Jason Tai Hong Kwan

Jason Tai Hong Kwan

Auto-generated profile, based on publicly available information

Jason Tai Hong Kwan

The University of British Columbia Department of Chemical and Biological Engineering

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 May 2017 in Angewandte Chemie International Edition
Verified
Journal Article
Open access
PDF file
CSCamillo Spoeri
Camillo Spoeri
JKJason Tai Hong Kwan
Jason Tai Hong Kwan
ABArman Bonakdarpour
Arman Bonakdarpour
DWDavid Pentreath Wilkinson
David Pentreath Wilkinson
PSPeter Strasser
Peter Strasser
This Review addresses the technical challenges, scientific basis, recent progress, and outlook with respect to the stability and degradation of catalysts for the oxygen evolution reaction (OER) operating at electrolyzer anodes in acidic environments with an emphasis on ion exchange membrane applications. First, the term “catalyst stability” is clarified, as well as current performance targets, major catalyst degradation mechanisms, and their mitigation strategies. Suitable in situ experimental methods are then evaluated to give insight into catalyst degradation and possible pathways to tune OER catalyst stability. Finally, the importance of identifying universal figures of merit for stability is highlighted, leading to a comprehensive accelerated lifetime test that could yield comparable performance data across different laboratories and catalyst types. The aim of this Review is to help disseminate and stress the important relationships between structure, composition, and stability of OER catalysts under different operating conditions.

1 May 2022 in Journal of the Electrochemical Society
Verified
Journal Article
Open access
PDF file
JKJason Tai Hong Kwan
Jason Tai Hong Kwan
ANAmin Nouri-Khorasani
Amin Nouri-Khorasani
ABArman Bonakdarpour
Arman Bonakdarpour
DMDaniel George McClement
Daniel George McClement
GAGreg Afonso
Greg Afonso
DWDavid P. Wilkinson
David P. Wilkinson
A cross-shaped transparent electrolysis flow cell was designed to simultaneously perform polarization experiments to about 2 A cm−2while monitoring the current response due to bubble formation and detachment. The flow cell was designed in order to accommodate a large electrolyte flow and have flow conditions similar to a PEM electrolyzer. Ir foil experiments using rapid electrochemical cycling techniques were performed first as a quality control measure for cell functionality. Literature quality cyclic voltammograms were obtained, with the anodically formed iridium oxide film growth plateauing after 1000 cycles. The performance of four different Ti current collector meshes were evaluated using a commercial IrO2CCM using 3.5 M H2SO4at 21 ± 0.5°C. The best performing current collector mesh had the largest triple-phase boundary (TPB) length of 56 mm and a porosity of 52%. Using Fourier Transform analysis, the bubble ratios for different current collector and frequency regimes were obtained. The lowest frequency bubble analysis (< 1 Hz) showed the best correlation with the performance of the different meshes.

1 February 2021 in Journal of the Electrochemical Society
Verified
Journal Article
Open access
PDF file
PPPhilip J. Petzoldt
Philip J. Petzoldt
JKJason Tai Hong Kwan
Jason Tai Hong Kwan
ABArman Bonakdarpour
Arman Bonakdarpour
DWDavid Pentreath Wilkinson
David Pentreath Wilkinson
The suitability of the Thin-Film RDE (TF-RDE) technique to rigorously evaluate stability measurements for the oxygen evolution reaction (OER) was recently questioned. The main issue was the inability to deconvolute bubble blockage of catalytic active sites from catalyst dissolution using the TF-RDE technique. It is also possible that the low-loading of TF-RDE OER catalysts exacerbates the effect of bubble blockage. In this work, the modified rotating disk electrode (MRDE) is used with commercial catalyst coated membranes (CCMs) to evaluate catalyst stability. The MRDE may be better suited for stability measurements, since the CCM samples used can better avoid experimental artifacts and can explore much higher current densities than a TF-RDE. Thicker catalyst layers have good adhesion to the membrane, making experimental artifacts less pronounced in stability measurements. Three different stability protocols are used to study the effect of cycling, lower/upper potential limits, and regeneration. The protocol which induced the most irreversible degradation was the square-wave voltammetry (SWV) cycling between 0.05–2.0 VRHE. This irreversible degradation is likely the result of catalyst dissolution. The importance of differentiating between irreversible and reversible degradation is highlighted as a potential future standard for stability evaluation.

