Jorma Keskinen

Jorma Keskinen

Auto-generated profile, based on publicly available information

Jorma Keskinen

Aerosol Physics Laboratory, Physics Unit, Faculty of Engineering and Natural Sciences, Tampere University

Research Focus & Metrics

Academic Career Length

42Years (1985-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 1992 in Journal of Aerosol Science
Verified
Journal Article
Closed access
JKJ. Keskinen
J. Keskinen
KPK. Pietarinen
K. Pietarinen
MLM. Lehtimäki
M. Lehtimäki

1 February 2000 in Journal of Aerosol Science
Verified
Journal Article
Closed access
MMMarko Marjamäki
Marko Marjamäki
JKJorma Keskinen
Jorma Keskinen
DCDa-Ren Chen
Da-Ren Chen
DPDavid Y.H. Pui
David Y.H. Pui

3 July 2017 in Proceedings of the National Academy of Sciences
Verified
Journal Article
Closed access
PDF file
TRTopi Rönkkö
Topi Rönkkö
HKHeino Kuuluvainen
Heino Kuuluvainen
Panu KarjalainenPanu Karjalainen
Panu Karjalainen
JKJorma Keskinen
Jorma Keskinen
RHRisto Hillamo
Risto Hillamo
MMMiikka Dal Maso
Miikka Dal Maso
In densely populated areas, traffic is a significant source of atmospheric aerosol particles. Owing to their small size and complicated chemical and physical characteristics, atmospheric particles resulting from traffic emissions pose a significant risk to human health and also contribute to anthropogenic forcing of climate. Previous research has established that vehicles directly emit primary aerosol particles and also contribute to secondary aerosol particle formation by emitting aerosol precursors. Here, we extend the urban atmospheric aerosol characterization to cover nanocluster aerosol (NCA) particles and show that a major fraction of particles emitted by road transportation are in a previously unmeasured size range of 1.3–3.0 nm. For instance, in a semiurban roadside environment, the NCA represented 20–54% of the total particle concentration in ambient air. The observed NCA concentrations varied significantly depending on the traffic rate and wind direction. The emission factors of NCA for traffic were 2.4·1015 (kgfuel)−1 in a roadside environment, 2.6·1015 (kgfuel)−1 in a street canyon, and 2.9·1015 (kgfuel)−1 in an on-road study throughout Europe. Interestingly, these emissions were not associated with all vehicles. In engine laboratory experiments, the emission factor of exhaust NCA varied from a relatively low value of 1.6·1012 (kgfuel)−1 to a high value of 4.3·1015 (kgfuel)−1. These NCA emissions directly affect particle concentrations and human exposure to nanosized aerosol in urban areas, and potentially may act as nanosized condensation nuclei for the condensation of atmospheric low-volatile organic compounds. Significance We report the significant presence of traffic-originated nanocluster aerosol (NCA) particles in a particle diameter range of 1.3–3.0 nm of urban air, determine the emission factors for the NCA, and evaluate its global importance. Our findings are important because they significantly update the current understanding of atmospheric aerosol in urban areas. They demonstrate that in urban air, extremely small particles form a significant fraction of the total particle number and are a direct result of anthropogenic emissions, that is, the emissions from road traffic. Thus, our findings also imply that in urban areas, an atmospheric nucleation process is not necessary for the formation of a large number of particles that affect population health and climate.

17 August 2007 in Environmental Science & Technology
Verified
Journal Article
Closed access
TRTopi Rönkkö
Topi Rönkkö
AVAnnele Virtanen
Annele Virtanen
JKJonna Kannosto
Jonna Kannosto
JKJorma Keskinen
Jorma Keskinen
MLMaija Lappi
Maija Lappi
LPLiisa Pirjola
Liisa Pirjola

1 March 2014 in Journal of Aerosol Science
Verified
Journal Article
Open access
AJA. Järvinen
A. Järvinen
MAM. Aitomaa
M. Aitomaa
ARA. Rostedt
A. Rostedt
JKJ. Keskinen
J. Keskinen
JYJ. Yli-Ojanperä
J. Yli-Ojanperä
A renewed Electrical Low Pressure Impactor (ELPI+) was introduced by Dekati Ltd. in late 2010. This study presents the collection efficiencies of the ELPI+ cascade impactor stages and the back-up filter as well as the charging efficiency of the corona charger in the size range of 0.01–10μm. According to the measurements the impactor cut diameters are within ±10% to the predecessor except the upmost stage for which the difference was found to be −18%. The secondary collection of nanoparticles was found to be similar to the predecessor for stages with the largest cut diameters but higher for the stages with the smallest cut diameters. The charging efficiency is higher for the new charger compared to the old one by 54% at 20nm particle size. This study also presents the first use of the Single Charged Aerosol Reference (SCAR) for impactor and charger calibrations

1 November 2014 in Atmospheric Environment
Verified
Journal Article
Open access
Panu KarjalainenPanu Karjalainen
Panu Karjalainen
LPLiisa Pirjola
Liisa Pirjola
JHJuha Heikkilä
Juha Heikkilä
TLTero Lähde
Tero Lähde
TTTheodoros Tzamkiozis
Theodoros Tzamkiozis
TRTopi Rönkkö
Topi Rönkkö