Sungho Moon

Sungho Moon

Auto-generated profile, based on publicly available information

Sungho Moon

Nuclear Engineering, Hanyang University, 222, Wangsimni-ro, Seongdong-gu, Seoul, Republic of Korea, Seongdong-gu, 04763, Korea (the Republic of)

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 September 2020 in Journal of Radiological Protection
Verified
Journal Article
Closed access
HHHaegin Han
Haegin Han
YYYeon Soo Yeom
Yeon Soo Yeom
CCChansoo Choi
Chansoo Choi
SMSungho Moon
Sungho Moon
BSBangho Shin
Bangho Shin
CKChan Hyeong Kim
Chan Hyeong Kim
As a geometrical format for computational human phantoms, tetrahedral mesh (TM) is known to have significant advantages over polygonal mesh (PM), including higher compatibility with Monte Carlo radiation transport codes, higher computation speed, and the capability of modeling heterogeneous density variation in an organ of the phantom. In the present study, a computer program named POLY2TET was developed to convert the format of computational human phantoms from PM to TM and generate a sample source code or input file, as applicable, for the converted phantom to be used in some general-purpose Monte Carlo radiation transport codes (i.e. Geant4, PHITS, and MCNP6). The developed program was then tested using four existing high-fidelity PM phantoms. The computation speed, memory requirement, and initialisation time of the generated TM phantoms were also measured and compared with those of the original PM phantoms in Geant4. From the results of our test, it was concluded that the developed program successfully converts PM phantoms into the TM format. The organ doses calculated using the generated TM phantom for the three Monte Carlo codes all produced essentially identical dose values to those for the original PM phantoms in Geant4. The comparison of computation speed showed that compared to the original PM phantoms in Geant4, the TM phantoms in the three Monte Carlo codes were much faster in transporting the particles considered in the present study, i.e. by up to ∼2600 times for electron beams simulated in PHITS. The comparison of the memory requirement showed that the TM phantoms required more memory than the original PM phantoms, but, except for MCNP6, the memory required for the TM phantoms was still less than 12 GB, which typically is available in personal computers these days. For MCNP6, the required memory was much higher, i.e. 60–70 GB.

1 June 2021 in Journal of Radiological Protection
Verified
Journal Article
Closed access
PDF file
CCChansoo Choi
Chansoo Choi
BSBangho Shin
Bangho Shin
YYYeon Soo Yeom
Yeon Soo Yeom
HHHaegin Han
Haegin Han
SHSangseok Ha
Sangseok Ha
WBWesley E Bolch
Wesley E Bolch
In 2016, the International Commission on Radiological Protection (ICRP) launched Task Group 103 (TG 103) for the explicit purpose of developing a new generation of adult and pediatric reference computational phantoms, named ‘mesh-type reference computational phantoms (MRCPs)’, that can overcome the limitations of voxel-type reference computational phantoms (VRCPs) of ICRP Publications 110 and 143 due to their finite voxel resolutions and the nature of voxel geometry. After completing the development of the adult MRCPs, TG 103 has started the development of pediatric MRCPs comprising 10 phantoms (male and female versions of the reference newborn, 1-year-old, 5-year-old, 10-year-old, and 15-year-old). As part of the TG 103 project, within the present study, the skeletal systems, one of the most important and complex organ systems of the body, were developed for each phantom age and sex. The developed skeletal systems, while closely preserving the original bone topology of the pediatric VRCPs, present substantial improvements in the anatomy of complex and/or small bones. In order to investigate the dosimetric impact of the developed skeletons, the average absorbed doses and the specific absorbed fractions for radiosensitive skeletal tissues (i.e. active marrow and bone endosteum) were computed for some selected external and internal exposure cases, which were then compared with those calculated with the skeletons of pediatric VRCPs. The comparison result showed that the dose values of the pediatric MRCPs were generally similar to those of the pediatric VRCPs for highly penetrating radiations (e.g. photons >200 keV); however, for weakly penetrating radiations (e.g. photons ⩽200 keV and electrons), significant differences up to a factor of 140 were observed.

12 December 2024 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
BSBangho Shin
Bangho Shin
SKSuhyeon Kim
Suhyeon Kim
CCChansoo Choi
Chansoo Choi
HKHyeonil Kim
Hyeonil Kim
YYYeon Soo Yeom
Yeon Soo Yeom
CKChan Hyeong Kim
Chan Hyeong Kim
Objective. The International Commission on Radiological Protection (ICRP) decided to develop pregnant-female reference computational phantoms, including the maternal and fetal phantoms, through its 2007 general recommendations. Acknowledging the advantages of the mesh geometry, the ICRP decided to develop the pregnant-female mesh-type reference computational phantoms (MRCPs) for 8, 10, 15, 20, 25, 30, 35, and 38 week fetal ages directly in the mesh format. As part of this process, the present study developed the mesh-type fetal phantoms. Approach. The reference blood-inclusive organ masses, elemental compositions, and densities were established based on various scientific literatures. Then, the phantoms were developed in accordance with the established reference dataset while reflecting the anatomical features of the developing fetus, such as fetal-age-specific anthropometric parameters, bone ossification, and contents formation time. Main results. The phantoms were developed in the tetrahedral-mesh format and can be implemented in the general-purpose Monte Carlo codes (i.e. Geant4, PHITS, MCNP6, and EGSnrc) without the necessity of the voxelization process. To explore the dosimetric impact of the developed phantoms, photon specific absorbed fractions (SAFs) were computed for energies between 10−2–101 MeV for the fetal liver and spleen as source regions and self-irradiation and cross-irradiation to the fetal brain, lungs, and urinary bladder wall as target regions. The SAFs showed the fetal-age-dependent dose trends (i.e. SAF decreases with increasing fetal age) due to organ masses increases via fetal growth. Significance. The mesh-type fetal phantoms, as part of the ICRP pregnant-female MRCPs, will be used to calculate reference dose coefficients for fetal members of the public for both the current and future ICRP general recommendations.

