S. G. Abbasova

S. G. Abbasova

Auto-generated profile, based on publicly available information

S. G. Abbasova

International Biotechnology Center “Generium

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 October 2021 in Biological Products. Prevention, Diagnosis, Treatment
Verified
Journal Article
Open access
PDF file
DPDmitry Poteryaev
Dmitry Poteryaev
SAS. G. Abbasova
S. G. Abbasova
PIP. E. Ignatyeva
P. E. Ignatyeva
OSOlga Strizhakova
Olga Strizhakova
SKS. V. Kolesnik
S. V. Kolesnik
RKRavil Khamitov
Ravil Khamitov
With the onset of the COVID-19 pandemic, a number of molecular-based tests have been developed to diagnose SARS-CoV-2 infection. However, numerous available serological tests lack sufficient sensitivity or specificity. They do not detect specific antibodies in a significant proportion of patients with PCR-confirmed COVID-19. There is evidence that some convalescents have a relatively short-lived humoral immunity. In contrast, a number of publications have shown that T-cell response to human coronaviruses, including SARS-CoV-1, MERS, and SARS-CoV-2, can be strong and long-term. Assessment of T-cell immunity to SARS-CoV-2 is important not only for stratification of risks and identification of potentially protected populations with immunity acquired as a result of previous infection, but also for determining immunogenicity and potential efficacy of vaccines under development. The existing methods of quantitative or semi-quantitative assessment of specific T-cell response are mainly used in scientific research and are not standardised. The aim of the study was to develop and verify experimentally a test kit to be used in a standardised procedure for in vitro determination of T-cells specific to SARS-CoV-2 antigens, in human peripheral blood. Materials and methods: the TigraTest® SARS-CoV-2 kit developed by GENERIUM, which determines the number of T-cells secreting interferon gamma in vitro, was tested in the study. Samples of venous blood of volunteers from three different groups were analysed in the study: presumably healthy volunteers; COVID-19 convalescents; individuals vaccinated against SARS-CoV-2. Results: the authors developed the TigraTest® SARS-CoV-2 kit for in vitro determination of T-cells specific to SARS-CoV-2 antigens in human peripheral blood, demonstrated its specificity and performed preliminary assessment of its sensitivity. The study analysed the range and magnitude of the T-cell response in convalescent and vaccinated individuals. A pronounced T-cell response was also shown in some individuals with no symptoms or with unconfirmed diagnosis. It was discovered that the mean T-cell response to peptides of the spike protein (S-protein) was higher in the vaccinated individuals than in the convalescent patients. A correlation was determined between the severity of the disease and the level of T-cell response. Specific contributions of various groups of antigens to the T-cell response after COVID-19 infection were also determined. Conclusions: the TigraTest® SARS-CoV-2 kit is a specific and sensitive tool for the assessment of T-cell immunity to the SARS-CoV-2 virus, which can also be used for vaccinated individuals. The kit may be used in clinical practice for comprehensive assessment of immunity to SARS-CoV-2.

