Piraya Tantisaranon

Piraya Tantisaranon

Auto-generated profile, based on publicly available information

Piraya Tantisaranon

Emergency Laboratory Medicine and Hormones, Department of Pathology, Faculty of Medicine, Prince of Songkla University , Hat Yai , Songkhla , Thailand

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2021 in Practical Laboratory Medicine
Verified
Journal Article
Open access
PTPiraya Tantisaranon
Piraya Tantisaranon
KDKanyarat Dumkengkhachornwong
Kanyarat Dumkengkhachornwong
PAPeechana Aiadsakun
Peechana Aiadsakun
Areerat HnoonualAreerat Hnoonual
Areerat Hnoonual
Microscopic examination is essential in urine analysis. This is a simple way to collect informative data but it is also labor-intensive, time-consuming, and requires experienced staff for accurate results and interpretation. Several automated urine analyzers have been introduced for urine analysis in medical laboratories. The aim of this study was to assess and compare the performance of the most common three automated urine analyzers, Cobas 6500, UN3000-111b and iRICELL 3000. and Methods: A total of 100 routine urine samples were used in the study. Results from the three machines were compared with the routine procedure results including physical, chemical and sediment analysis. There was good correlation of urine physical and chemical analyses between the three analyzers with an overall concordance level of more than 80%. For sediment analysis, the degree of concordance between manual analysis and the three instruments was very good to good for white blood cells, red blood cells and epithelial cells, and moderate for bacteria. There were fair to good agreements between manual microscopy and the three instruments, Cobas 6500, UN3000-111b and iRICELL 3000, for casts (Cohen’s kappa 0.42, 0.38 and 0.62, respectively). The three automated urine analyzers showed similar performances and good correlation with manual microscopy. The results of this study indicate that automated urine analyzers could be used for initial urine testing to reduce high workloads and to save time, but manual microscopic analysis by experienced staff is still necessary to classify urine sediments for confirmation, especially in pathologic specimens.

19 June 2023 in Turkish Journal of Biochemistry
Verified
Journal Article
Open access
PDF file
PTPiraya Tantisaranon
Piraya Tantisaranon
KDKanyarat Dumkengkhachornwong
Kanyarat Dumkengkhachornwong
Areerat HnoonualAreerat Hnoonual
Areerat Hnoonual
Objectives: Centrifugation is a time-consuming step which increases the turnaround time (TAT) in laboratories. A few studies have addressed the effect of altering centrifugation settings on analytical quality for clinical chemistry analytes, and most of these studies have used collection tubes with gel separators. However, gel separator tubes may be unsuitable for some laboratories because they are slightly more expensive than tubes without gel separators and are not appropriate for some special tests. The aim of this study was to investigate the effect of centrifugation conditions on clinical chemistry analytes. Methods: We compared centrifugation times of 7 min at 2,200× g and 5 min at 2,750× g with the manufacturer’s protocol of 10 min at 1,300× g as the reference condition. Twenty general chemistry analytes were studied in lithium heparin plasma tubes without gel separators. Results: For all analytes except carbon dioxide (CO 2 ), no significant differences in analyte results were observed when the centrifugation time was reduced. Deming regression and Bland–Altman plots demonstrated an acceptable clinical concordance within the limits of total allowable error for all analytes between the two rapid centrifugation conditions with the reference centrifugation condition. Conclusions: Our results confirmed that alternate centrifugation conditions for either 7 min at 2,200× g or 5 min at 2,750× g of samples collected in lithium heparin tubes without gel are acceptable for clinical chemistry analytes. Our data support using centrifugation at higher speeds for shorter times to improve TAT without altering the quality of the analytical results.

16 November 2026 in Journal of Clinical Pathology
Verified
Journal Article
Closed access
PTPiraya Tantisaranon
Piraya Tantisaranon
KRKittima Rakkhitphinitdun
Kittima Rakkhitphinitdun
AJAlwanee Jeeheng
Alwanee Jeeheng
KDKanyarat Dumkengkhachornwong
Kanyarat Dumkengkhachornwong
WSWilaiwan Sriwimol
Wilaiwan Sriwimol
SSSupamai Soonthornpun
Supamai Soonthornpun