Yunxu Yang

Yunxu Yang

Auto-generated profile, based on publicly available information

Yunxu Yang

School of Chemistry and Biological Engineering, University of Science and Technology Beijing, Beijing 100083, China

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 August 2017 in Advanced Materials
Verified
Journal Article
Closed access
PDF file
LXLingwei Xue
Lingwei Xue
YYYankang Yang
Yankang Yang
JXJianqiu Xu
Jianqiu Xu
CZChunfeng Zhang
Chunfeng Zhang
HBHaijun Bin
Haijun Bin
JSJinjun Shao
Jinjun Shao

1 April 2017 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
XLXue-Liang Liu
Xue-Liang Liu
Li-Ya NiuLi-Ya Niu
Li-Ya Niu
YCYu-Zhe Chen
Yu-Zhe Chen
YYYunxu Yang
Yunxu Yang
QYQing-Zheng Yang
Qing-Zheng Yang

17 March 2016 in Journal of Materials Chemistry A
Verified
Journal Article
Closed access
PDF file
LXLingwei Xue
Lingwei Xue
YYYankang Yang
Yankang Yang
ZZZhi-Guo Zhang
Zhi-Guo Zhang
XDXinning Dong
Xinning Dong
LGLiang Gao
Liang Gao
JSJinjun Shao
Jinjun Shao
An alternating copolymer (P(IDT-NDI)) containing indacenodithienothiophene (IDT) and naphthalene diimide (NDI) units was synthesized for application as an acceptor material in all-polymer solar cells (all-PSCs). The polymer possesses a low bandgap of 1.51 eV, a suitable LUMO level of −3.84 eV and a HOMO level of −5.75 eV for use as an acceptor material instead of PCBM. Three conjugated polymers including J50 and J51 with a medium bandgap (ca. 1.9 eV) and PTB7-Th with a low bandgap (1.59 eV) were selected as donor materials for the investigation of the photovoltaic performance of the nonfullerene acceptor P(IDT-NDI). The champion all-PSCs with P(IDT-NDI) as an acceptor demonstrated power conversion efficiencies of 3.63%, 4.12% and 5.33% for the polymer donors PTB7-Th, J50 and J51, respectively. The results indicate that the complementary absorption of the polymer donor with polymer acceptor is very important for high performance all-PSCs and P(IDT-NDI) is a promising polymer acceptor for all-PSCs.

4 September 2018 in Journal of Materials Chemistry C
Verified
Journal Article
Closed access
PDF file
MDMan Du
Man Du
BHBaolong Huo
Baolong Huo
Jiemin LiuJiemin Liu
Jiemin Liu
MLMengwen Li
Mengwen Li
ASAo Shen
Ao Shen
YYYunxu Yang
Yunxu Yang
In this paper, a new near-infrared and fluorogenic fluorescent probe (SiR-amide) based on Si-rhodamine for the detection of phosgene is reported. The fast and sensitive phosgene detection was achieved by the conversion reaction of an amide to a nitrile, which resulted in a large fluorescence turn-on response. The response time of SiR-amide to phosgene was 4 min with a detection limit of 8.9 nM in solution. Moreover, easy-to-use paper test strips for fluorescence detection of phosgene gas had also been prepared. All of this work provided a very promising fluorescent probe for rapid, selective and sensitive detection of phosgene both in solution and in the gas phase.

23 December 2016 in Organic & Biomolecular Chemistry
Verified
Journal Article
Closed access
PDF file
XLXue-Liang Liu
Xue-Liang Liu
Li-Ya NiuLi-Ya Niu
Li-Ya Niu
YCYu-Zhe Chen
Yu-Zhe Chen
ZMZheng Meiling
Zheng Meiling
YYYunxu Yang
Yunxu Yang
QYQing-Zheng Yang
Qing-Zheng Yang
We report a fluorescent probe for the selective detection of mitochondrial glutathione (GSH).

19 September 2018 in RSC Advances
Verified
Journal Article
Open access
PDF file
MDMan Du
Man Du
BHBaolong Huo
Baolong Huo
MLMengwen Li
Mengwen Li
ASAo Shen
Ao Shen
XBXue Bai
Xue Bai
YYYunxu Yang
Yunxu Yang
Based on the fluorophore of 2-(2′-hydroxyphenyl)benzothiazole (HBT) with aggregation-induced emission (AIE) properties, a highly selective and sensitive fluorescent probe PBT towards F− was investigated. “Turn-On” fluorescence type signaling was realized by employing fluoride-selective cleavage of the latent thiophosphinated probe in mixed aqueous media. The probe is designed in such a way that the excited state intramolecular proton transfer (ESIPT) of the HBT moiety becomes blocked. The chemodosimetric approach of F− to the probe results in the recovery of the ESIPT by removal of a free AIE-active HBT moiety through a subsequent hydrolysis process. The F− detection limit of the probe was 3.8 nM in the dynamic range of 0.5 μM to 10 μM. In addition, the proposed probe has been used to detect F− in water samples and toothpaste samples with satisfying results.