Khuong Duy Mac

Khuong Duy Mac

Auto-generated profile, based on publicly available information

Khuong Duy Mac

Gwangju Institute of Science and Technology

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 August 2021 in Optica
Verified
Journal Article
Closed access
PDF file
MQMuhammad Mohsin Qureshi
Muhammad Mohsin Qureshi
YLYan Liu
Yan Liu
KMKhuong Duy Mac
Khuong Duy Mac
MKMinsung Kim
Minsung Kim
ASAbdul Mohaimen Safi
Abdul Mohaimen Safi
ECEuiheon Chung
Euiheon Chung
Speckle-based methods are popular non-invasive, label-free full-field optical techniques for imaging blood flow maps at single vessel resolution with a high temporal resolution. However, conventional speckle approaches cannot provide an absolute velocity map with magnitude and direction. Here, we report an optical speckle image velocimetry (OSIV) technique for measuring the quantitative blood flow vector map by utilizing particle image velocimetry with speckle cross-correlations. We demonstrate that our OSIV instrument has a linearity range up to 7 mm/s, higher than conventional optical methods. Our method can measure the absolute flow vector map at up to 190 Hz without sacrificing image size, and it eliminates the need for a high-speed camera/detector. We applied OSIV to image the blood flow in a mouse brain, and as a proof of concept, imaged real-time dynamic changes in the cortical blood flow field during the stroke process in vivo. Our wide-field quantitative flow measurement OSIV method without the need of tracers provides a valuable tool for studying the healthy and diseased brain.

17 May 2022 in Optics Express
Verified
Journal Article
Closed access
KMKhuong Duy Mac
Khuong Duy Mac
MQMuhammad Mohsin Qureshi
Muhammad Mohsin Qureshi
MNMyeongsu Na
Myeongsu Na
SCSunghoe Chang
Sunghoe Chang
TETae Joong Eom
Tae Joong Eom
ECEuiheon Chung
Euiheon Chung
In microscopic imaging of biological tissues, particularly real-time visualization of neuronal activities, rapid acquisition of volumetric images poses a prominent challenge. Typically, two-dimensional (2D) microscopy can be devised into an imaging system with 3D capability using any varifocal lens. Despite the conceptual simplicity, such an upgrade yet requires additional, complicated device components and usually suffers from a reduced acquisition rate, which is critical to properly document rapid neurophysiological dynamics. In this study, we implemented an electrically tunable lens (ETL) in the line-scan confocal microscopy (LSCM), enabling the volumetric acquisition at the rate of 20 frames per second with a maximum volume of interest of 315 × 315 × 80 µm3. The axial extent of point-spread-function (PSF) was 17.6 ± 1.6 µm and 90.4 ± 2.1 µm with the ETL operating in either stationary or resonant mode, respectively, revealing significant depth axial penetration by the resonant mode ETL microscopy. We further demonstrated the utilities of the ETL system by volume imaging of both cleared mouse brain ex vivo samples and in vivo brains. The current study showed a successful application of resonant ETL for constructing a high-performance 3D axially scanning LSCM (asLSCM) system. Such advances in rapid volumetric imaging would significantly enhance our understanding of various dynamic biological processes.

11 October 2021 in Optica
Verified
Journal Article
Open access
MQMuhammad Mohsin Qureshi
Muhammad Mohsin Qureshi
YLYan Liu
Yan Liu
KMKhuong Duy Mac
Khuong Duy Mac
MKMinsung Kim
Minsung Kim
ASAbdul Mohaimen Safi
Abdul Mohaimen Safi
ECEuiheon Chung
Euiheon Chung
This publisher’s note reports that corrections were made to the funding and acknowledgments in Optica 8, 1092 (2021)OPTIC8 2334-2536 10.1364/OPTICA.422871 .

1 October 2025 in Neurophotonics
Verified
Journal Article
Open access
KMKhuong Duy Mac
Khuong Duy Mac
SKSuhyeon Kim
Suhyeon Kim
TNTien Nhat Nguyen
Tien Nhat Nguyen
CHChristine Hwang
Christine Hwang
MKMinsung Kim
Minsung Kim
HKHYUK SANG KWON
HYUK SANG KWON
SignificanceRapid acquisition of high-resolution volumetric images has been critical to effectively monitor dynamic biological processes in vivo, yet it faces tradeoffs between image resolution, penetration depth, and imaging speed. These limitations hinder the ability to study rapid neurophysiological events such as cerebrovascular dynamics and cellular activity, highlighting the need for advanced high-speed 3D imaging system.AimTo address these challenges in volumetric imaging performances, we aimed to develop a high-speed volumetric imaging system capable of resolving fast biological dynamics with minimal compromise in spatial resolution or imaging depth.ApproachWe devised a rapid axially scanned and de-scanned (RASAD) scheme by integrating a TAG lens (tunable acoustic gradient index of refraction lens) into a line-scan confocal microscope. The TAG lens enabled axial (depth) scanning frequency at 70 kHz, allowing 3D projection imaging at rates up to 200 Hz with a detection depth of 135 μm while minimally sacrificing the image quality (i.e., a lateral resolution of ∼2.6 μm).ResultsWe validated its performance through in vitro imaging of spontaneously contracting cardiomyocyte aggregates, capturing real-time calcium transients and synchronized contractions, and through in vivo imaging of the mouse cortical tissue, where volumetric acquisition over a 450×450×100 μm3 region enabled quantification of blood flow velocities up to 3.64 mm/s across various vessel types.ConclusionsThe RASAD system enables high-speed, high-resolution 3D imaging of dynamic biological processes, providing a valuable tool for advancing studies of neurophysiological mechanisms and biomedical applications.

3 December 2021 in bioRxiv
Verified
Preprint
Open access
PDF file
KMKhuong Duy Mac
Khuong Duy Mac
MQMuhammad Mohsin Qureshi
Muhammad Mohsin Qureshi
MNMyeongsu Na
Myeongsu Na
SCSunghoe Chang
Sunghoe Chang
HKHyuk-Sang Kwon
Hyuk-Sang Kwon
ECEuiheon Chung
Euiheon Chung
In microscopic imaging of biological tissues, particularly real-time visualization of neuronal activities, rapid acquisition of volumetric images poses a prominent challenge. Typically, two-dimensional (2D) microscopy can be devised into an imaging system with 3D capability using any varifocal lens. Despite the conceptual simplicity, such an upgrade yet requires additional, complicated device components and suffers a reduced acquisition rate, which is critical to document neuronal dynamics properly. In this study, we implemented an electro-tunable lens (ETL) in the line-scan confocal microscopy, enabling the volumetric acquisition at the rate of 20 frames per second with the maximum volume of interest of 315 × 315 × 80 μm 3 . The axial extent of point-spread-function (PSF) was 17.6 ± 1.6 μm and 90.4 ± 2.1 μm with the ETL operating in either stationary or resonant mode, respectively, revealing significant depth elongation by the resonant mode ETL microscopy. We further demonstrated the utilities of the ETL system by volume imaging of cleared mouse brain ex vivo samples and in vivo brains. The current study foregrounds the successful application of resonant ETL for constructing a basis for a high-performance 3D line-scan confocal microscopy system, which will enhance our understanding of various dynamic biological processes.