Hyun Su Lee

Hyun Su Lee

Auto-generated profile, based on publicly available information

Hyun Su Lee

Center for Nanoparticle Research, Institute for Basic Science (IBS), Seoul 08826, Republic of Korea

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 March 2024 in Science Advances
Verified
Journal Article
Open access
YSYoonsoo Shin
Yoonsoo Shin
HLHyun Su Lee
Hyun Su Lee
YHYongseok Joseph Hong
Yongseok Joseph Hong
SSSung-Hyuk Sunwoo
Sung-Hyuk Sunwoo
OPOk Kyu Park
Ok Kyu Park
SLSANGKYU LEE
SANGKYU LEE
Stretchable bioelectronics has notably contributed to the advancement of continuous health monitoring and point-of-care type health care. However, microscale nonconformal contact and locally dehydrated interface limit performance, especially in dynamic environments. Therefore, hydrogels can be a promising interfacial material for the stretchable bioelectronics due to their unique advantages including tissue-like softness, water-rich property, and biocompatibility. However, there are still practical challenges in terms of their electrical performance, material homogeneity, and monolithic integration with stretchable devices. Here, we report the synthesis of a homogeneously conductive polyacrylamide hydrogel with an exceptionally low impedance (~21 ohms) and a reasonably high conductivity (~24 S/cm) by incorporating polyaniline-decorated poly(3,4-ethylenedioxythiophene:polystyrene). We also establish robust adhesion (interfacial toughness: ~296.7 J/m 2 ) and reliable integration between the conductive hydrogel and the stretchable device through on-device polymerization as well as covalent and hydrogen bonding. These strategies enable the fabrication of a stretchable multichannel sensor array for the high-quality on-skin impedance and pH measurements under in vitro and in vivo circumstances.

23 January 2022 in Acta Biomaterialia
Verified
Journal Article
Open access
HLHyun Su Lee
Hyun Su Lee
EJEun Young Jeon
Eun Young Jeon
JNJae Jun Nam
Jae Jun Nam
JPJi Hun Park
Ji Hun Park
ICIn Cheul Choi
In Cheul Choi
YJYoungmee Jung
Youngmee Jung
Peripheral nerve injury causes severe loss of motor and sensory functions, consequently increasing morbidity in affected patients. An autogenous nerve graft is considered the current gold standard for reconstructing nerve defects and recovering lost neurological functions; however, there are certain limitations to this method, such as limited donor nerve supply. With advances in regenerative medicine, recent research has focused on the fabrication of tissue-engineered nerve grafts as promising alternatives to the autogenous nerve grafts. In this study, we designed a nerve guidance conduit using an electrospun poly(lactide-co-ε-caprolactone) (PLCL) membrane with a visible light-crosslinked gelatin hydrogel. The PLCL nanoporous membrane with permeability served as a flexible and non-collapsible epineurium for the nerve conduit; the inner-aligned gelatin hydrogel paths were fabricated via 3D printing and a photocrosslinking system. The resultant gelatin hydrogel with microgrooved surface pattern was established as a conducting guidance path for the effective regeneration of axons and served as a reservoir that can incorporate and release bioactive molecules. From in vivo performance tests using a rat sciatic nerve defect model, our PLCL/gelatin conduit demonstrated successful axonal regeneration, remyelination capacities and facilitated functional recovery. Hence, the PLCL/gelatin conduit developed in this study is a promising substitute for autogenous nerve grafts. STATEMENT OF SIGNIFICANCE: Nerve guidance conduits (NGCs) are developed as promising recovery techniques for bridging peripheral nerve defects. However, there are still technological limitations including differences in the structures and components between natural peripheral nerve and NGCs. In this study, we designed a NGC composed of an electrospun poly(lactide-co-ε-caprolactone) (PLCL) membrane and 3D printed inner gelatin hydrogel to serve as a flexible and non-collapsible epineurium and a conducting guidance path, respectively, to mimic the fascicular structure of the peripheral nerve. In particular, in vitro cell tests clearly showed that gelatin hydrogel could guide the cells and function as a reservoir that incorporate and release nerve growth factor. From in vivo performance tests, our regenerative conduit successfully led to axonal regeneration with effective functional recovery.

3 September 2024 in Biomaterials
Verified
Journal Article
Closed access
YSYoonsoo Shin
Yoonsoo Shin
HLHyun Su Lee
Hyun Su Lee
JKJeong-Uk Kim
Jeong-Uk Kim
YAYoung-Hyeon An
Young-Hyeon An
YKYe-Sol Kim
Ye-Sol Kim
DKDae-Hyeong Kim
Dae-Hyeong Kim

2 January 2026 in Science Advances
Verified
Journal Article
Open access
HLHyun Su Lee
Hyun Su Lee
EJEunyoung Jeong
Eunyoung Jeong
HCHeewon Choi
Heewon Choi
JKJeong-Uk Kim
Jeong-Uk Kim
Nathaniel HwangNathaniel Hwang
Nathaniel Hwang
DKDae-Hyeong Kim
Dae-Hyeong Kim
Establishing stable electrical communication between living tissues and bioelectronic devices requires soft, conductive, and conformable interfaces. Conductive hydrogels are attractive for this role because their hydrated polymer networks and mixed ionic/electronic conductivity reduce impedance and enhance charge transfer. Yet, challenges remain in integrating hydrogels with device components and achieving reliable tissue adhesion. Here, we present a materials and structural design strategy that enables electrically and mechanically robust devices through sequential formation of elastomer-metal-hydrogel multilayers and single-step laser patterning. The device consists of a micropillar-structured waterborne polyurethane substrate with a Au layer strongly bonded to the pillars, showing <2% resistance change under 28% strain. Functional hydrogels provide low interfacial impedance (~36.2 ohms at 1 kilohertz), effective insulation (~51,536 ohms at 1 kilohertz), and strong adhesion (~226 newtons per meter on cardiac tissue). Without elastomer-hydrogel decoupling, performance remains stable under dynamic aqueous conditions. Applied to rodent cardiac tissue, the integrated interface enables real-time electrocardiography monitoring and feedback-controlled electrical stimulation.