This paper proposes a self-powered disposable supply-sensing biosensor platform for big-data-based healthcare applications. The proposed supply-sensing biosensor platform is based on bio fuel cells and a 0.23-V 0.25-μm zero-V th all-digital CMOS supply-controlled ring oscillator with a current-driven pulse-interval-modulated inductive-coupling transmitter. The fully digital, and current-driven architecture uses zero-V th transistors, which enables low voltage operation and a small footprint, even in a cost-competitive legacy CMOS. This enables converterless self-powered operation using a bio fuel cell, which is ideal for disposable healthcare applications. To verify the effectiveness of the proposed platform, a test chip was fabricated using 0.25-μm CMOS technology. The experimental results successfully demonstrate operation with a 0.23-V supply, which is the lowest supply voltage reported for proximity transmitters. A self-powered biosensing operation using organic bio fuel cells was also successfully demonstrated. In addition, an asynchronous inductive-coupling receiver and an off-chip inductor for performance improvement were successfully demonstrated.
23 October 2017 in IEEE Transactions on Biomedical Circuits and Systems
In this paper, we present a self-powered bio-sensing system with the capability of proximity inductive-coupling communication for supply sensing and temperature monitoring. The proposed bio-sensing system includes a biofuel cell as a power source and a sensing frontend that is associated with the CMOS integrated supply-sensing sensor. The sensor consists of a digital-based gate leakage timer, a supply-insensitive time-domain temperature sensor, and a current-driven inductive-coupling transmitter and achieves low-voltage operation. The timer converts the output voltage from a biofuel cell to frequency. The temperature sensor provides a pulse width modulation (PWM) output that is not dependent on the supply voltage, and the associated inductive-coupling transmitter enables proximity communication. A test chip was fabricated in 65 nm CMOS technology and consumed 53 μW with a supply voltage of 190 mV. The low-voltage-friendly design satisfied the performance targets of each integrated sensor without any trimming. The chips allowed us to successfully demonstrate proximity communication with an asynchronous receiver, and the measurement results show the potential for self-powered operation using biofuel cells. The analysis and experimental verification of the system confirmed their robustness.
27 July 2018 in IEEE Transactions on Circuits and Systems II: Express Briefs
This work presents the lowest-current fully-integrated sub-mm³ OOK transmitter, the transmission of which is modulated by its supply voltage. By combining the transmitter with a glucose fuel cell which functions as both the power source and sensing transducer, a self-powered CGMS contact lens can be emerged. The prototype in 55-nm deeply depleted channel (DDC) CMOS with on-chip inductor and antenna requires an average current of 6.1 nA under 0.32-V supply without any external signal, which demonstrates the potential of self-powered operation.
20 November 2018 in IEEE Transactions on Biomedical Circuits and Systems
A fully integrated CMOS circuit based on a vector network analyzer and a transmission-line-based detection window for circulating tumor cell (CTC) and exosome analysis is presented for the first time. We have introduced a fully integrated architecture, which eliminates the undesired parasitic components and enables high-sensitivity, to analyze extremely low-concentration CTC in blood. The detection window was designed on the high-sensitive coplanar waveguide line. To validate the operation of the proposed system, a test chip was fabricated using 65-nm CMOS technology. Measurements were performed after adding a tiny lump of silicone or a droplet of water on its detection window. The measured results show |S_21| degradation of -1.96 dB and -6.04 dB for the silicone and the droplet, respectively, at 1.4 GHz. In addition, in another measurement using magnetic beads, it is confirmed that the proposed circuit can analyze even low concentrations of 20 beads/μL. As well as microbeads, measurement with CTCs was successfully demonstrated.
7 July 2020 in IEEE Open Journal of Circuits and Systems
Energy-efficient timer circuits are required in numerous applications for periodic operations, such as performing measurements and communicating data. In this paper, we present a gate-leakage-based timer that utilizes an amplifier-less replica-bias switching technique to generate a stable frequency, which can operate at a low supply voltage. To guarantee a stable oscillation frequency in a small circuit area, the proposed design adopts an architecture that discharges a pre-charged capacitor through a resistive element (gate-leaking MOS capacitor) with a low-leakage switch. In the proposed switching technique, the low-voltage timer operates by tracking the discharging terminal of the capacitor and biasing the reference voltages of two switch units, thereby enabling the minimization of the leakage current without the need for analog amplifier circuits. The high supply sensitivity of the timer is addressed by regulating the supply voltage using a native NMOS header (NNH). The proposed design is fabricated using the 55-nm deeply depleted channel (DDC) CMOS technology, which has a strong body coefficient and occupies an active circuit area of 0.0022 mm2. The measurements show that the proposed design can achieve an energy-per-cycle value of 25 pJ/cycle at a supply voltage of 350 mV when body biasing is applied. The measured Allan deviation floor is 200 ppm at room temperature. The timer exhibits an average temperature sensitivity of 810 ppm/∘C for four samples. Moreover, a reduction in the supply sensitivity by a factor of 26 using the NNH is demonstrated in an active circuit area of 0.0034 mm2.
30 October 2019 in IEEE Transactions on Biomedical Circuits and Systems
A supply voltage monitor (SVM) with self-controlled dual-oscillator-based architecture is proposed herein for biosensing systems combined with a biofuel cell (BFC) in this paper. The output of the BFCs can be used to monitor the biological signals while powering the BFC-combined biosensing systems. Thus, the SVM is designed to convert the change in the supply voltage (V DD) into a code. The architecture of the proposed SVM allows self-controlled periodic operation without external signals. Furthermore, the frequency subtraction technique that uses two oscillators employing gate-leakage-based architecture with different frequency sensitivities to V DD allows accurate code generation with low power consumption and a small circuit area for supply voltage monitoring. The proposed SVM is fabricated using two different CMOS process technologies, including 65-nm CMOS and 55-nm deeply depleted channel (DDC) CMOS. The implementation of the 65-nm CMOS obtains an operating V DD range of 250 mV (0.75-1 V), draws a standby power consumption of 1.4 nW at 0.75-V V DD, exhibits a resolution of 2.4 mV with a nonlinearity error of -8.4/ +12.1 mV, and occupies a circuit area of 0.0047 mm2. Meanwhile, the implementation of the 55-nm DDC CMOS for low-voltage operation achieves an operating V DD range of 300 mV (0.225-0.525 V), draws a standby power consumption of 32.5 nW at 0.25-V V DD, exhibits a resolution of 0.94 mV with a nonlinearity error of -15.2/ +14 mV, and occupies a circuit area of 0.0032 mm2.