Shin-Ichi Miyata

Shin-Ichi Miyata

Auto-generated profile, based on publicly available information

Shin-Ichi Miyata

SANMATSU Co., Ltd., Fukuoka, Japan

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2002 in DNA and Cell Biology
Verified
Journal Article
Closed access
SMShin-Ichi Miyata
Shin-Ichi Miyata
KFKen-Ichiro Furuki
Ken-Ichiro Furuki
KOKenro Oshima
Kenro Oshima
TSToshimi Sawayanagi
Toshimi Sawayanagi
HNHisashi Nishigawa
Hisashi Nishigawa
SNShigetou Namba
Shigetou Namba
An 11.4-kbp region of genomic DNA containing the complete S10-spc operon was constructed by an integrative mapping technique with eight plasmid vectors carrying ribosomal protein sequences from onion yellows phytoplasma. Southern hybridization analysis indicated that phytoplasmal S10-spc is a single-copy operon. This is the first complete S10-spc operon of a phytoplasma to be reported, although only a part of six serial genes of the S10 operon is reported previously. The operon has a context of 5′-rps10, rpl3, rpl4, rpl23, rpl2, rps19, rpl22, rps3, rpl16, rpl29, rps17, rpl14, rpl24, rpl5, rps14, rps8, rpl6, rpl18, rps5, rpl30, rpl15, SecY-3′, and is composed of 21 ribosomal protein subunit genes and a SecY protein translocase subunit gene. Resembling Bacillus, this operon contains an rpl30 gene that other mollicutes (Mycoplasma genitalium, M. pneumoniae, and M. pulmonis) lack. A phylogenetic tree based on the rps3 sequence showed that phytoplasmas are phylogenetically closer to acholeplasmas and bacillus than to mycoplasmas. In the S10-spc operon, translation may start from either a GTG codon or an ATG codon, and stop at a TGA codon, as has been reported for acholeplasmas and bacillus. However, in mycoplasmas, GTG was found as a start codon, and TGA was found not as a stop codon, but instead as a tryptophan codon. These data derived from the gene organization, and the genetic code deviation support the hypothesis that phytoplasmal genes resemble those of acholeplasmas and Bacillus more than those of other mollicutes.

6 February 2025 in Current Urology
Verified
Journal Article
Open access
SKSatoshi Kobayashi
Satoshi Kobayashi
RNRyu Nakadate
Ryu Nakadate
SMShinichi Miyata
Shinichi Miyata
KTKeiji Tsukino
Keiji Tsukino
JMJun Mutaguchi
Jun Mutaguchi
MEMasatoshi Eto
Masatoshi Eto
Background: We assessed the feasibility of a new probe attachment (PA) developed to improve the ease of holding the drop-in-type L43K ultrasound probe during robot-assisted partial nephrectomy. Materials and methods: We retrospectively analyzed the outcomes of 58 patients after robot-assisted partial nephrectomy using the conventional grip and 13 patients after surgery using the PA between September 2019 and February 2021. Propensity score matching (1:1) was performed to adjust for potential baseline confounders. The usability of the PA was evaluated regarding (1) total procedure time for intraoperative laparoscopic ultrasound; (2) proportion rate of intraoperative laparoscopic ultrasound in console time; (3) total number of probe fin grips; (4) total number of grip failures; (5) intraoperative laparoscopic ultrasound procedure time per grip; and (6) rate of successful gripping. Results: After matching, 12 patients were allocated to each group, and the tumor site was significantly different between the groups. Usability was significantly better in the PA group: (1) conventional versus PA: 6.8 versus 7.6, p = 0.53; (2) 5.6% versus 6.1%, p = 0.61; (3) 8 versus 10, p = 0.32; (4) 3 versus 0, p = 0.014; and (5) 1.5% versus 0.7%, p = 0.021; (6) 66% versus 100%, p = 0.002. In patients with complex renal tumors, completely endophytic tumors, and renal hilum tumors, nearly identical improvements in usability were observed: (1) 9.8 versus 7.8 min, p = 0.21; (2) 9.9% versus 4.7%, p = 0.001; (3) 7 versus 6, p = 0.025; (4) 3 versus 0, p = 0.048, (5) 2.9 versus 1.6 min, p = 0.89, and (6) 60% versus 100%, p = 0.003. Conclusions: Our proposed L43K PA can enhance the usability of the probe for intraoperative laparoscopic ultrasonography during robot-assisted partial nephrectomy and increase the accuracy of ultrasonography for complex renal tumors.