Homa Alemzadeh

Homa Alemzadeh

Auto-generated profile, based on publicly available information

Homa Alemzadeh

University of Virginia

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 April 2016 in PLOS ONE
Verified
Journal Article
Open access
PDF file
HAHoma Alemzadeh
Homa Alemzadeh
JRJaishankar Raman
Jaishankar Raman
NLNancy Leveson
Nancy Leveson
ZKZbigniew Kalbarczyk
Zbigniew Kalbarczyk
RIRavishankar K. Iyer
Ravishankar K. Iyer
Use of robotic systems for minimally invasive surgery has rapidly increased during the last decade. Understanding the causes of adverse events and their impact on patients in robot-assisted surgery will help improve systems and operational practices to avoid incidents in the future. By developing an automated natural language processing tool, we performed a comprehensive analysis of the adverse events reported to the publicly available MAUDE database (maintained by the U.S. Food and Drug Administration) from 2000 to 2013. We determined the number of events reported per procedure and per surgical specialty, the most common types of device malfunctions and their impact on patients, and the potential causes for catastrophic events such as patient injuries and deaths. During the study period, 144 deaths (1.4% of the 10,624 reports), 1,391 patient injuries (13.1%), and 8,061 device malfunctions (75.9%) were reported. The numbers of injury and death events per procedure have stayed relatively constant (mean = 83.4, 95% confidence interval (CI), 74.2–92.7 per 100,000 procedures) over the years. Surgical specialties for which robots are extensively used, such as gynecology and urology, had lower numbers of injuries, deaths, and conversions per procedure than more complex surgeries, such as cardiothoracic and head and neck (106.3 vs. 232.9 per 100,000 procedures, Risk Ratio = 2.2, 95% CI, 1.9–2.6). Device and instrument malfunctions, such as falling of burnt/broken pieces of instruments into the patient (14.7%), electrical arcing of instruments (10.5%), unintended operation of instruments (8.6%), system errors (5%), and video/imaging problems (2.6%), constituted a major part of the reports. Device malfunctions impacted patients in terms of injuries or procedure interruptions. In 1,104 (10.4%) of all the events, the procedure was interrupted to restart the system (3.1%), to convert the procedure to non-robotic techniques (7.3%), or to reschedule it (2.5%). Despite widespread adoption of robotic systems for minimally invasive surgery in the U.S., a non-negligible number of technical difficulties and complications are still being experienced during procedures. Adoption of advanced techniques in design and operation of robotic surgical systems and enhanced mechanisms for adverse event reporting may reduce these preventable incidents in the future.

29 April 2013 in IEEE Security & Privacy
Verified
Journal Article
Closed access
HAHoma Alemzadeh
Homa Alemzadeh
RIRavishankar K. Iyer
Ravishankar K. Iyer
ZKZbigniew Kalbarczyk
Zbigniew Kalbarczyk
JRJai Raman
Jai Raman
Malfunctioning medical devices are one of the leading causes of serious injury and death in the US. Between 2006 and 2011, 5,294 recalls and approximately 1.2 million adverse events were reported to the US Food and Drug Administration (FDA). Almost 23 percent of these recalls were due to computer-related failures, of which approximately 94 percent presented medium to high risk of severe health consequences (such as serious injury or death) to patients. This article investigates the causes of failures in computer-based medical devices and their impact on patients by analyzing human-written descriptions of recalls and adverse event reports obtained from public FDA databases. The authors characterize computer-related failures by deriving fault classes, failure modes, recovery actions, and number of devices affected by the recalls. This analysis is used as a basis for identifying safety issues in life-critical medical devices and providing insights on the future challenges in the design of safety-critical medical devices.