27 November 2023 in Journal of Power Sources
Verified
Journal Article
Closed access
JKJason T.H. Kwan
Jason T.H. Kwan
LDLius Daniel
Lius Daniel
WWWillie J. Wang
Willie J. Wang
KYKim L.W. Yao
Kim L.W. Yao
DSDina S. Shehata
Dina S. Shehata
DWDavid Pentreath Wilkinson
David Pentreath Wilkinson

25 August 2022 in Reaction Chemistry & Engineering
Verified
Journal Article
Closed access
PDF file
AGAseem Partap Singh Gill
Aseem Partap Singh Gill
JKJason Tai Hong Kwan
Jason Tai Hong Kwan
DWDavid Pentreath Wilkinson
David Pentreath Wilkinson
Two-step electroless process to form uniform deposition of Ir on Pt at various loadings. Creation of a functional multi-catalyst layer coated membrane (CCM).

13 April 2018 in ECS Meeting Abstracts
Verified
Journal Article
Closed access
JKJason Tai Hong Kwan
Jason Tai Hong Kwan
MKMatthias Kroschel
Matthias Kroschel
ANAmin Nouri-Khorasani
Amin Nouri-Khorasani
ABArman Bonakdarpour
Arman Bonakdarpour
PSPeter Strasser
Peter Strasser
DWDavid P. Wilkinson
David P. Wilkinson
Polymer electrolyte membrane water electrolyzers (PEMWE) are clean and scalable energy conversion devices that can assist with electricity peak shaving and storage by converting electricity into hydrogen as an energy carrier 1. However, performance, durability and cost of these systems still require further improvements before they can be widely adopted. In particular, it is desired to have more efficient and lower cost oxygen evolution reaction (OER) electrocatalysts for the anode, because of the high cost and potential losses that are associated with this electrode2. Screening of catalyst materials, as well other expensive cell components (e.g., Ti current collectors and Ti endplates), is in general a slow and rather expensive process due to the inherent high costs of test cell equipment, and the difficulties associated with cell assembly3. Alternative methods based on commonly available and small laboratory-scale electrochemical test equipment, such as the rotating disk electrode, can facilitate the screening process. We present a novel and economical method for testing electrolysis CCMs and potential current collectors in a rotating electrode (RDE) setup. This method eliminates the difficulties which are often associated with ink preparation and sample drying which are encountered in thin film RDE (TF-RDE) testing. Very recently, we have successfully demonstrated this approach for evaluation of oxygen reduction reaction (ORR) electrocatalysts used in PEMFC applications4. The modified-RDE (MRDE) presented here allows a user to obtain very high current densities (~ 2 A cm-2) which is similar to those normally obtained with PEMWE hardware and test stations (Figure 1). Polarization measurements, kinetic analysis and accelerated degradation tests (ADT) have been performed with a commercial IrO2-based CCM using the MRDE, and are compared with those of PEMWE hardware results. The approach, methodology and the results will be presented at the meeting. References: A. S. Aricò, S. Siracusano, N. Briguglio, V. Baglio, A. Di Blasi, and V. Antonucci, J. Appl. Electrochem., 43, 107–118 (2013). H. Dau, C. Limberg, T. Reier, M. Risch, S. Roggan, and P. Strasser, ChemCatChem, 2, 724–761 (2010). A. S. Lohoff, L. Poggemann, M. Carmo, M. Müller, and D. Stolten, J. Electrochem. Soc., 163, F3153–F3157 (2016) http://jes.ecsdl.org/lookup/doi/10.1149/2.0211611jes. J. T. H. Kwan, A. Bonakdarpour, G. Afonso, and D. P. Wilkinson, Electrochim. Acta, 258, 208–219 (2017) http://linkinghub.elsevier.com/retrieve/pii/S0013468617322090. Figure 1: The effect of different titanium current collector meshes on OER performance using a commercial IrO2-based CCM obtained by the MRDE tool. Inset shows pictures of the different Ti meshes examined. Figure 1