5 August 2026 in International Journal of Modern Physics A
1 November 2018 in IEEE Transactions on Nuclear Science
The sPHENIX experiment at the Relativistic Heavy Ion Collider (RHIC) will perform high precision measurements of jets and heavy flavor observables for a wide selection of nuclear collision systems, elucidating the microscopic nature of strongly interacting matter ranging from nucleons to the strongly coupled quark-gluon plasma. A prototype of the sPHENIX calorimeter system was tested at the Fermilab Test Beam Facility as experiment T-1044 in the spring of 2016. The electromagnetic calorimeter (EMCal) prototype is composed of scintillating fibers embedded in a mixture of tungsten powder and epoxy. The hadronic calorimeter (HCal) prototype is composed of tilted steel plates alternating with plastic scintillator. Results of the test beam reveal the energy resolution for electrons in the EMCal is 2.8% ⊕ 15.5%/ √ E and the energy resolution for hadrons in the combined EMCal plus HCal system is 13.5% ⊕ 64.9%/ √ E. These results demonstrate that the performance of the proposed calorimeter system satisfies the sPHENIX specifications.
1 February 1999 in Physical Review C
Directed flow of deuterons, tritons, and is studied in Au+Au collisions at a beam momentum of Flow of all particles is analyzed as a function of transverse momentum for different centralities of the collision. The directed flow signal, is found to increase with particle mass. This mass dependence is strongest in the projectile rapidity region.
13 January 2021 in IEEE Transactions on Nuclear Science
sPHENIX is a new experiment under construction for the Relativistic Heavy Ion Collider at Brookhaven National Laboratory which will study the quark-gluon plasma to further the understanding of quantum chromodynamics (QCP) matter and interactions. A prototype of the sPHENIX electromagnetic calorimeter (EMCal) was tested at the Fermilab Test Beam Facility in Spring 2018 as experiment T-1044. The EMCal prototype corresponds to a solid angle of Δη × Δφ = 0.2 × 0.2 centered at pseudo-rapidity η = 1. The prototype consists of scintillating fibers embedded in a mix of tungsten powder and epoxy. The fibers project back approximately to the center of the sPHENIX detector, giving 2-D projectivity. The energy response of the EMCal prototype was studied as a function of position and input energy. The energy resolution of the EMCal prototype was obtained after applying a position-dependent energy correction and a beam profile correction. Two separate position-dependent corrections were considered. The EMCal energy resolution was found to be σ(E)/〈E〉 = 3.5(0.1) ⊕ 13.3(0.2)/√E based on the hodoscope position-dependent correction, and σ(E)/〈E〉 = 3.0(0.1) ⊕ 15.4(0.3)/√E based on the cluster position-dependent correction. These energy resolution results meet the requirements of the sPHENIX physics program.
6 June 2019 in IEEE Transactions on Nuclear Science
The effects of radiation damage in silicon photomultipliers (SiPMs) from gamma rays have been measured and compared with the damage produced by neutrons. Several types of multipixel photon counters from Hamamatsu were exposed to gamma rays and neutrons at the Solid State Gamma Ray Irradiation Facility (SSGRIF) at the Brookhaven National Laboratory and the Institute for Nuclear Research (Atomki) in Debrecen, Hungary. The gamma ray exposures ranged from 1 krad to 1 Mrad and the neutron exposures ranged from 10 8 to 10 12 n/cm 2 . The main effect of gamma ray damage is an increase in the noise and leakage current in the irradiated devices, similar to what is seen from neutron damage, but the level of damage is considerably less at comparable high levels of exposure. In addition, the damage from gamma rays saturates after a few hundred krad, while the damage from neutrons shows no sign of saturation, suggestive of different damage mechanisms in the two cases. The change in optical absorption in the window material of the SiPMs due to radiation was also measured. This paper was carried out in order to evaluate the use of SiPMs for particle physics applications with moderate levels of radiation exposures.
9 December 2020 in IEEE Transactions on Radiation and Plasma Medical Sciences
Coincidence time resolution (CTR) in modern time-of-flight (TOF) PET scanners is limited by properties of the detector system, namely scintillator size and material, as well as single-photon time resolution (SPTR) and photon detection efficiency of the readout pixels. Recent studies have demonstrated the effectiveness of incorporating depth of interaction (DOI) information into TOF readout to improve CTR. Having multiple timestamps per event has also been shown to improve CTR through leading edge slope estimation. We propose using convolutional neural networks (CNNs) to improve CTR in PET modules with excellent DOI resolution and access to multiple timestamps per event. Monte Carlo simulations were used to generate PET-like data on 4-to-1 coupled single-ended readout depth-encoding modules with 1.5×1.5×20 mm LYSO crystals and prismatoid light guide arrays. We trained our CNN to perform TOF estimation between the 2 simulated modules with and without DOI information, as well as with single and multiple timestamps. The results show using DOI and multiple timestamps provides more than 50% improvement in CTR over standard single timestamp acquisition when sufficient SPTR (<100 ps) is available. Our CNN demonstrates the importance of having multiple timestamps and excellent DOI resolution for improving CTR in practical depth-encoding PET modules.