17 May 2022 in Optics Express
MQMuhammad Mohsin Qureshi
+3
In microscopic imaging of biological tissues, particularly real-time visualization of neuronal activities, rapid acquisition of volumetric images poses a prominent challenge. Typically, two-dimensional (2D) microscopy can be devised into an imaging system with 3D capability using any varifocal lens. Despite the conceptual simplicity, such an upgrade yet requires additional, complicated device components and usually suffers from a reduced acquisition rate, which is critical to properly document rapid neurophysiological dynamics. In this study, we implemented an electrically tunable lens (ETL) in the line-scan confocal microscopy (LSCM), enabling the volumetric acquisition at the rate of 20 frames per second with a maximum volume of interest of 315 × 315 × 80 µm3. The axial extent of point-spread-function (PSF) was 17.6 ± 1.6 µm and 90.4 ± 2.1 µm with the ETL operating in either stationary or resonant mode, respectively, revealing significant depth axial penetration by the resonant mode ETL microscopy. We further demonstrated the utilities of the ETL system by volume imaging of both cleared mouse brain ex vivo samples and in vivo brains. The current study showed a successful application of resonant ETL for constructing a high-performance 3D axially scanning LSCM (asLSCM) system. Such advances in rapid volumetric imaging would significantly enhance our understanding of various dynamic biological processes.
11 October 2021 in Optica
This publisher’s note reports that corrections were made to the funding and acknowledgments in Optica 8, 1092 (2021)OPTIC8 2334-2536 10.1364/OPTICA.422871 .
1 October 2025 in Neurophotonics
SignificanceRapid acquisition of high-resolution volumetric images has been critical to effectively monitor dynamic biological processes in vivo, yet it faces tradeoffs between image resolution, penetration depth, and imaging speed. These limitations hinder the ability to study rapid neurophysiological events such as cerebrovascular dynamics and cellular activity, highlighting the need for advanced high-speed 3D imaging system.AimTo address these challenges in volumetric imaging performances, we aimed to develop a high-speed volumetric imaging system capable of resolving fast biological dynamics with minimal compromise in spatial resolution or imaging depth.ApproachWe devised a rapid axially scanned and de-scanned (RASAD) scheme by integrating a TAG lens (tunable acoustic gradient index of refraction lens) into a line-scan confocal microscope. The TAG lens enabled axial (depth) scanning frequency at 70 kHz, allowing 3D projection imaging at rates up to 200 Hz with a detection depth of 135 μm while minimally sacrificing the image quality (i.e., a lateral resolution of ∼2.6 μm).ResultsWe validated its performance through in vitro imaging of spontaneously contracting cardiomyocyte aggregates, capturing real-time calcium transients and synchronized contractions, and through in vivo imaging of the mouse cortical tissue, where volumetric acquisition over a 450×450×100 μm3 region enabled quantification of blood flow velocities up to 3.64 mm/s across various vessel types.ConclusionsThe RASAD system enables high-speed, high-resolution 3D imaging of dynamic biological processes, providing a valuable tool for advancing studies of neurophysiological mechanisms and biomedical applications.
3 December 2021 in bioRxiv
In microscopic imaging of biological tissues, particularly real-time visualization of neuronal activities, rapid acquisition of volumetric images poses a prominent challenge. Typically, two-dimensional (2D) microscopy can be devised into an imaging system with 3D capability using any varifocal lens. Despite the conceptual simplicity, such an upgrade yet requires additional, complicated device components and suffers a reduced acquisition rate, which is critical to document neuronal dynamics properly. In this study, we implemented an electro-tunable lens (ETL) in the line-scan confocal microscopy, enabling the volumetric acquisition at the rate of 20 frames per second with the maximum volume of interest of 315 × 315 × 80 μm 3 . The axial extent of point-spread-function (PSF) was 17.6 ± 1.6 μm and 90.4 ± 2.1 μm with the ETL operating in either stationary or resonant mode, respectively, revealing significant depth elongation by the resonant mode ETL microscopy. We further demonstrated the utilities of the ETL system by volume imaging of cleared mouse brain ex vivo samples and in vivo brains. The current study foregrounds the successful application of resonant ETL for constructing a basis for a high-performance 3D line-scan confocal microscopy system, which will enhance our understanding of various dynamic biological processes.