Priscila Abreu Sperandio

Priscila Abreu Sperandio

Auto-generated profile, based on publicly available information

Priscila Abreu Sperandio

Função Pulmonar e Fisiologia Clínica do Exercício, Divisão de Pneumologia, Universidade Federal de São Paulo, São Paulo (SP) Brasil

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 May 2016 in COPD: Journal of Chronic Obstructive Pulmonary Disease
Verified
Journal Article
Closed access
FAFlavio F. Arbex
Flavio F. Arbex
MAMaria Clara Alencar
Maria Clara Alencar
ASAline Souza
Aline Souza
AMAdriana Mazzuco
Adriana Mazzuco
PSPriscila A. Sperandio
Priscila A. Sperandio
JNJ. Alberto Neder
J. Alberto Neder
Systolic heart failure is a common and disabling co-morbidity of chronic obstructive pulmonary disease (COPD) which may increase exercise ventilation due to heightened neural drive and/or impaired pulmonary gas exchange efficiency. The influence of heart failure on exercise ventilation, however, remains poorly characterized in COPD. In a prospective study, 98 patients with moderate to very severe COPD [41 with coexisting heart failure; ‘overlap’ (left ventricular ejection fraction < 50%)] underwent an incremental cardiopulmonary exercise test (CPET). Compared to COPD, overlap had lower peak exercise capacity despite higher FEV1. Overlap showed lower operating lung volumes, greater ventilatory inefficiency and larger decrements in end-tidal CO2 (PETCO2) (P < 0.05). These results were consistent with those found in FEV1-matched patients. Larger areas under receiver operating characteristic curves to discriminate overlap from COPD were found for ventilation ( E)-CO2 output CO2) intercept, E- CO2 slope, peak E/ CO2 ratio and peak PETCO2. Multiple logistic regression analysis revealed that CO2 intercept ≤ 3.5 L/minute [odds ratios (95% CI) = 7.69 (2.61–22.65), P < 0.001] plus E- CO2 slope ≥ 34 [2.18 (0.73–6.50), P = 0.14] or peak E/ CO2 ratio ≥ 37 [5.35 (1.96–14.59), P = 0.001] plus peak PETCO2 ≤ 31 mmHg [5.73 (1.42–23.15), P = 0.01] were indicative of overlapping. Heart failure increases the ventilatory response to metabolic demand in COPD. Variables reflecting excessive ventilation might prove useful to assist clinical interpretation of CPET responses in COPD patients presenting heart failure as co-morbidity.

9 November 2022 in Jornal Brasileiro de Pneumologia
Verified
Journal Article
Open access
HAHelena Moraes Jardim de Azevedo
Helena Moraes Jardim de Azevedo
NSNataly Winni Fernandes dos Santos
Nataly Winni Fernandes dos Santos
MLMariana Lima Lafeta
Mariana Lima Lafeta
AAAndre Luis Pereira de Albuquerque
Andre Luis Pereira de Albuquerque
SMSuzana Minamoto
Suzana Minamoto
EFEloara V M Ferreira
Eloara V M Ferreira
Many patients hospitalized with COVID-19 were unable to return to work or their return was delayed due to their health condition. The aim of this observational study was to evaluate the impact of moderate-to-severe and critical COVID-19 infection on persistence of symptoms and return to work after hospital discharge. In this study, two thirds of hospitalized patients with pulmonary involvement reported persistence of symptoms six months after COVID-19 infection, such as memory loss (45.5%), myalgia (43.9%), fatigue (39.4%), and dyspnea ( 25.8%), and 50% slowly returned to work, with repercussions due to fatigue and/or loss of energy.

1 January 2020 in Brazilian Journal of Medical and Biological Research
Verified
Journal Article
Open access
PDF file
AMA. Mazzuco
A. Mazzuco
ASA.S. Souza
A.S. Souza
WMW.M. Medeiros
W.M. Medeiros
PSP.A. Sperandio
P.A. Sperandio
MAM.C.N. Alencar
M.C.N. Alencar
ASAudrey Borghi e Silva
Audrey Borghi e Silva
The oxygen uptake (V˙O2) kinetics during onset of and recovery from exercise have been shown to provide valuable parameters regarding functional capacity of both chronic obstructive pulmonary disease (COPD) and chronic heart failure (CHF) patients. To investigate the influence of comorbidity of COPD in patients with CHF with reduced ejection fraction on recovery from submaximal exercise, 9 CHF-COPD male patients and 10 age-, gender-, and left ventricle ejection fraction (LVEF)-matched CHF patients underwent constant-load exercise tests (CLET) at moderate and high loads. The V˙O2, heart rate (HR), and cardiac output (CO) recovery kinetics were determined for the monoexponential relationship between these variables and time. Within-group analysis showed that the recovery time constant of HR (P0.05 in group vs load analysis). The ventilatory efficiency was related to MRT of V˙O2 during high CLET (r=0.71). Our results suggested that the combination of CHF and COPD may further impair the recovery kinetics compared to CHF alone.

15 July 2025 in Jornal Brasileiro de Pneumologia
Verified
Journal Article
Open access
VSVitor Costa Souza1
Vitor Costa Souza1
MSMaria Fernanda Lima Souza Saldanha1
Maria Fernanda Lima Souza Saldanha1
EFEloara V M Ferreira
Eloara V M Ferreira
LNLuiz Eduardo Nery1
Luiz Eduardo Nery1
PSPriscila Cristina de Abreu Sperandio1
Priscila Cristina de Abreu Sperandio1
Objective: To establish reference values and prediction equations for the strength index (S-Index), in order to meet the growing demand for clinical application and diagnostic understanding of maximal dynamic inspiratory pressure. Methods: This was a prospective study of 120 healthy subjects between 18 and 80 years of age. The S-Index, measured from RV to TLC after at least eight reproducible maximal maneuvers with a < 10% difference, was obtained. The MIP was also measured, and differences between S-Index and MIP values were analyzed. A multiple linear regression model estimating the S-Index value was based on clinically significant independent variables. For model cross-validation and diagnostic accuracy, we used a separate sample of COVID-19 survivors to compare the observed and predicted S-Index values. Results: The S-Index strongly correlated with the FEV1 and FVC. However, sex, age, weight, and height retained their significance in all final models, collectively explaining 62% of the variation in the observed values. The performance of the prediction equation was satisfactory in suggesting differences between COVID-19 survivors with an MIP < 80 cmH2O and those with an MIP = 80 cmH2O. For both sexes, the S-Index exhibited the potential for ruling out, rather than confirming, inspiratory muscle weakness. If below the lower limit of normal, further evaluation is important, especially in men. Conclusions: To our knowledge, this is the first set of reference equations for the S-Index based on a healthy adult population across various age groups in Brazil. Its potential as an adjunct index in evaluating inspiratory muscle strength was also explored for the first time.