Jinwoo Seo

Jinwoo Seo

Auto-generated profile, based on publicly available information

Jinwoo Seo

Samsung Electronics, Suwon, Republic of Korea

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 July 2022 in Sleep Health
Verified
Journal Article
Open access
HJHyunjun Jung
Hyunjun Jung
DKDongyeop Kim
Dongyeop Kim
WLWonkyu Lee
Wonkyu Lee
HSHyejung Seo
Hyejung Seo
JSJinwoo Seo
Jinwoo Seo
EJEun Yeon Joo
Eun Yeon Joo
To characterize and evaluate the estimation of oxygen saturation measured by a wrist-worn reflectance pulse oximeter during sleep. Ninety-seven adults with sleep disturbances were enrolled. Oxygen saturation was simultaneously measured using a reflectance pulse oximeter (Galaxy Watch 4 [GW4], Samsung, South Korea) and a transmittance pulse oximeter (polysomnography) as a reference. The performance of the device was evaluated using the root mean squared error (RMSE) and coverage rate. Additionally, GW4-derived oxygen desaturation index (ODI) was compared with the apnea-hypopnea index (AHI) derived from polysomnography. The GW4 had an overall RMSE of 2.3% and negligible bias of -0.2%. A Bland-Altman density plot showed good agreement between the GW4 and the reference pulse oximeter. RMSEs were 1.65 ± 0.57%, 1.76 ± 0.65%, 1.93 ± 0.54%, and 2.93 ± 1.71% for normal (n = 18), mild (n = 21), moderate (n = 23), and severe obstructive sleep apnea (n = 35), respectively. The data rejection rate was 26.5%, which was caused by fluctuations in contact pressure and the discarding of data less than 70% of saturation. A GW4-ODI ≥5/h had the highest ability to predict AHI ≥15/h with sensitivity, specificity, accuracy, and area under the curve of 89.7%, 64.1%, 79.4%, and 0.908, respectively. This study evaluated the estimation of oxygen saturation by the GW4 during sleep. This device complies with both Food and Drug Administration and International Organization for Standardization standards. Further improvements in the algorithms of wearable devices are required to obtain more accurate and reliable information about oxygen saturation measurements.

13 December 2021 in JMIR Preprints
Verified
Preprint
Open access
HJHyunjun Jung
Hyunjun Jung
DKDongyeop Kim
Dongyeop Kim
WLWonkyu Lee
Wonkyu Lee
HSHyejung Seo
Hyejung Seo
JSJinwoo Seo
Jinwoo Seo
EJEun Yeon Joo
Eun Yeon Joo
BACKGROUND Obstructive sleep apnea (OSA) is a common sleep disorder characterized by repetitive upper airway obstruction during sleep, thereby resulting in oxygen desaturation, frequent arousals, and increased sympathetic activity. Wearable devices that measure peripheral oxygen saturation have been developed for the screening of OSA. OBJECTIVE This study aimed to validate and characterize the estimation function of oxygen saturation measured by wrist-worn reflectance pulse oximetry during sleep and to predict the derived OSA using the oxygen desaturation index (ODI). METHODS Oxygen saturation was simultaneously measured using reflectance pulse oximetry from the Samsung Galaxy Watch 4 series (SM-R890N, SM-R860N, Samsung Electronics Co.; GW4) and transmittance pulse oximetry from polysomnography as a reference (SpO2Ref). The performance was evaluated by the root mean squared error (RMSE) and coverage rate, and it was compared according to the apnea-hypopnea index (AHI). The GW4-ODI was used to predict moderate to severe OSA. RESULTS A total of 97 adults (44.4 ± 13.0 years; men 76.3%, women 23.7%) participated in this study. Depending on the AHI, participants were classified as either normal (n=18), mild (n=21), moderate (n=23), or severe OSA (n=35). Wrist-worn reflectance pulse oximetry showed an overall RMSE of 2.3% and negligible bias of -0.2%. A Bland-Altman density plot showed good agreement of oxygen saturation between GW4 and the reference pulse oximeter. RMSEs were 1.65 ± 0.57%, 1.76 ± 0.65%, 1.93 ± 0.54%, and 2.93 ± 1.71% for normal, mild, moderate, and severe OSA, respectively. GW4-ODI ≥5/h had the highest predictive ability for moderate to severe OSA with a sensitivity of 89.7%, a specificity of 64.1%, an accuracy of 79.4%, and an area under the curve of 0.908 (95% CI, 0.852–0.963). CONCLUSIONS GW4 was successfully validated for measuring oxygen saturation with reflectance pulse oximetry during sleep. This study demonstrates the feasibility of GW4 for screening moderate to severe OSA.