Image reconstruction in fluorescence microscopy is highly sensitive to the accuracy of the impulse response, defined as the point spread function (PSF), of the optical system under which the image to reconstruct was acquired. In our previous work, we developed a MATLAB toolbox for accurately calculating realistic vector Fourier-based PSF accounting for any type of aberrations [ arXiv, arXiv:2301.13515 (2023)10.48550/arXiv.2301.13515 ]. In this work, we present a fundamental experimental validation of these numerical methods. The simulated results are found to fit experimental data under different image acquisition conditions at an accuracy higher than 0.97 in normalized cross-correlation. These methods enable a relative contrast of up to 95%.
Studying the nanoscale dynamics of subcellular structures is possible with 2D structured illumination microscopy (SIM). The method allows for acquisition with improved resolution over typical widefield. For 3D samples, the acquisition speed is inherently limited by the need to acquire sequential two-dimensional planes to create a volume. Here, we present a development of multifocus SIM designed to provide high volumetric frame rate by using fast synchronized electro-optical components. We demonstrate the high volumetric imaging capacity of the microscope by recording the dynamics of microtubule and endoplasmatic reticulum in living cells at up to 2.3 super resolution volumes per second for a total volume of 30 × 30 × 1.8 µm3.
We have designed and constructed a 3D microscope that combines Multifocus Microscopy with Structured Illumination Microscopy for live 3D super-resolution biological imaging. Imaging multiple focal planes simultaneously requires a new approach to image reconstruction.
We here report an aberration-corrected 25-plane camera array Multifocus microscope (M25) for high-speed, high-resolution wide-field optical microscopy in three spatial dimensions (3D). We demonstrate live imaging of 25-plane 3D volumes of up to 180×180×50um at >100 volumes per second. 3D data is recorded simultaneously by an array of 25 small, sensitive, synchronized machine-vision cameras. M25 employs aberration-corrected Multifocus microscopy—an optical method where diffractive Fourier optics are used for multiplexing and refocusing light— with a simplified design for chromatic dispersion correction where a corrective diffractive gratings is placed on each camera in the array. This elegant architecture for chromatic correction will be applicable in a broad range of diffractive imaging applications. M25 is a powerful optical tool for high-speed 3D microscopy in that it allows both non-invasive, label-free bright-field and highly sensitive fluorescence microscopy. We showcase M25 capabilities in 3D particle tracking, bright-field, and fluorescence imaging in D. melanogaster , and locomotion and neural activity studies in C. elegans .