Christian Bernhardsson

Christian Bernhardsson

Auto-generated profile, based on publicly available information

Christian Bernhardsson

Lund University

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 September 2008 in Radiation and Environmental Biophysics
Verified
Journal Article
Closed access
PDF file
CBChristian Bernhardsson
Christian Bernhardsson
MCMaria Christiansson
Maria Christiansson
SMSören Mattsson
Sören Mattsson
CRChristopher L. Rääf
Christopher L. Rääf

1 October 2011 in Science of The Total Environment
Verified
Journal Article
Closed access
CBC. Bernhardsson
C. Bernhardsson
IZI. Zvonova
I. Zvonova
CRC. Rääf
C. Rääf
SMS. Mattsson
S. Mattsson

1 December 2017 in Radiation Measurements
Verified
Journal Article
Closed access
VRV. Ramzaev
V. Ramzaev
CBC. Bernhardsson
C. Bernhardsson
ABA. Barkovsky
A. Barkovsky
IRI. Romanovich
I. Romanovich
JJJ. Jarneborn
J. Jarneborn
SGS. Gaponenko
S. Gaponenko


1 December 2012 in Health Physics
Verified
Journal Article
Closed access
CBChristian Bernhardsson
Christian Bernhardsson
SMSvetlana Matskevich
Svetlana Matskevich
SMSören Mattsson
Sören Mattsson
CRChristopher Rääf
Christopher Rääf
Laboratory studies have shown that ordinary household salt (NaCl) exhibits several promising properties for retrospective dosimetry; e.g., a linear dose response and a low detection limit, down to a few mGy or even less. In an attempt to test NaCl as a dosimeter outside the laboratory, the first results from the use of NaCl as a dosimeter under normal environmental conditions are reported here. For this purpose, special dosimeter kits with NaCl and lithium fluoride (LiF) chips were designed. The dosimeter kits were positioned at different locations in a Chernobyl Cs-contaminated village in Belarus during the summers of 2008, 2009, and 2010. The results from the two luminescent detectors were also compared with those of measurements carried out with a handheld 75 cm NaI(Tl) detector and with a 8 dm high pressure ionization chamber. The radiation level in the village was inhomogeneous, and depending on the type of house and countermeasures carried out, the ambient dose rate inside and around the houses varied between 0.05 μSv h and 0.50 μSv h. Based on the different measurements, the annual external effective dose to a hypothetical adult population in the village was estimated as 1-1.5 mSv y. Detector readings from the two luminescent materials correlated relatively strongly to that of the ambient survey NaI(Tl) detector. After three repeated surveys using similar dosimeter kits for prospective dosimetry, the potential use of ordinary household salt as a complement to other techniques for retrospective dose estimations is more evident, and shortcomings of the technique have been identified.

1 May 2021 in Journal of Environmental Radioactivity
Verified
Journal Article
Open access
VRV. Ramzaev
V. Ramzaev
CBC. Bernhardsson
C. Bernhardsson
ADAlexander A. Dvornik
Alexander A. Dvornik
ABA. Barkovsky
A. Barkovsky
AVA. Vodovatov
A. Vodovatov
MJM. Jönsson
M. Jönsson
A new empirical method for in situ determination of the inventory of 137Cs in soil (ACs, kBq m-2) at grasslands and forests using a field-portable NaI(Tl) scintillation spectrometer-dosimeter was developed. The method is based on evaluation of the ambient dose equivalent build-up factor. The practical implementation of the new method with the spectrometer-dosimeter does not require a priori knowledge of the vertical distribution of 137Cs in soil. Moreover, the method allows assessing a value of the mean migration depth of 137Cs in soil (Z) in terms of g cm-2. The 95% confidence interval for the mean value of the conversion coefficients from the ambient dose equivalent build-up factor to ACs and to Z is less than 10%. The new method has been developed and verified using published data that where obtained at territories in Russia and Belarus heavily contaminated with 137Cs (ACs > 37 kBq m-2) due to the Chernobyl accident. Therefore, the survey of less contaminated areas requires additional validation of this method.