Piotr Zdańkowski

Piotr Zdańkowski

Auto-generated profile, based on publicly available information

Piotr Zdańkowski

Warsaw University of Technology

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 September 2019 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
Maciej TrusiakMaciej Trusiak
Maciej Trusiak
Jose Angel Picazo BuenoJose Angel Picazo Bueno
Jose Angel Picazo Bueno
KPKrzysztof Patorski
Krzysztof Patorski
PZPiotr Zdankowski
Piotr Zdankowski
VMVicente Mico-Serrano
Vicente Mico-Serrano
Among a suite of modern microscopy techniques, quantitative phase imaging (QPI)1 – 3 stands out as a vividly blossoming and extremely capable label-free approach. It provides a unique means for imaging cells and tissues, merging beneficial features established at the core of microscopy,1 interferometry and holography,4 and numerical computations. Using the refractive index as an intrinsic contrast agent,5 QPI numerically converts the holographically encoded complex optical field of micro-objects into a nanoscale-precise subcellular-specific 2-D/3-D/4-D map of the examined transparent specimen.6,7 Impressive details can be imaged, e.g., via superresolution approaches,8 even in live organisms, without severe photo-damage. Application-oriented QPI research provided recently outstanding solutions in numerous exciting biomedical fields, i.e., in neuroscience, methods such as digital holographic microscopy (DHM),9 spatial light interference microscopy (SLIM),10 and optical diffraction tomography (ODT);11 in cell/tissue biology, ODT,11 SLIM,10 transport of intensity,12 Fourier ptychography,13 and quadriwave interferometry;14 and in cancer diagnosis, DHM15 and diffraction phase microscopy,16,17 to name only some approaches. It is also worth showcasing the importance of in-flow quantitative phase measurements.18,19

18 June 2021 in Biomedical Optics Express
Verified
Journal Article
Closed access
PZPiotr Zdańkowski
Piotr Zdańkowski
JWJulianna Winnik
Julianna Winnik
KPKrzysztof Patorski
Krzysztof Patorski
PGPaweł Gocłowski
Paweł Gocłowski
MZMichał Ziemczonok
Michał Ziemczonok
Maciej TrusiakMaciej Trusiak
Maciej Trusiak
In this work we propose an open-top like common-path intrinsically achromatic optical diffraction tomography system. It operates as a total-shear interferometer and employs Ronchi-type amplitude diffraction grating, positioned in between the camera and the tube lens without an additional 4f system, generating three-beam interferograms with achromatic second harmonic. Such configuration makes the proposed system low cost, compact and immune to vibrations. We present the results of the measurements of 3D-printed cell phantom using laser diode (coherent) and superluminescent diode (partially coherent) light sources. Broadband light sources can be naturally employed without the need for any cumbersome compensation because of the intrinsic achromaticity of the interferometric recording (holograms generated by –1st and +1st conjugated diffraction orders are not affected by the illumination wavelength). The results show that the decreased coherence offers much reduced coherent noise and higher fidelity tomographic reconstruction especially when applied nonnegativity constraint regularization procedure.

25 March 2019 in Biomedical Optics Express
Verified
Journal Article
Closed access
PDF file
PZPiotr Zdankowski
Piotr Zdankowski
DMDavid McGloin
David McGloin
JSJason R. Swedlow
Jason R. Swedlow
Stimulated emission depletion (STED) nanoscopy is one of a suite of modern optical microscopy techniques capable of bypassing the conventional diffraction limit in fluorescent imaging. STED makes use of a spiral phase mask to enable 2D super-resolution imaging whereas to achieve full volumetric 3D super-resolution an additional bottle-beam phase mask must be applied. The resolution achieved in biological samples 10 µm or thicker is limited by aberrations induced mainly by scattering due to refractive index heterogeneity in the sample. These aberrations impact the fidelity of both types of phase mask, and have limited the application of STED to thicker biological systems. Here we apply an automated adaptive optics solution to correct the performance of both STED masks, enhancing robustness and expanding the capabilities of this nanoscopic technique. Corroboration in terms of successful high-quality imaging of the full volume of a 15µm mitotic spindle with resolution of 50nm x 50nm x 150nm achieved in all three dimensions is presented.

24 February 2020 in Optics Express
Verified
Journal Article
Closed access
KPKrzysztof Patorski
Krzysztof Patorski
PZPiotr Zdańkowski
Piotr Zdańkowski
Maciej TrusiakMaciej Trusiak
Maciej Trusiak
Interference microscopy is a powerful optical imaging technique providing quantitative phase distribution information to characterize various type technical and biomedical objects. Static and dynamic objects and processes can be investigated. In this paper we propose very compact, common-path and partially coherent diffraction grating-based interference microscopy system for studying small objects like single cells with low densities being sparsely distributed in the field of view. Simple binary amplitude diffraction grating is the only additional element to be introduced into a conventional microscope optical system. By placing it at a proper distance in front of the microscope image plane the total-shear operation mode is deployed resulting in interferograms of the object-reference beam type. Depending on the grating to image plane separation distance two or three-beam interferograms are generated. The latter ones are advantageous since they contain achromatic second harmonics in the interferogram intensity distributions. This feature enables to use reduced temporal coherence light sources for the microscope to reduce coherent noise and parasitic interference patterns. For this purpose we employ the laser diode with driving current below the threshold one. Results of conducted experiments including automatic computer processing of interferograms fully corroborate analytical description of the proposed method and illustrate its capabilities for studying static and dynamic phase objects.

16 December 2019 in ACS Nano
Verified
Journal Article
Closed access
PZPiotr Zdańkowski
Piotr Zdańkowski
MTMaciej Trusiak
Maciej Trusiak
DMDavid McGloin
David McGloin
JSJason R. Swedlow
Jason R. Swedlow

8 April 2021 in Bioinformatics
Verified
Journal Article
Closed access
PDF file
MRMikołaj Rogalski
Mikołaj Rogalski
PZPiotr Zdańkowski
Piotr Zdańkowski
MTMaciej Trusiak
Maciej Trusiak
Fourier ptychographic microscopy (FPM) is a computational microscopy technique that enables large field of view and high-resolution microscopic imaging of biological samples. However, the FPM does not yet have an adequately capable open-source software. In order to fill this gap we are presenting novel, simple, universal, semi-automatic and highly intuitive graphical user interface (GUI) open-source application called the FPM app enabling wide-scale robust FPM reconstruction. Apart from implementing the FPM in accessible GUI app, we also made several improvements in the FPM image reconstruction process itself, making the FPM more automatic, noise-robust and faster. FPM app was implemented in MATLAB and all MATLAB codes along with standalone executable version of the FPM app and the online documentation are freely accessible at https://github.com/MRogalski96/FPM-app. Our exemplary FPM datasets may be downloaded at https://bit.ly/2MxNpGb. Supplementary data are available at Bioinformatics online.