Yuehua Yang

Yuehua Yang

Auto-generated profile, based on publicly available information

Yuehua Yang

Department of Orthopaedics, Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine (originally named Shanghai First People’s Hospital), Shanghai, People’s Republic of China

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2014 in Biochemical and Biophysical Research Communications
Verified
Journal Article
Closed access
YYYuehua Yang
Yuehua Yang
XZXin-Feng Zheng
Xin-Feng Zheng
BLBo Li
Bo Li
SJShengdan Jiang
Shengdan Jiang
LJLeisheng Jiang
Leisheng Jiang

20 November 2013 in European Journal of Orthopaedic Surgery & Traumatology
Verified
Journal Article
Closed access
PDF file
BLBo Li
Bo Li
YYYuehua Yang
Yuehua Yang
LJLei-Sheng Jiang
Lei-Sheng Jiang


4 October 2014 in BMC Musculoskeletal Disorders
Verified
Journal Article
Open access
PDF file
SJShengdan Jiang
Shengdan Jiang
JCJiang-Wei Chen
Jiang-Wei Chen
YYYue-Hua Yang
Yue-Hua Yang
XCXiao-Dong Chen
Xiao-Dong Chen
LJLei-Sheng Jiang
Lei-Sheng Jiang
Diagnosis and treatment decisions of cervical instability are made, in part, based on the clinician’s assessment of sagittal rotation on flexion and extension radiographs. The objective of this study is to evaluate the intraobserver and interobserver reliability of three measurement techniques in assessing cervical sagittal rotation. Fifty lateral radiographs of patients with single-level cervical degenerative disc were selected and measured on two separate occasions by three spine surgeons using three different measurement techniques. Cervical sagittal rotation was measured using three different techniques. Intraclass correlation coefficients were most consistent for Method 2 (ICC 0.93-0.96) followed by Method 1 (ICC 0.88-0.91) and Method 3 (ICC 0.81-0.87). Intraobserver agreement (% of repeated measures within 0.5° of the original measurement) ranged between 76% and 96% for all techniques, with Method 2 showing the best agreement (92%-96%). Paired comparisons between observers varied considerably with interobserver reliability correlation coefficients ranging from 0.54 to 0.89. Method 2 showed the highest interobserver reliability coefficient (0.82, range 0.73-0.88). Method 2 was also more reliable for the classification of “instability”. Intraobserver percent agreements ranged from 94 to 98% for Method 2 versus 84% to 90% for Method 1 and 78% to 86% for Method 3, while interobserver percent agreements ranged from 90% to 98% for Method 2 versus 86% to 94% for Method 1 and 74% to 84% for Method 3. Method 2 (measuring the angle from the inferior endplate of the vertebra above the degenerative disc and the inferior endplate of the vertebra below the degenerative disc) showed the best intraobserver and interobserver reliability overall in assessing cervical sagittal rotation.