19 June 2024 in Regulatory Research and Medicine Evaluation
Verified
Journal Article
Closed access
YNYu. A. Nikonova
Yu. A. Nikonova
SAS. G. Abbasova
S. G. Abbasova
PKP. E. Kargopolova
P. E. Kargopolova
OSOlga Strizhakova
Olga Strizhakova
ILIvan Lyagoskin
Ivan Lyagoskin
Andrei Sergeevitch PershinAndrei Sergeevitch Pershin
Andrei Sergeevitch Pershin
INTRODUCTION. Bioanalytical techniques are characterised by greater variability and lower stability than physicochemical methods because live test systems are inherently labile. Since regulatory standards do not establish a unified approach, the selection of system suitability criteria and acceptance criteria for test results is based on validation studies.AIM. This study aimed to validate an analytical procedure for evaluating the biological activity of a medicinal product based on the investigational tocilizumab biosimilar GNR-087 and determine the quantitative limits for system suitability criteria and acceptance criteria for test results.MATERIALS AND METHODS. The biological activity of the investigational tocilizumab biosimilar was assessed by the inhibition of IL-6-induced secreted embryonic alkaline phosphatase (SEAP) expression by HEK-Blue™ IL-6 cells. Statistical processing of the obtained results was performed using Prism 6.0 software.RESULTS. The specificity of the analytical procedure was confirmed by the dose-dependent inhibition of IL-6-induced SEAP expression by cells observed with tocilizumab. The analytical procedure was linear, with a coefficient of determination R2≥ 0.99. The precision of the analytical procedure was satisfactory; its repeat ability varied from 2 to 9%, and its intermediate precision was 14%. The recovery coefficients (Rc) for spiked samples simulating activity levels of 60–140%, including blinded samples, ranged from 80 to 120%. The theoretical values of relative potency (RP) were within the confidence intervals of the mean relative potency estimates, which confirmed the accuracy of the analytical procedure. The validation confirmed the robustness of the analytical procedure to controlled variations, including the use of reporter cells at different passages (with a coefficient of variation for relative potency estimates (CVRP) of 10%), different IL-6 lots (with a CVRP of 1%), and different SEAP detection reagent lots (with a CVRP of 3%); the Rc remained in the range of 80–120% of the nominal RP value.CONCLUSIONS. The analytical procedure for evaluating the biological activity of the investigational tocilizumab biosimilar meets the validation criteria, including accuracy, linearity, precision, specificity, and robustness. The study established system suitability criteria and acceptable limits for biological assay results. This analytical procedure can be used both for routine biological activity control and for demonstrating the biosimilarity of new medicinal products to the original (reference) tocilizumab-based medicinal product.

25 March 2020 in Biological Products. Prevention, Diagnosis, Treatment
Verified
Journal Article
Open access
ILIvan Lyagoskin
Ivan Lyagoskin
MPM. S. Pantyushenko
M. S. Pantyushenko
OSOlga Strizhakova
Olga Strizhakova
NKN. K. Kudina
N. K. Kudina
EPE. Yu. Prudnikova
E. Yu. Prudnikova
SAS. G. Abbasova
S. G. Abbasova
Enzyme replacement therapy (ERT) is one of the most efficient treatments for lysosomal storage diseases. Type 1 Gaucher disease is caused by β-glucocerebrosidase enzyme deficiency, which may be compensated for by intravenous infusions of imiglucerase—a recombinant enzyme. Imiglucerase targets macrophages and enters these cells via interaction with mannose receptors on the cell membrane. Characterisation of internalization of enzymes by target cells is important in the context of the development of new medicines and production of existing ERT medicines. The peritoneal and alveolar macrophages, as well as macrophages of the spleen of small laboratory animals (rats and mice) are widely used in such studies. However, isolation of cells from animal sources raises ethical issues, and therefore continuous mammalian cell lines may offer an attractive alternative.The aim of thestudy:to conduct comparative studies on the internalization of recombinant imiglucerase into mouse peritoneal macrophages and L929 mouse fibroblasts.Materials and methods:CerezymeR batches 7HV0913, C6214H05, 7HV0888 (Genzyme Ltd., UK); Glurazim batches 020416, 011117, 021117 (LLC “IBC “Generium”, Russia). We used peritoneal macrophages obtained from BALB/c mice and L929 mouse fibroblasts. The cells were cultured in DMEM/F12 complete growth medium with 10% fetal bovine serum. The activity of imiglucerase internalized into the cells was evaluated spectrophotometrically by hydrolysis of the artificial substrate—4-methylumbelliferyl-β-Dglucopyranoside.Results:the study compared internalization of recombinant imiglucerase (the active ingredient of CerezymeR and Glurazim) by mouse peritoneal macrophages and L929 mouse fibroblasts. It was demonstrated that the medicines activity in the lysates of peritoneal macrophages is comparable with that in the lysates of L929 mouse fibroblasts. Regardless of the model system, the activity of Glurazim stayed within the acceptable range (80–125%) established for biosimilar products.Conclusions:the experiments proved that L929 mouse fibroblasts could be recommended for assessment of internalization of recombinant imiglucerase.