Pedro Lima Emmerich Oliveira

Pedro Lima Emmerich Oliveira

Auto-generated profile, based on publicly available information

Pedro Lima Emmerich Oliveira

Orthodontics and Paediatric Dentistry Department, Federal University of Rio de Janeiro, Brazil

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 January 2022 in Materials
Verified
Journal Article
Open access
PDF file
ESEricles Otávio Santos
Ericles Otávio Santos
POPedro Lima Emmerich Oliveira
Pedro Lima Emmerich Oliveira
TMThaís Mello
Thaís Mello
André Luis SantosAndré Luis Santos
André Luis Santos
CECarlos Nelson Elias
Carlos Nelson Elias
ACAmanda Cunha Regal de Castro
Amanda Cunha Regal de Castro
The wide application of additive manufacturing in dentistry implies the further investigation into oral micro-organism adhesion and biofilm formation on vat-photopolymerization (VP) dental resins. The surface characteristics and microbiological analysis of a VP dental resin, printed at resolutions of 50 μm (EG-50) and 100 μm (EG-100), were evaluated against an auto-polymerizing acrylic resin (CG). Samples were evaluated using a scanning electron microscope, a scanning white-light interferometer, and analyzed for Candida albicans (CA) and Streptococcus mutans (SM) biofilm, as well as antifungal and antimicrobial activity. EG-50 and EG-100 exhibited more irregular surfaces and statistically higher mean (Ra) and root-mean-square (rms) roughness (EG-50-Ra: 2.96 ± 0.32 µm; rms: 4.05 ± 0.43 µm/EG-100-Ra: 3.76 ± 0.58 µm; rms: 4.79 ± 0.74 µm) compared to the CG (Ra: 0.52 ± 0.36 µm; rms: 0.84 ± 0.54 µm) (p < 0.05). The biomass and extracellular matrix production by CA and SM and the metabolic activity of SM were significantly decreased in EG-50 and EG-100 compared to CG (p < 0.05). CA and SM growth was inhibited by the pure unpolymerized VP resin (48 h). EG-50 and EG-100 recorded a greater irregularity, higher surface roughness, and decreased CA and SM biofilm formation over the CG.

6 October 2022 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
WCWagner Coimbra
Wagner Coimbra
POPedro Oliveira
Pedro Oliveira
Carlos MarquesCarlos Marques
Carlos Marques
Arnaldo Leal-JuniorArnaldo Leal-Junior
Arnaldo Leal-Junior
Fiber Bragg Grating (FBG) sensors are strain and temperature sensors with advantages such as small diameter, multiplexing capability, intrinsic safety and biocompatibility. In dentistry, FBG sensors were tested in appliances, implants and splints. In addition to the study of dental biomechanics, these sensors are used in the development of new techniques and products or in the comparison of established treatments. The working principle of measurement of bite forces applied to occlusal splints and the distributed sensing capability along the Chirped FBG (CFBG) are demonstrated in the present proof-of-concept using a PDMS silicone splint. The CFBG exhibits different spectral shapes for each of the four positions of the one-point force application. The average wavelength and the full width at half maximum (FWHM) of the spectra reflected by the CFBG are able to estimate the intensities and the positions, respectively, of the compression forces of the tooth. The instrumentation of occlusal splints with CFBG sensors can help in the distinction between different bite patterns in occlusal stabilization splints during bruxism episodes, along with the understanding of the effects and efficacy of these appliances in treatments and the comparison of different 3D-printed and traditional occlusal splints.

1 January 2021 in Dental Press Journal of Orthodontics
Verified
Journal Article
Open access
POPedro Lima Emmerich Oliveira
Pedro Lima Emmerich Oliveira
KSKayque Euclides Moreira Soares
Kayque Euclides Moreira Soares
RARafhael Milanezi de Andrade
Rafhael Milanezi de Andrade
GOGabriel Couto de Oliveira
Gabriel Couto de Oliveira
MPMatheus Melo Pithon
Matheus Melo Pithon
ESEduardo Franzotti Sant’anna
Eduardo Franzotti Sant’anna
Objective: In this study, simulations were performed by the finite element method (FEM) to determine the tension and displacement in mini-implants and in expander appliance during rapid maxillary expansion, by varying the number and location of the mini-implants. Methods: For the computational simulation, a three-dimensional mesh was used for the maxilla, mini-implants and expander appliance. Comparisons were made on six different Mini-implant Assisted Rapid Palatal Expander (MARPE) configurations, by varying the amount and location of mini-implants. A closed suture was design and received two activations of 0.25 mm, and an open suture had a 0.5-mm aperture that received 20 activations, also of 0.25 mm. Results: For the closed suture, the maximum displacement values in the mini-implants were between 0.253 and 0.280 mm, and stress was between 1,348.9 and 2,948.2 MPa; in the expander appliance, the displacement values were between 0.256 and 0.281 mm, and stress was between 738.52 and 1,207.6 MPa. For the open suture, the maximum displacement values in the mini-implants were between 2.57 and 2.79 mm, and stress was between 5,765.3 and 10,366 MPa; in the appliance, the maximum displacements was between 2.53 and 2.89 mm, and stress was between 4,859.7 and 9,157.4 MPa. Conclusions: There were higher stress concentrations in the mini-implant than in the expander arm. In the simulations with a configuration of three mini-implants, stress overload was observed in the isolated mini-implant. Displacements of the mini-implants and arms of the appliance were similar in all simulations.

