Alireza Soleimanian

Alireza Soleimanian

Auto-generated profile, based on publicly available information

Alireza Soleimanian

Research Unit of Health Sciences and Technology (HST), Faculty of Medicine, University of Oulu, Oulu, Finland

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2020 in Gene
Verified
Journal Article
Closed access
VEVida Ebrahimi
Vida Ebrahimi
ASAlireza Soleimanian
Alireza Soleimanian
TETahereh Ebrahimi
Tahereh Ebrahimi
RARobab Azargun
Robab Azargun
PYParivar Yazdani
Parivar Yazdani
VTVahideh Tarhriz
Vahideh Tarhriz

1 August 2021 in IEEE Sensors Journal
Verified
Journal Article
Closed access
ASAlireza Soleimanian
Alireza Soleimanian
BKBalal Khalilzadeh
Balal Khalilzadeh
MMMahdi Mahdipour
Mahdi Mahdipour
AAAmir Reza Aref
Amir Reza Aref
AKAlireza Kalbasi
Alireza Kalbasi
MMMajid Mahdavi
Majid Mahdavi
Leukemia stem cells (LSCs) are suitable candidates to be deployed for the diagnosis and therapy of acute myeloid leukemia (AML) patients. In this study, a novel electrochemical cytosensor was designed for the sensitive detection and quantification of KG1a cells as a model of LSCs. The developed cytosensor was based on the overexpression of cell surface protein CD123 by leukemia KG1a cells. For this purpose, the glassy carbon electrode was modified by graphene quantum dots (GQDs), Au nanoparticles, streptavidin coated AuNPs, biotinylated CD123 antibody and target cells. The dense loading of CD123 antibody and electrical enhancement on the modified electrode were carried out using GQDs, this resulting in a sensitive detection of CD123 positive cells within KG1a cells. Step by step preparation of the nanomaterial-based cytosensor and its optimization steps were confirmed by different electrochemical techniques. The field emission scanning electron microscopy (FE-SEM) images also confirmed the proper attachment of the materials and the cells on the surface of the modified electrode. The linear detection range (LDR) and limit of detection (LOD) of the developed electrochemical biosensor were recorded as 1 cell/mL and 1-25 cells/mL, respectively, which is remarkable. Importantly, the present findings are precise and highly selective in the presence of other leukemia cells (NB4, HL60, and U937 cells). Further, the versatility and accuracy of the proposed cytosensor were evaluated using clinical samples. We believe that the cytosensor proposed in this study has the potential to serve as a next generation sensor for the early detection of leukemia stem cells.

1 December 2025 in Nanoscale
Verified
Journal Article
Open access
PDF file
MAMahya Assadipapari
Mahya Assadipapari
ASAlireza Soleimanian
Alireza Soleimanian
MAMax Adam
Max Adam
JLJiali Li
Jiali Li
AYArman Yousefi
Arman Yousefi
CYCuifeng Ying
Cuifeng Ying
This study uses polymer-coated SiN x nanopores and individual-event data analysis to track real time volume and shape changes of ferritin fragments during reassembly and disassembly, offering a powerful method for probing dynamic protein processes.