Jeroen Johannes Briaire

Jeroen Johannes Briaire

Auto-generated profile, based on publicly available information

Jeroen Johannes Briaire

Department of Otorhinolaryngology and Head & Neck Surgery, Leiden University Medical Center

Research Focus & Metrics

Academic Career Length

26Years (2001-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2005 in Hearing Research
Verified
Journal Article
Closed access
JBJeroen J. Briaire
Jeroen J. Briaire
JFJohan HM Frijns
Johan HM Frijns

1 April 2015 in Hearing Research
Verified
Journal Article
Closed access
RKRandy K. Kalkman
Randy K. Kalkman
JBJeroen J. Briaire
Jeroen J. Briaire
JFJohan HM Frijns
Johan HM Frijns

8 April 2021 in Ear & Hearing
Verified
Journal Article
Open access
YDYu Dong
Yu Dong
JBJeroen J. Briaire
Jeroen J. Briaire
MSMichael Siebrecht
Michael Siebrecht
HSH. Christiaan Stronks
H. Christiaan Stronks
JFJohan HM Frijns
Johan HM Frijns
Objectives: Misplacement of the electrode array is associated with impaired speech perception in patients with cochlear implants (CIs). Translocation of the electrode array is the most common misplacement. When a CI is translocated, it crosses the basilar membrane from the scala tympani into the scala vestibuli. The position of the implant can be determined on a postoperative CT scan. However, such a scan is not obtained routinely after CI insertion in many hospitals, due to radiation exposure and processing time. Previous studies have shown that impedance measures might provide information on the placement of the electrode arrays. The electrode impedance was measured by dividing the plateau voltage at the end of the first phase of the pulse by the injected current. The access resistance was calculated using the so-called access voltage at the first sampled time point after the start of the pulse divided by the injected current. In our study, we obtained the electrode impedance and the access resistance to detect electrode translocations using electrical field imaging. We have investigated how reliably these two measurements can detect electrode translocation, and which method performed best. Design: We calculated the electrode impedances and access resistances using electrical field imaging recordings from 100 HiFocus Mid-Scala CI (Advanced Bionics, Sylmar, CA) recipients. We estimated the normal values of these two measurements as the baselines of the implant placed in the cochlea without translocation. Next, we calculated the maximal electrode impedance deviation and the maximal access-resistance deviation from the respective baselines as predictors of translocation. We classified these two predictors as translocations or nontranslocations based on the bootstrap sampling method and receiver operating characteristics curves analysis. The accuracy could be calculated by comparing those predictive results to a gold standard, namely the clinical CT scans. To determine which measurement more accurately detected translocation, the difference between the accuracies of the two measurements was calculated. Results: Using the bootstrap sampling method and receiver operating characteristics–based optimized threshold criteria, the 95% confidence intervals of the accuracies of translocation detections ranged from 77.8% to 82.1% and from 89.5% to 91.2% for the electrode impedance and access resistance, respectively. The accuracies of the maximal access-resistance deviations were significantly larger than that of the maximal electrode impedance deviations. The location of the translocation as predicted by the access resistance was significantly correlated with the result derived from the CT scans. In contrast, no significant correlation was observed for the electrode impedance. Conclusions: Both the electrode impedance and access resistance proved reliable metrics to detect translocations for HiFocus Mid-Scala electrode arrays. The access resistance had, however, significantly better accuracy and it also reliably detected the electrode-location of translocations. The electrode impedance did not correlate significantly with the location of translocation. Measuring the access resistance is, therefore, the recommended method to detect electrode-array translocations. These measures can provide prompt feedback for surgeons after insertion, improving their surgical skills, and ultimately reducing the number of translocations. In the future, such measurements may allow near-real-time monitoring of the electrode array during insertion, helping to avoid translocations.

24 January 2011 in Acta Oto-Laryngologica
Verified
Journal Article
Closed access
PDF file
JFJohan HM Frijns
Johan HM Frijns
DDDavid M.T. Dekker
David M.T. Dekker
JBJeroen J. Briaire
Jeroen J. Briaire
Conclusions: Phased-array stimulation is a promising technique, which uses electrical interaction to focus the stimulation in cochlear implants, at the expense of limited threshold shifts. It has potential advantages over, for example, tripolar stimulation. Objectives: Current spread imposes limitations in cochlear implants. Van Compernolle (1985) suggested using all electrode contacts simultaneously to reduce these effects. Van den Honert et al. (2007) validated this so-called phased array algorithm in patients with respect to the electrode potentials but the effect on neural excitation remained unclear. The present study used computational modeling to relate the effect of phased-array stimulation to the neural elements. Methods: A computational model of the implanted human cochlea was used to compare the neural excitation patterns induced by conventional monopolar stimulation and by phased-array stimulation. Neural thresholds and electrical dynamic ranges were visualized with excitation profiles, showing the auditory nerve's response to a range of stimulus levels. Results: Phased-array stimulation of a single region reduces the spread of excitation and increases the dynamic range. The phased array paradigm can be extended to stimulate multiple sites simultaneously, thereby eliminating the need for sequential stimulation, but with a more limited range of usable stimulus levels, especially with perimodiolar electrodes.

1 September 2018 in Ear & Hearing
Verified
Journal Article
Closed access
JSJorien Snel-Bongers
Jorien Snel-Bongers
ANAnouk P. Netten
Anouk P. Netten
PBPeter-Paul B. M. Boermans
Peter-Paul B. M. Boermans
LRLiselotte J. C. Rotteveel
Liselotte J. C. Rotteveel
JBJeroen J. Briaire
Jeroen J. Briaire
JFJohan HM Frijns
Johan HM Frijns
Objectives: This study determined the relationship between preoperative phoneme and word scores and the gain in speech perception after cochlear implantation in a large cohort of patients. The authors aimed to define evidence-based selection criteria for cochlear implantations in adults with postlingual deafness. Design: This retrospective study included 364 adults with postlingual deafness who received a cochlear implant between 2000 and 2013 at the Leiden University Medical Center. The gain in speech perception observed postimplantation was compared with preoperative-aided/binaural speech perception scores, measured at 65 dB SPL in quiet. Patients who showed preoperative phoneme scores on monosyllabic words above 50% were also tested for speech perception in the presence of speech-shaped background noise, at a +5 dB signal to noise ratio. Results: Speech perception in quiet improved after implantation in all except 7 patients. Average scores in quiet continued to improve, up to approximately 1 year after implantation. When participants were divided into five groups, based on preoperative speech perception scores, all groups showed gains in speech perception, except for the group with aided preoperative phoneme scores above 80%. However, all patients who were tested preoperatively with the addition of background noise showed improvements in speech perception in noise after the cochlear implantation. Conclusions: Although the decision to implant should consider individual ear differences and other factors that might apply to a particular case, based on our data, all patients with preoperative scores of either 80% (phonemes correct) or 60% (words correct) and lower in an optimal-aided situation are potential candidates for a cochlear implant, provided that their preoperative speech perception score decreases below 50% (phonemes correct) or 20% (words correct), when background noise is added at a +5 dB signal to noise ratio.

22 May 2013 in Journal of the Association for Research in Otolaryngology
Verified
Journal Article
Closed access
PDF file
JSJorien Snel-Bongers
Jorien Snel-Bongers
JBJeroen J. Briaire
Jeroen J. Briaire
EVErika H. van der Veen
Erika H. van der Veen
RKRandy K. Kalkman
Randy K. Kalkman
JFJohan HM Frijns
Johan HM Frijns