1 April 2015 in Dental Press Journal of Orthodontics
Verified
Journal Article
Open access
PDF file
POPedro Lima Emmerich Oliveira
Pedro Lima Emmerich Oliveira
AMAndrea Fonseca Jardim da Motta
Andrea Fonseca Jardim da Motta
CGClarice Julia Guerra
Clarice Julia Guerra
JMJosé Nelson Mucha
José Nelson Mucha
OBJECTIVE: To compare the visual analogue scale (VAS) and the simplified Q-sort method used to investigate the highest level of agreement among dentists, orthodontists and laypeople when assessing smile and dental attractiveness. MATERIAL AND METHODS: An album containing 258 photos of 86 individuals with their lips at rest, a slight and broad smile, was assessed by 25 dentists (general clinicians and various specialties), 23 orthodontists and 27 laypeople with regard to smile and dental attractiveness. To this end, both VAS and simplified Q-sort method were used. Agreements were calculated by intraclass correlation coefficient (ICC). RESULTS: For the single measurement between the VAS method and the simplified Q-sort method, all simplified Q-sort rates were higher in all groups. The simplified Q-sort method results ranged between 0.42 and 0.49 while those of the VAS method varied between 0.37 and 0.42. The simplified Q-sort method also presented higher mean measurement values (0.95 and 0.96) in comparison to VAS (0.94 and 0.95). CONCLUSIONS: Both scales may be considered reliable for evaluating smile and dental attractiveness; however, the simplified Q-Sort method presented slightly higher values than the VAS method.

4 December 2020 in Orthodontics & Craniofacial Research
Verified
Journal Article
Closed access
PDF file
POPedro Lima Emmerich Oliveira
Pedro Lima Emmerich Oliveira
VCVinicius Campos
Vinicius Campos
RARafhael Milanezi de Andrade
Rafhael Milanezi de Andrade
MAMônica Tirre de Souza Araújo
Mônica Tirre de Souza Araújo
MPMatheus Melo Pithon
Matheus Melo Pithon
ESEduardo Franzotti Sant'ANna
Eduardo Franzotti Sant'ANna

1 January 2017 in Australasian Orthodontic Journal
Verified
Journal Article
Open access
PDF file
POPedro Lima Emmerich Oliveira
Pedro Lima Emmerich Oliveira
MMMírian Aiko Nakane Matsumoto
Mírian Aiko Nakane Matsumoto
GFGisele Faria
Gisele Faria
FRFábio Lourenço Romano
Fábio Lourenço Romano
Background: Intermaxillary elastics are widely used in corrective orthodontic treatment particularly for the interdigitation of buccal segments and the correction of the midline. However, latex has been known to cause allergy, which may restrict elastic use. As alternative materials, non-latex elastics are available. However, clinicians must be aware of their mechanical properties, especially those of deformation and force degradation that affect these materials over time. Objectives: The aim of this study was to compare force degradation and deformation of 3 / 16 ” non-latex and latex elastics supplied by several manufacturers. Materials and methods: Special acrylic plates were fabricated to incorporate orthodontic brackets to which elastics were attached and stretched to a distance of approximately 20 mm. The internal diameter and force magnitude of each elastic was measured at time intervals of 0, 24, 72 and 504 hours. The samples were stored in artificial saliva at room temperature during the entire experimental period. Results: Latex elastics showed smaller and more uniform deformation than the non-latex elastics. The non-latex elastics showed greater degradation at all time intervals ( p < 0.001). The Morelli brand delivered greater force than other brands for both the latex and non-latex elastics at all time intervals ( p < 0.05). The G&H latex elastics showed greater force degradation in comparison with the other brands ( p < 0.05). The evaluation of the Dentaurum and Orthopli non-latex elastics showed greater degradation ( p < 0.05). Conclusions: The non-latex elastics showed greater force degradation than the latex elastics. Of the latex elastics, G&H showed greater force degradation, and for the non-latex elastics, those made by Dentaurum and Orthopli degraded most.