3 October 2016
Verified
Conference Paper
Closed access
HAHoma Alemzadeh
Homa Alemzadeh
DCDaniel Chen
Daniel Chen
XLXiao Li
Xiao Li
TKThenkurussi Kesavadas
Thenkurussi Kesavadas
ZKZbigniew T. Kalbarczyk
Zbigniew T. Kalbarczyk
RIRavishankar K. Iyer
Ravishankar K. Iyer
This paper demonstrates targeted cyber-physical attacks on teleoperated surgical robots. These attacks exploit vulnerabilities in the robot's control system to infer a critical time during surgery to drive injection of malicious control commands to the robot. We show that these attacks can evade the safety checks of the robot, lead to catastrophic consequences in the physical system (e.g., sudden jumps of robotic arms or system's transition to an unwanted halt state), and cause patient injury, robot damage, or system unavailability in the middle of a surgery. We present a model-based analysis framework that can estimate the consequences of control commands through real-time computation of robot's dynamics. Our experiments on the RAVEN II robot demonstrate that this framework can detect and mitigate the malicious commands before they manifest in the physical system with an average accuracy of 90%.

6 February 2023 in IEEE Transactions on Dependable and Secure Computing
Verified
Journal Article
Closed access
XZXugui Zhou
Xugui Zhou
BABulbul Ahmed
Bulbul Ahmed
JAJames H. Aylor
James H. Aylor
PAPhilip Asare
Philip Asare
HAHoma Alemzadeh
Homa Alemzadeh
Recent advances in sensing and computing technology have led to the proliferation of Cyber-Physical Systems (CPS) in safety-critical domains. However, the increasing device complexity, shrinking technology sizes, and shorter time to market have resulted in significant challenges in ensuring the reliability, safety, and security of CPS. This paper presents a hybrid knowledge and data-driven approach for designing run-time context-aware safety monitors that can detect early signs of hazards and mitigate them in CPS. We propose a framework for formal specification of unsafe system context using Signal Temporal Logic (STL) combined with two optimization approaches for scenario-specific refinement and integration of STL specifications using data collected from closed-loop CPS simulations. We demonstrate the effectiveness of our approach in simulation using an autonomous driving system (ADS) and two closed-loop artificial pancreas systems (APS) as well as a publicly-available clinical trial dataset. The results show that a safety monitor developed with the proposed approaches demonstrates up to 4.7 times increase in average prediction accuracy (F1 score) over several well-designed baseline monitors while reducing both false-positive and false-negative rates in most scenarios.

1 July 2008
Verified
Conference Paper
Closed access
FRFatemeh Refan
Fatemeh Refan
HAHoma Alemzadeh
Homa Alemzadeh
SSSaeed Safari
Saeed Safari
PPPaolo Prinetto
Paolo Prinetto
ZNZainalabedin Navabi
Zainalabedin Navabi
Networks on chips (NoCs) provide a mechanism for handling complex communications in the next generation of integrated circuits. At the same time, lower yield in nano-technology, makes self repair communication channels a necessity in design of digital systems. This paper proposes a reliable NoC architecture based on specific application mapped onto an NoC. This architecture is capable of recovering from permanent switch failures via replacing them by neighboring switches. This method has hardware and power consumption overhead, but significantly improves reliability and has a very little effect on the performance of the system. We suggest a reliability analysis method based on the combinatorial reliability models and use it to evaluate our proposed fault-tolerant NoC architecture.

25 November 2015 in Lecture Notes in Computer Science
Verified
Book Chapter
Open access
PDF file
HAHoma Alemzadeh
Homa Alemzadeh
DCDaniel Chen
Daniel Chen
ALAndrew Lewis
Andrew Lewis
ZKZbigniew Kalbarczyk
Zbigniew Kalbarczyk
JRJaishankar Raman
Jaishankar Raman
RIRavishankar Iyer
Ravishankar Iyer
Robotic surgical systems are among the most complex medical cyber-physical systems on the market. Despite significant improvements in design of those systems through the years, there have been ongoing occurrences of safety incidents that negatively impact patients during procedures. This paper presents an approach for systems-theoretic safety assessment of robotic telesurgical systems using software-implemented fault injection. We used a systems-theoretic hazard analysis technique (STPA) to identify the potential safety hazard scenarios and their contributing causes in RAVEN II, an open-source telerobotic surgical platform. We integrated the robot control software with a software-implemented fault injection engine that measures the resilience of system to the identified hazard scenarios by automatically inserting faults into different parts of the software. Representative hazard scenarios from real robotic surgery incidents reported to the U.S. Food and Drug Administration (FDA) MAUDE database were used to demonstrate the feasibility of the proposed approach for safety-based design of robotic telesurgical systems.