Edmara Tatiely Pedroso Bergamo

Edmara Tatiely Pedroso Bergamo

Auto-generated profile, based on publicly available information

Edmara Tatiely Pedroso Bergamo

Department of Biomaterials and Biomimetics, New York University, New York, NY 10010, USA

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 May 2021 in Clinical Implant Dentistry and Related Research
Verified
Journal Article
Open access
PDF file
EBEdmara T. P. Bergamo
Edmara T. P. Bergamo
AZAbbas Zahoui
Abbas Zahoui
RBRaúl Bravo Barrera
Raúl Bravo Barrera
SHSalah Huwais
Salah Huwais
PCPaulo G. Coelho
Paulo G. Coelho
EBEstevam A. Bonfante
Estevam A. Bonfante
Background: Osseodensification (OD) has shown to improve implant stability; however, the influences of implant design, dimensions, and surgical site characteristics are unknown.Purpose: To compare the insertion torque (IT) and temporal implant stability quotients (ISQ) of implants placed via OD or subtractive drilling (SD).Materials and Methods: This multicenter controlled clinical trial enrolled 56 patients, whom were in need of at least 2 implants (n = 150 implants). Patients were treated with narrow, regular, or wide implants and short, regular, or long implants in the anterior or posterior region of the maxilla or in the posterior region of the mandible. Osteotomies were performed following manufacturers recommendation. IT was recorded with a torque indicator. ISQ was recorded with resonance frequency analysis immediately after surgery, 3 and 6 weeks.Results: Data complied as a function of osteotomy indicated significantly higher IT for OD relative to SD. OD outperformed conventional SD for all pairwise comparisons of arches (maxilla and mandible) and areas operated (anterior and posterior), diameters and lengths of the implants, except for short implants. Overall, ISQ data also demonstrated significantly higher values for OD compared to SD regardless of the healing period. Relative to immediate readings, ISQ values significantly decreased at 3 weeks, returning to immediate levels at 6 weeks; however, ISQ values strictly remained above 68 throughout healing time for OD. Data as a function of arch operated and osteotomy, area operated and osteotomy, implant dimensions and osteotomy, also exhibited higher ISQ values for OD relative to SD on pairwise comparisons, except for short implants.Conclusions: OD demonstrated higher IT and temporal ISQ values relative to SD, irrespective of arch and area operated as well as implant design and dimension, with an exception for short implants. Future studies should focus on biomechanical parameters and bone level change evaluation after loading.

7 December 2023 in Materials
Verified
Journal Article
Open access
PDF file
EJErnesto B. B Benalcázar Jalkh
Ernesto B. B Benalcázar Jalkh
EBEdmara T. P. Bergamo
Edmara T. P. Bergamo
TCTiago M. B. Campos
Tiago M. B. Campos
PCPaulo G. Coelho
Paulo G. Coelho
ISIrena Sailer
Irena Sailer
Estevam A. A BonfanteEstevam A. A Bonfante
Estevam A. A Bonfante
Dental zirconias have been broadly utilized in dentistry due to their high mechanical properties and biocompatibility. Although initially introduced in dentistry as an infrastructure material, the high rate of technical complications related to veneered porcelain has led to significant efforts to improve the optical properties of dental zirconias, allowing for its monolithic indication. Modifications in the composition, processing methods/parameters, and the increase in the yttrium content and cubic phase have been presented as viable options to improve zirconias’ translucency. However, concerns regarding the hydrothermal stability of partially stabilized zirconia and the trade-off observed between optical and mechanical properties resulting from the increased cubic content remain issues of concern. While the significant developments in polycrystalline ceramics have led to a wide diversity of zirconia materials with different compositions, properties, and clinical indications, the implementation of strong, esthetic, and sufficiently stable materials for long-span fixed dental prostheses has not been completely achieved. Alternatives, including advanced polycrystalline composites, functionally graded structures, and nanosized zirconia, have been proposed as promising pathways to obtain high-strength, hydrothermally stable biomaterials. Considering the evolution of zirconia ceramics in dentistry, this manuscript aims to present a critical perspective as well as an update to previous classifications of dental restorative ceramics, focusing on polycrystalline ceramics, their properties, indications, and performance.

1 September 2018 in Materials Science and Engineering: C
Verified
Journal Article
Closed access
POPaula Oliveira
Paula Oliveira
EBEdmara T.P. Bergamo
Edmara T.P. Bergamo
RNRodrigo Neiva
Rodrigo Neiva
Estevam A. A BonfanteEstevam A. A Bonfante
Estevam A. A Bonfante
Lukasz WitekLukasz Witek
Lukasz Witek
PCPaulo G. Coelho
Paulo G. Coelho

1 July 2017 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Closed access
DBDimorvan Bordin
Dimorvan Bordin
EBEdmara T.P. Bergamo
Edmara T.P. Bergamo
VFVinicius P. Fardin
Vinicius P. Fardin
PCPaulo G. Coelho
Paulo G. Coelho
Estevam A. A BonfanteEstevam A. A Bonfante
Estevam A. A Bonfante

1 October 2018 in Implant Dentistry
Verified
Journal Article
Closed access
CSCamila E. P. Silva
Camila E. P. Silva
SSSimone Soares
Simone Soares
CMCamila M. Machado
Camila M. Machado
EBEdmara T. P. Bergamo
Edmara T. P. Bergamo
PCPaulo G. Coelho
Paulo G. Coelho
EBEstevam A. Bonfante
Estevam A. Bonfante
To evaluate Ti-Base abutment height and cement type on the retentiveness of zirconia-based restorations. Four millimeter (tall) and 2.5-mm-height (short) abutments along with temporary (provisional), glass ionomer (Meron), self-adhesive (U200), and conventional resin cement (Ultimate) were evaluated using pull-out testing (n = 10 crowns/group). Tall and short abutments demonstrated similar retention for all within cement comparisons, except U200 (P = 0.032). Resin cements exhibited superior retentiveness than others (P < 0.01). Although no significant difference was evidenced between resin cements for short abutments, Ultimate evidenced higher retention than U200 for tall abutments (P = 0.043). Although Ti-Base abutment height has not influenced zirconia superstructures' retentiveness, resin-based cements significantly evidenced higher retention than glass ionomer and temporary cements.

2 July 2018 in Journal of Prosthodontics
Verified
Journal Article
Closed access
PDF file
ALAdolfo Coelho de Oliveira Lopes
Adolfo Coelho de Oliveira Lopes
CMCamila Moreira Machado
Camila Moreira Machado
LBLeonardo Rigoldi Bonjardim
Leonardo Rigoldi Bonjardim
EBEdmara Tatiely Pedroso Bergamo
Edmara Tatiely Pedroso Bergamo
IRIlana Santos Ramalho
Ilana Santos Ramalho
EBEstevam Augusto Bonfante
Estevam Augusto Bonfante