordance with the nature of the object being manipulated. However, existing solutions often lack the ability to understand task semantics or collaboratively plan actions with the user, limiting their generalizability. To address this challenge, this letter introduces a semantic-aware framework that integrates large language models into the task planning framework, enabling the delivery of safe and intent-integrative assistance. The proposed approach begins with the exoskeleton operating in transparent mode to capture the wearer's intent during object grasping. Once semantic information is extracted from the task description, the system automatically configures appropriate assistive parameters. In addition, a diffusion-based anomaly detector is used to continuously monitor the state of human-robot interaction and trigger real-time replanning in response to detected anomalies. During task execution, online trajectory refinement and impedance control are used to ensure safety and regulate human-robot interaction. Experimental results demonstrate that the proposed method effectively aligns with the wearer's cognition, adapts to semantically varying tasks, and responds reliably to anomalies.