30 September 2021 in Journal of Radiological Protection
Verified
Journal Article
Closed access
PDF file
BSBangho Shin
Bangho Shin
CCChansoo Choi
Chansoo Choi
YYYeon Soo Yeom
Yeon Soo Yeom
HHHaegin Han
Haegin Han
TNThang Tat Nguyen
Thang Tat Nguyen
BCBeom Sun Chung
Beom Sun Chung
For use in electron paramagnetic resonance dosimetry with tooth enamel, in the present study, very detailed mesh-type tooth models composed of 198 individual tooth models (i.e. newborn: 20; 1 year: 28; 5 years: 48; 10 years: 38; 15 years: 32; and adult: 32) were developed for each sex. The developed tooth models were then implanted in the International Commission on Radiological Protection pediatric and adult mesh-type reference computational phantoms and used to calculate tooth enamel doses, by Monte Carlo simulations with Geant4, for external photon exposures in several idealized irradiation geometries. The calculated dose values were then compared to investigate the dependency of the enamel dose on the age and sex of the phantom and the sites of the teeth. The results of the present study generally show that, if the photon energy is low (i.e. 3 MeV, moderate differences were observed (i.e., up to a factor of two), due to the existence of dose build-up in the head of the phantom for high-energy photons. The calculated dose values were also compared with those of the previous studies where voxel and mathematical models were used to calculate the enamel doses. The results again show significant differences at low energies, e.g., up to ∼3500 times at 0.015 MeV, which are mainly due to the differences in the level of tooth-modeling detailedness.

19 August 2022 in Journal of Radiological Protection
Verified
Journal Article
Closed access
CCChansoo Choi
Chansoo Choi
BSBangho Shin
Bangho Shin
YYYeon Soo Yeom
Yeon Soo Yeom
TNThang Tat Nguyen
Thang Tat Nguyen
HHHaegin Han
Haegin Han
BCBeom Sun Chung
Beom Sun Chung
In line with the activities of Task Group 103 under the International Commission on Radiological Protection (ICRP), the present study was conducted to develop a new set of alimentary tract organs consisting of the oral cavity, oesophagus, stomach, small intestine, and colon for the newborn, 1 year-old, 5 year-old, 10 year-old, and 15 year-old males and females for use in the pediatric mesh-type reference computational phantoms (MRCPs). The developed alimentary tract organs of the pediatric MRCPs, while nearly preserving the original topology and shape of those of the pediatric voxel-type reference computational phantoms (VRCPs) of ICRPPublication 143, present considerable anatomical improvement and include all micrometre-scale target and source regions as prescribed in ICRPPublication 100. To investigate the dosimetric impact of the developed alimentary tract organs, organ doses and specific absorbed fractions were computed for certain external exposures to photons and electrons and internal exposures to electrons, respectively, which were then compared with the values computed using the current ICRP models (i.e. pediatric VRCPs and ICRP-100 stylised models). The results showed that for external exposures to penetrating radiations (i.e. photons >0.04 MeV), there was generally good agreement between the compared values, within a 10% difference, except for the oral mucosa. For external exposures to weakly penetrating radiations (i.e. low-energy photons and electrons), there were significant differences, up to a factor of ∼8300, owing to the geometric difference caused by the anatomical enhancement in the MRCPs. For internal exposures of electrons, there were significant differences, the maximum of which reached a factor of ∼73 000. This was attributed not only to the geometric difference but also to the target mass difference caused by the different luminal content mass and organ shape.

2 May 2025 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
BSBangho Shin
Bangho Shin
SKSuhyeon Kim
Suhyeon Kim
CCChansoo Choi
Chansoo Choi
HKHyeonil Kim
Hyeonil Kim
YYYeon Soo Yeom
Yeon Soo Yeom
CKChan Hyeong Kim
Chan Hyeong Kim
Objective. In the present study, the pregnant-female mesh-type reference computational phantoms (MRCPs) of the International Commission on Radiological Protection (ICRP) were fully developed in the tetrahedral-mesh format by constructing the maternal phantoms for 8-, 10-, 15-, 20-, 25-, 30-, 35-, and 38 week fetal ages. Approach. The reference blood-inclusive organ dataset (masses, elemental compositions, and densities) and the anthropometric data (rib cage dimensions, spinal curvature and pelvic inclination angle, breast dimensions, and anthropometric parameters) were established, which were then used to develop the maternal phantoms. During the development process, the pregnant-female MRCPs were fully developed by installing the mesh-type fetal phantoms in the maternal uterus considering the shape and position of the fetus. Main results. The dosimetric impact of the phantoms, in terms of fetal dose from maternal radionuclide intake, was investigated by calculating the photon specific absorbed fractions (SAFs) for some selected maternal organs as source regions and the entire fetal phantom as a target region. The results showed that the SAFs for the older fetus were larger than those for the younger fetus when the source-target distance is long, and the opposite trend is observed when the distance is short. These results were observed due to the growth of the fetus. Significance. The pregnant-female MRCPs will serve as the only ICRP reference phantoms representing the pregnant women and fetuses. The comprehensive SAFs dataset will be computed to calculate the ICRP reference dose coefficients for fetal members of the public.