The aim of this retrospective study was to evaluate the clinical outcome of three different minimally invasive surgical techniques for left anterior descending (LAD) coronary artery bypass grafting (CABG): Port-Access surgery (PA-CABG), minimally invasive direct CABG (MIDCAB) and off-pump totally endoscopic CABG (TECAB).
Background: Left ventricular stroke area by transoesophageal echocardiographic automated border detection has been shown to be strongly correlated to left ventricular stroke volume. Respiratory variations in left ventricular stroke volume or its surrogates are good predictors of fluid responsiveness in mechanically ventilated patients. We hypothesised that respiratory variations in left ventricular stroke area (ΔSA) can predict fluid responsiveness. Methods: Eighteen mechanically ventilated patients undergoing coronary artery bypass grafting were studied immediately after induction of anaesthesia. Stroke area was measured on a beat-to-beat basis using transoesophageal echocardiographic automated border detection. Haemodynamic and echocardiographic data were measured at baseline and after volume expansion induced by a passive leg raising manoeuvre. Responders to passive leg raising manoeuvre were defined as patients presenting a more than 15% increase in cardiac output. Results: Cardiac output increased significantly in response to volume expansion induced by passive leg raising (from 2.16 ± 0.79 litres per minute to 2.78 ± 1.08 litres per minute; p < 0.01). ΔSA decreased significantly in response to volume expansion (from 17% ± 7% to 8% ± 6%; p < 0.01). ΔSA was higher in responders than in non-responders (20% ± 5% versus 10% ± 5%; p < 0.01). A cutoff ΔSA value of 16% allowed fluid responsiveness prediction with a sensitivity of 92% and a specificity of 83%. ΔSA at baseline was related to the percentage increase in cardiac output in response to volume expansion (r = 0.53, p < 0.01). Conclusion: ΔSA by transoesophageal echocardiographic automated border detection is sensitive to changes in preload, can predict fluid responsiveness, and can quantify the effects of volume expansion on cardiac output. It has potential clinical applications.
14 January 2023 in Diagnostic and Interventional Imaging
The purpose of this study was to investigate the feasibility of identifying and characterizing the three most common types of endoleaks within a thoracic aorta aneurysm model using bicolor K-edge imaging with a spectral photon-counting computing tomography (SPCCT) system in combination with a biphasic contrast agent injection. Three types of thoracic endoleaks (type 1, 2 and 3) were created in a dynamic anthropomorphic thoracic aorta phantom. Protocol consisted in an injection of an iodinated contrast material followed 80 seconds after an injection of a gadolinium-based contrast agent (GBCA). The phantom was scanned using a clinical prototype SPCCT during bicolor phase imaging consisting in an early distribution of GBCA and a late distribution of iodine. Conventional and spectral images were reconstructed for differentiating between the contrast agents and measuring their respective attenuation values and concentrations inside and outside the stent graft. Conventional images failed to provide specific dynamic imaging contrast agents in the aneurysmal sac and outside the stent graft while spectral images differentiated their specific distribution. In type 1 and 3 thoracic endoleaks, GBCA concentration was measured outside the stent graft at 6.1 ± 3.7 (standard deviation [SD]) mg/mL and 6.0 ± 4.0 (SD) mg/mL, respectively, in favor of an early blood flow. In type 2 thoracic endoleak, iodine was measured outside the stent graft at 24.3 ± 5.5 (SD) mg/mL in favor of a late blood flow in the aneurysmal sac. Bicolor K-edge imaging enabled SPCCT allows a bicolor characterization of thoracic aorta endoleaks in a single acquisition in combination with a biphasic contrast agent injection.
7 June 2017 in European Journal of Cardio-Thoracic Surgery
OBJECTIVES: Our goal was to evaluate the operative outcomes of the frozen elephant trunk technique using the E-Vita Open Plus® hybrid prosthesis in chronic aortic arch diseases and report clinical and radiological outcomes at the 1-year follow-up. METHODS: As determined from a prospective multicentre registry, 94 patients underwent frozen elephant trunk procedures using the E-Vita Open Plus hybrid device for the treatment of chronic aortic conditions, including 50% chronic aortic dissections, 40% degenerative aneurysms and 10% miscellaneous indications. Fifty percent of the cases were reoperations. RESULTS: The perioperative mortality rate was 11.7%. Spinal cord ischaemia and stroke rates were 4% and 9.6%, respectively. The mean cardiopulmonary bypass time was 252 ± 97 min, cardiac ischaemia time was 152 ± 53 min and cerebral perfusion time was 82 ± 22 min. Concomitant procedures were observed in 15% of patients. Among the 83 surviving patients, the survival rate after the 1-year follow-up was 98%. Eleven percent of patients underwent endovascular completion, whereas 4% of patients required aortic reintervention at 1 year. CONCLUSIONS: The E-Vita Open Plus hybrid device confirms the favourable short- and mid-term outcomes offered by its predecessor in frozen elephant trunk procedures in patients with chronic aortic arch disease. Implantation of the E-Vita Open Plus is associated with good 1-year survival rates, good rates of favourable aortic remodelling in both chronic dissection and degenerative aneurysms and a reproducible technique in a multicentre registry. Continued follow-up is required due to the risk of evolution at the downstream aorta.
1 January 2007 in European Journal of Cardio-Thoracic Surgery
The introduction of robotic assistance has enabled totally endoscopic closed chest procedures, most often by left internal thoracic artery to left (LITA) anterior descending. Endoscopic stabilizers have made off-pump surgery feasible. We report the first case of a totally endoscopic off-pump bilateral ITA grafting in a 58-year-old patient.