Simon J. Freethy

Simon J. Freethy

Auto-generated profile, based on publicly available information

Simon J. Freethy

UKAEA (United Kingdom Atomic Energy Authority)

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 March 2018 in Physics of Plasmas
Verified
Journal Article
Closed access
PDF file
SFS. J. Freethy
S. J. Freethy
TGT. Görler
T. Görler
ACA. J. Creely
A. J. Creely
GCG. D. Conway
G. D. Conway
SDS. S. Denk
S. S. Denk
ATAsdex Upgrade Team
Asdex Upgrade Team
Measurements of turbulent electron temperature fluctuation amplitudes, δTe⊥/Te , frequency spectra, and radial correlation lengths, Lr(Te⊥) , have been performed at ASDEX Upgrade using a newly upgraded Correlation ECE diagnostic in the range of scales k⊥<1.4 cm−1, kr<3.5 cm−1 (k⊥ρs<0.28 and krρs<0.7 ). The phase angle between turbulent temperature and density fluctuations, αnT, has also been measured by using an ECE radiometer coupled to a reflectometer along the same line of sight. These quantities are used simultaneously to constrain a set of ion-scale non-linear gyrokinetic turbulence simulations of the outer core (ρtor = 0.75) of a low density, electron heated L-mode plasma, performed using the gyrokinetic simulation code, GENE. The ion and electron temperature gradients were scanned within uncertainties. It is found that gyrokinetic simulations are able to match simultaneously the electron and ion heat flux at this radius within the experimental uncertainties. The simulations were performed based on a reference discharge for which δTe⊥/Te measurements were available, and Lr(Te⊥) and αnT were then predicted using synthetic diagnostics prior to measurements in a repeat discharge. While temperature fluctuation amplitudes are overestimated by >50% for all simulations within the sensitivity scans performed, good quantitative agreement is found for Lr(Te⊥) and αnT. A validation metric is used to quantify the level of agreement of individual simulations with experimental measurements, and the best agreement is found close to the experimental gradient values.

31 March 2017 in Plasma Physics and Controlled Fusion
Verified
Journal Article
Closed access
THT Happel
T Happel
TGT Görler
T Görler
PHP Hennequin
P Hennequin
CLC Lechte
C Lechte
MBM Bernert
M Bernert
USU Stroth
U Stroth
The importance of using a comprehensive suite of tools for the validation of a gyrokinetic code is described. This is detailed by presenting experimental wavenumber spectra which show pronounced differences, although they are measured at the same toroidal, poloidal and radial location. They are obtained via Doppler reflectometry and the differences are due to the probing beam polarization. These differences are reproduced convincingly using turbulence from a gyrokinetic simulation as input for two-dimensional full-wave simulation. It is demonstrated that the application of synthetic diagnostics is indispensable if non-trivial diagnostics are used in the experiment. Furthermore, the measurement of wavenumber spectra via Doppler reflectometry with X-mode probing beam polarization might be problematic due to nonlinear wave–plasma interactions and should be regarded with care when used for quantitative statements or the validation of gyrokinetic codes.

30 August 2024 in Nuclear Fusion
Verified
Journal Article
Open access
ETE. Tholerus
E. Tholerus
FCF.J. Casson
F.J. Casson
SMS.P. Marsden
S.P. Marsden
TWT. Wilson
T. Wilson
DBD. Brunetti
D. Brunetti
GXG. Xia
G. Xia
STEP is a spherical tokamak prototype power plant that is being designed to demonstrate net electric power. The design phase involves the exploitation of plasma models to optimise fusion performance subject to satisfying various physics and engineering constraints. A modelling workflow, including integrated core plasma modelling, MHD stability analysis, SOL and pedestal modelling, coil set and free boundary equilibrium solvers, and whole plant design, has been developed to specify the design parameters and to develop viable scenarios. The integrated core plasma model JETTO is used to develop individual flat-top operating points that satisfy imposed criteria for fusion power performance within operational constraints. Key plasma parameters such as normalised beta, Greenwald density fraction, auxiliary power and radiated power have been scanned to scope the operational space and to derive a collection of candidate non-inductive flat-top points. The assumed auxiliary heating and current drive is either from electron cyclotron (EC) systems only or a combination of EC and electron Bernstein waves. At present stages of transport modelling, there is a large uncertainty in overall confinement for relevant parameter regimes. For each of the two auxiliary heating and current drive systems scenarios, two candidate flat-top points have been developed based on different confinement assumptions, totalling to four operating points. A lower confinement assumption generally suggests operating points in high-density, high auxiliary power regimes, whereas higher confinement would allow access to a broader parameter regime in density and power while maintaining target fusion power performance.

27 March 2015 in Physical Review Letters
Verified
Journal Article
Open access
PDF file
SFS. J. Freethy
S. J. Freethy
KMK. G. McClements
K. G. McClements
SCS. C. Chapman
S. C. Chapman
RDR. O. Dendy
R. O. Dendy
WLW. N. Lai
W. N. Lai
RVR. G. L. Vann
R. G. L. Vann
Recent measurements of microwave and x-ray emission during edge localized mode (ELM) activity in tokamak plasmas provide a fresh perspective on ELM physics. It is evident that electron kinetics, which are not incorporated in standard (fluid) models for the instability that drives ELMs, play a key role in the new observations. These effects should be included in future models for ELMs and the ELM cycle. The observed radiative effects paradoxically imply acceleration of electrons parallel to the magnetic field combined with rapid acquisition of perpendicular momentum. It is shown that this paradox can be resolved by the action of the anomalous Doppler instability which enables fast collective radiative relaxation, in the perpendicular direction, of electrons accelerated in the parallel direction by inductive electric fields generated by the initial ELM instability.

19 July 2016 in Review of Scientific Instruments
Verified
Journal Article
Closed access
SFS. J. Freethy
S. J. Freethy
GCG. D. Conway
G. D. Conway
ICI. Classen
I. Classen
ACA. J. Creely
A. J. Creely
THT. Happel
T. Happel
AWA. E. White
A. E. White
Turbulent temperature fluctuations are measured on the ASDEX Upgrade tokamak using pairs of closely spaced, narrow-band heterodyne radiometer channels and a standard correlation technique. The pre-detection spacing and bandwidth of the radiometer channel pairs is chosen such that they are physically separated less than a turbulent correlation length, but do not overlap. The radiometer has 4 fixed filter frequency channels and two tunable filter channels for added flexibility in the measurement position. Relative temperature fluctuation amplitudes are observed in a helium plasma to be δT/T = (0.76 ± 0.02)%, (0.67 ± 0.02)%, and (0.59 ± 0.03)% at normalised toroidal flux radius of ρtor = 0.82, 0.75, and 0.68, respectively.

1 January 2019 in Nuclear Materials and Energy
Verified
Journal Article
Open access
THT. Happel
T. Happel
MGM. Griener
M. Griener
DSD. Silvagni
D. Silvagni
SFS.J. Freethy
S.J. Freethy
PHP. Hennequin
P. Hennequin
EVE. Viezzer
E. Viezzer