Model predictive control (MPC) is a model‐based control strategy that introduces many advantages but also some drawbacks. The biggest challenge that faces MPC controller is its sensitivity towards parametric variation. This study aims to robustify MPCs by adding a least mean square (LMS) identification algorithm within their structure. The feasibility of this method is tested on a simple example which is the MPC current control of a permanent magnet synchronous motor driven by a two‐level power converter. Many tests are firstly performed without including inside the MPC algorithms the LMS online tuning procedure. These tests are later compared with the ones obtained with the same control technique but where the identification algorithm is turned on. Results clearly show all the benefits of using this approach on the controller performances.