Adam D. Yock

Adam D. Yock

Auto-generated profile, based on publicly available information

Adam D. Yock

Department of Radiation Oncology, Vanderbilt University Medical Center, Nashville, TN

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 December 2025 in Brain Research
Verified
Journal Article
Open access
AYAdam D. Yock
Adam D. Yock
JBJACQUELYN BROWN
JACQUELYN BROWN
JEJohn Gordon Eley
John Gordon Eley
CLCara Lwin
Cara Lwin
DLDandan Liu
Dandan Liu
JWJohn P. P Wikswo
John P. P Wikswo
This work used an organ-on-a-chip (OOC) model of the blood-brain barrier (BBB) to study effects of clinical radiation on barrier permeability and cytokine concentrations. Gravity-perfused OOC devices developed in house for modeling the BBB were prepared with human endothelial cells, astrocytes, and pericytes. The devices were then irradiated to 0, 2, or 20 Gy with a 6 MV X-ray beam from a medical linear accelerator. At 0, 6, 24, and 48 h post irradiation, barrier permeability was assessed by measuring the diffusion across the barrier of Alexa Fluor-labeled dextran perfused into the vascular chamber. At these same time points, effluent was drawn from both the vascular and brain chambers and analyzed using a 10-cytokine panel. A statistically significant increase in barrier permeability was observed at 24 and 48 h and appeared similar between 2 and 20 Gy. For 20 Gy but not 2 Gy, a large initial increase was observed in the concentration of Granulocyte-Macrophage Colony-Stimulating Factor in the vascular chamber at 6 h, which subsequently decreased. An increase was also observed in the concentration of Interleukin-1α in the brain chamber starting at 24 h and continuing to 48 h. The concentration of Vascular Endothelial Growth Factor was observed to increase starting at 6 h and 24 h in the vascular chamber and brain chamber, respectively, and to subsequently decrease in both chambers. Radiation effects on the BBB including barrier permeability and cytokine concentration can be observed in a dose- and time-dependent manner using an OOC.

6 April 2026 in Practical Radiation Oncology
Verified
Journal Article
Open access
AYAdam D. Yock
Adam D. Yock
ACAnnie Cooney
Annie Cooney
ICIvy Cornelison
Ivy Cornelison
SMSarah Masick
Sarah Masick
DSDennis N. Stanley
Dennis N. Stanley
XRXenia Ray
Xenia Ray
Clinical implementation of online adaptive radiotherapy (ART) requires new quality assurance (QA) methods and equipment. We introduce a novel QA phantom designed to verify online ART treatment planning and delivery through practical, comprehensive end-to-end tests. Furthermore, we present the results of a multi-institutional validation of the phantom applied to CBCT-guided online ART systems. The phantom comprises swappable plastic pieces and features a rigid-yet-reconfigurable design to achieve multiple target morphologies with known geometric relationships. The phantom was circulated among three institutions. Each institution created two treatment plans based on shared dosimetric criteria. For each plan, online ART treatment sessions were conducted and the plans were delivered to the phantom in multiple geometric configurations. Several treatment plan metrics (PTV V100% and D98%; OAR D0.03cc and D2cc) were compared between the original and adaptive plans. Physical dose measurements were made in several locations using either plastic scintillators or an ion chamber, and four sessions were analyzed using film. Lastly, target volumes were contoured repeatedly by three separate users to estimate intra-/inter-user contouring variability. All three institutions used the phantom to test their online ART system's ability to adapt to changing target morphology. Across both plans, changes in target coverage metrics were small (95% of values ≤ 3.3%) and similar between original and adapted plans. However, changes in morphology increased OAR metrics by 20-60 cGy when using the original plan. Adapted plans did not increase dose to the OAR or compromise target coverage. The accurate delivery of the plans was confirmed with > 97% of physical measurements ≤ 5% of their expected value and film gamma rates of 90.7-95.9%. Intra-/inter-user target volume variability was 1.0-1.7% and 1.3-2.4%, respectively. The phantom was successfully used at three separate institutions to verify the entire online ART treatment planning and delivery workflow.